28
IWQ Operation Manual Kg Version
Manual No. 0142A
Set No.
Setup title
Set value
Functions
F08
Selecting chit type single/
consecutive
00
Single chit
01
Consecutive chit
F09
Band rate
00
1200 bps
01
2400 bps
02
4800 bps
03
9600 bps
04
19200 bps
05
38400 bps
F10
Selecting serial output for-
mat
00
Specifically designed for printer
01
DAP-01 format
02
IWQ1 format (DAP-01 expanded)
03
MZ-7000 format
04
IWQ2 format (MZ-7000 expanded)
F11
Serial output method
00
No output
01
Send-out in discharge (synchronous to A/D)
02
Output conditions (F12)
03
As requested for DATA input (RS input) (contact
input)
F12
Serial output conditions
00
Output when automatic/within range/re-stabilize
01
Output when manual/within range/re-stabilize
02
Output when automatic/range disregarded/re-stabilize
03
Output when manual/range disregarded/re-stabilize
04
Output when automatic/within range/zero return
05
Output when manual/within range/zero return
06
Output when automatic/range disregarded/zero return
07
Output when manual/range disregarded/zero return
- When “Send-out in discharge” is set, the O8 command is not
available.
- When manual printing is set, key input is determined to be error
for a unstable state.