18
BATTERY REPLACEMENT
The meter is powered by a two 1.5V battery. Refer to Figure 2 and use the following procedure to replace the
battery:
1. Disconnect the test leads and turn the meter off. Remove the test leads from the input terminals.
2. Position the meter face down. Remove the screw from the case bottom.
3. Lift the end of the case bottom until it gently unsnaps from the case top at the end nearest the input terminal.
4. Lift the battery from the battery box.
5. Fit the new battery into the battery box.
6. Replace the case top and case bottom. Reinstall the screw.
Содержание IDM63N
Страница 1: ...INSTRUCTION MANUAL IDM63N DIGITAL MULTIMETER EN IT DE FR...
Страница 2: ...1 ISO TECH IDM 63N DIGITAL MULTIMETER INSTRUCTION MANUAL...
Страница 3: ...2...
Страница 6: ...5 Figure 1...
Страница 20: ...19 BATTERY REPLACEMENT Figure 2 Case Bottom Case Top Battery Connector 1 5V x 2 Battery Battery Box...
Страница 21: ...20 HOW TO USE THE PROBE HOLDER Slide out one probe holder for one handed meter operation...
Страница 22: ...21 HOW TO USE THE PROBE HOLDER Wrap the leads around the holster to store the test probes...