3
General information
3-1 Time setting
Lubrication time: orange light on, unit second.
Intermittent time: green light on, unit minute.
Please turn off the power before time setting. Remove the cover cap, there are two
sets of switches on the circuit board, the upper one is for lubrication time, the lower one
is for intermittent time. According to the time setting table(inside the cover cap) set the
time. Please confirm and put the cover cap back after setting.
Warning!intermittent time must be more than 5 times of the lubrication time.
!If lubrication is required at the interval, you may press FEED button to discharge oil.
!Disconnect the product from main power supply before working on it. Don’t reboot in
20sec.
!The elbow adapter on the lubrication unit is specified. Never change it by yourself.