background image

ITA / ITB Series Weighing Scales

2

ITA / ITB Series Weighing Scales

7

c.

Gently  place  the  weights  on  weighing  pan  and  weight  should  not  be  more 
than the scale capacity.

d.

Do  not  allow  the  weight  to  remain  on  the  scale  for  long  time  than  the  time
required/or weighment

e.

The  scale  is  programmed  for  9e  steps  plus  scale  capacity  before  it  Table  Top
overload.

f. 

Battery must be used once in a week for long term better performance.

g.

Use always your fingers to operate the keys.

h.

The  scale  should  be  cleaned  regularly  with  a  soft  cloth  or  brush.  Mild  cleaning
agent  should  be  used  to  remove  the  dirt  and  stubborn  grime.  Never  place  and
handle the scale inwet condition.

i.

Spilageduring'weighmg process should be removed immediately.

j.

Never hit the pan and overload the scale.

k.

The  scale  should  be  cleaned  in  its  normal  condition.  The  load  cell  may  get
damaged if the scale is tilted on ifs side or is kepi upside down.

1.

For appropriate display clarity the indicator should not placed in direct sunlight, and
must  be  placed  on  a  sturdy  platform.  Heavy  vibration  and  highly  dusty  area  also
seriously effect the life of the Table Top.

BATTERY :

The  Scale  uses  a  6V  Sealed  lead  acid  rechargeable  Battery.  The  user  must  make
sure  to  connect  the  battery  correctly,  that  is  the  RED  wire  should  be  attached  to  the
RED (+) end of the battery and the BLACK. wire should be attached to the BLACK (-)
end  of  the  battery.  Wrong  connections  can  damage  the  battery  and  the  Scale  beyond
repairs, so be very careful while making the connections.
Also note:

l

Please charge the battery for at least 20 hours before using the Scale for the.
first time.

l

The  battery  automatically  gets  charging  once  the  Scale  power  cable  is

plugged  in  to  the  mains;  hence  only  make  sure  that  the  RED  LED  on  the  top
right side of the display is ON.

l

 If the scale is not used for long, the battery will discharge under self leakage, and

hence should be charged from time to time. Ideally the battery should be charged
for at least 10 to 12 hours every two months to prolong the battery life.

MAINTENANCE:

Please note the following points of care for the Scale to prolong it life:

l

 Make sure to turn off the power while installing or removing the power cable of

the Scale from the mains supply.

l

  Make  sure  to  switch  of  the  Scale  while  connecting  or  removing  the  loadcell

connector.

l

  Make  sure  that  the  loadcell  connector  is  properly  connected  to  the  Scale  and

secured with the screws provided with the connector.

"RNG  03  ":  Follow  the  above  procedure,  only  remember  that  you  have  to  enter  the
DIV,  DECIMAL  and  CAP  thrice  instead  of  once  or  twice.  The  maximum  number  of
counts  allowed  for  each  capacity  range  will  be  10000  counts  or  less,  and  hence  the
setting should be entered accordingly.

NOTE: Please make sure thai for "RNG 02 " and "RNG 03 ", the lower DIV and CAP is 
entered first,and then the higher DiV and CAP.

External Calibration Settings (Without Division, Decimal and Capacity setting):

Press  the  ZERO  key  and  switch  on  the  scale.  The  display  will  show  "PASS"  and
then  "000000  ".Press  the  ZERO  key  The  display  will  show  "CAL".  Press  the  ZERO
the  display  will  briefly  show  "no  Load  "  and  then  the  internal  division  at  no  load
condition.  Make  sure  for  the  decimal  point  to  stop  blinking,  and  then  press  the  ZERO
Button. The display will show "LOAD " briefly and then again the internal counts. Keep
the  calibration  weight  and  press  the  ZERO  key  the  display  will  show  "000000  ".
Now  enter  the  value  of  the  calibration  weight  kept  using  the  MODE  and  PCS  Key/
Finally  press  the  ZERO  key  the  display  will  show  the  calibrated  weight.  If  the
difference  between  this  external  calibration  and  the  previous  internal  calibration  is
more  than  5%.  the  new  calibration  will  not  be  stored  and  the  Scale  will  pick  up  the
values/setting  according  to  the  old  internal  calibration  only.  If  the  user  feels  that  the
new  external  calibration  is  correct  and  still  the  Scale  is  not  accepting  it,  then  the
correct way to do the calibration will be to do the internal calibration again.

Содержание K9 Series

Страница 1: ...ITA ITB Series Weighing Scales ITA ITB Series Weighing Scales Sales Service Network Scale Users Guide K9 Series ISHTAA SCALES INC INDIA www ishtaascales com Hubli Nagapattinam Alapuzha ...

Страница 2: ...come to Ishtaa Scales Congratulations on your purchase of ISHTAA Electronic Weighing Scales You have chosen Right Brand to weigh your materials accurately always Every care has been taken during manufacturing to get better accuracy always UNPACKING Unpack the scale carefully and save the packing materials for future Transportation use if required Confirm the contents of the packing as per your ord...

Страница 3: ... charged from time to time Ideally the battery should be charged foratleast10to12hours everytwomonths toprolongthebatterylife MAINTENANCE PleasenotethefollowingpointsofcarefortheScaletoprolongitlife l Make sure to turn off the power while installing or removing the power cable of theScalefrom themains supply l Make sure to switch of the Scale while connecting or removing the loadcell connector l M...

Страница 4: ...he on off switch at the bottom of the Scale The display will show Start up message and Version no of the software andthendisplay 0 00 KEYS CONTROLS Z T This key is used to zero an unwanted reading on the display This isalso usedforgoingintothecalibrationmode Hold This keyisusedfor holdingtheweightonthedisplay Mode This key is used for Setting the LOW and HIGH LIMIT in the scale Thekeyisalso usedas...

Страница 5: ...e as 0 00 the Scale will sound the beep sound below the SETLO value SET HI value is entered only If the user only enters the SET HI value and keep the SET LO value as 0 00 the Scale will sound the beep sound above the SETHI value SET LO SET HI both are entered If the user enter both SET LO and SET HI value the beep will not sound below between the SET LO and SET HI value range and thebeepwillsound...

Отзывы: