background image

Important safety instructions

WARNING!

WARNING!

To avoid injury of users it is not allowed to open the unit. There are no parts which can be maintained by users 
inside of the unit. Opening the unit will void the warranty.

WARNING!

WARNING!

The high-voltage cable must be professionally connected to the consumer/load and the connection insulated 
with the appropriate dielectric strength. Do not power the consumer/load outside of its specified range.

WARNING!

WARNING!

Before connecting or disconnecting HV cables or any operation on the HV output or the application, the unit has
to be switched off and discharge of residual voltage has to be finished. Depending on application residual 
voltages can be present for long time periods.

WARNING!

WARNING!

Do not operate the unit in wet or damp conditions.

WARNING!

WARNING!

Do not operate the unit in an explosive atmosphere.

WARNING!

WARNING!

Do not operate the unit if you suspect the unit or the connected equipment to be damaged.

EDS High Voltage Power Supply series | Last changed on: 17.06.2020 | 

www.iseg-hv.com

5/21

Содержание EDS LOW COST

Страница 1: ... Voltage Module with Common Floating Ground 16 24 48 channel 1kV 3 kV versions Low cost version with reduced current measurement accuracy very low ripple and noise hardware voltage and current limit voltage control and current measurement per channel programmable parameters www iseg hv com ...

Страница 2: ...Rights Reserved This document is under copyright of iseg Spezialelektronik GmbH Germany It is forbidden to copy extract parts duplicate for any kind of publication without a written permission of iseg Spezialelektronik GmbH This information has been prepared for assisting operation and maintenance personnel to enable efficient use The information in this manual is subject to change without notice ...

Страница 3: ...ty instructions DANGER DANGER Danger indicates a severe injury hazard The non observance of safety instructions marked as Danger will lead to possible injury or death WARNING WARNING Warning indicates an injury hazard The non observance of safety instructions marked as Warning could lead to possible injury or death CAUTION CAUTION Advices marked as Caution describe actions to avoid possible damage...

Страница 4: ... on the basis of his technical training his knowledge and experience as well as his knowledge of the relevant regulations General safety instructions Observe the valid regulations for accident prevention and environmental protection Observe the safety regulations of the country in which the product is used Observe the technical data and environmental conditions specified in the product documentati...

Страница 5: ... its specified range WARNING WARNING Before connecting or disconnecting HV cables or any operation on the HV output or the application the unit has to be switched off and discharge of residual voltage has to be finished Depending on application residual voltages can be present for long time periods WARNING WARNING Do not operate the unit in wet or damp conditions WARNING WARNING Do not operate the...

Страница 6: ...penings is possible CAUTION Caution When controlling with software the high voltage systems make sure that nobody is near the high voltage or can be injured INFORMATION INFORMATION Please check the compatibility with the devices used EDS High Voltage Power Supply series Last changed on 17 06 2020 www iseg hv com 6 21 ...

Страница 7: ...nection 11 3 2 Module status 12 3 3 Hardware Limit 12 3 4 Safety Loop 12 3 5 Delayed Trip 13 4 Options 13 4 1 SLA Active safety loop 13 4 2 SLP Internally powered safety loop 13 5 Front panel versions 14 6 Dimensional Drawings 15 7 Connectors and PIN assignments 17 8 Accesories 18 9 Order guides 18 10 Appendix 19 11 Glossary 20 12 Warranty service 21 13 Disposal 21 14 Manufacturer contact 21 EDS H...

Страница 8: ...nt measurement EDS supplies come with common floating ground to reduce the voltage noise level With up to 48 channels each single channel has an independent voltage control The modules are made of high precision components such as 24 bit ADC and 20 bit DAC and provide comprehensive security features By offering different configurations and options this module perfectly covers various types of appl...

Страница 9: ...0 6 Vnom Resolution voltage measurement 1 2 10 6 Vnom Resolution current measurement 1 1 10 4 Inom 5 10 4 Inom Measurement accuracy The measurement accuracy is guaranteed in the range 1 Vnom Vout Vnom and for 1 year Accuracy voltage measurement 0 01 Vout 0 02 Vnom Accuracy current measurement 0 1 Iout 0 1 Inom 1 Iout 1 Inom Sample rates ADC SPS 5 10 25 50 60 100 500 2 Digital filter averages 1 16 ...

Страница 10: ...1 kV 1 mA 48 5 2 R51 46 ED48y010x1050004300 SLA SLP EDS F1 30x 3 kV 500 µA 16 1 7 R51 46 ED161030x5040004300 SLA SLP EDS 18y 30x 3 kV 500 µA 24 2 6 R51 46 ED24y030x5040004300 SLA SLP EDS 30y 30x 3 kV 500 µA 48 5 2 R51 46 ED48ys030x5040004300 SLA SLP Notes 16 channel modules in standard only Table 2 Technical data Configurations of EDS series OPTIONS OPTION CODE EXAMPLE ITEM CODE HEX CODING POLARIT...

Страница 11: ...ate controller the module will be used with The delivery condition is shown on the modules typeplate side plate of the module Typically newer iseg crate controllers CC24 CC23 CC238 are delivered with 250 kBits s standard Wiener M POD Controller and older iseg hardware is set on 125 kBit s standard bitrate INFORMATION INFORMATION EDS modules with Common Floating Ground CFG will be delivered with a ...

Страница 12: ... 2 Inom The output voltage is limited to the specified value If the current exceeds the hardware current limit about 30 above the current limit value set by the limit potentiometer the channel will be shut off without delay and ramp In both cases the green LED on the front panel turns off 3 4 Safety Loop A safety loop can be implemented by the safety loop socket SL on the front panel and between t...

Страница 13: ... the channel will be shut off without delay and ramp If the Delayed Trip function is activated the voltage ramp should be limited to 1 of Vnom before Higher values could trigger a trip by internal charge balancing during a ramp even though the output current does not exceed the set value Iset If the connected load contains capacities or if Iset is very small it might be necessary to further reduce...

Страница 14: ...panel versions FRONT PANELS Channels 16 24 48 Floating CFG CFG HV Connector SHV S08 R51 Figure Table 5 Front panel versions EDS High Voltage Power Supply series Last changed on 17 06 2020 www iseg hv com 14 21 ...

Страница 15: ...6 Dimensional Drawings Figure 2 Dimensional Drawing ex R51 EDS High Voltage Power Supply series Last changed on 17 06 2020 www iseg hv com 15 21 ...

Страница 16: ...Figure 3 Dimensional Drawing ex SHV EDS High Voltage Power Supply series Last changed on 17 06 2020 www iseg hv com 16 21 ...

Страница 17: ...nector contacts female ERA 05 403 ZLL1 Z592263 Contacts Safety Loop male FGG 2B 565 ZZC Z592261 Contacts Safety Loop female EGG 3B 665 ZZM Z592262 Socket Load Side SLA H51 LLZBG Z201035 SHV ROSENBERGER Socket 57S501 200N3 Connector 57K101 006N3 Z590162 S08 RADIALL Socket R317 580 000 Connector R317 005 000 Z592474 Safety Loop LEMO Socket ERA 0S 302 CLL Connector FFA 0S 302 CLAC Z592312 Limit monit...

Страница 18: ...1 46 G 08 HV cable 6kV Kerpen SL v2YCeHI 56xAWG26 7red R51 46 A RG46_C07 LLL_RA46 SHV 04 HV cable shielded 30kV HTV 30S 22 2 open SHV_C04 LLL Notes 1 Length building examples 10cm 0 1 2 5m 2 5 12m 012 999m 999 Table 8 Guideline for cable ordering CONFIGURATION ORDER GUIDE item code parts ED 48 1 030 P 504 000 02 00 High Voltage Distributor Numbers of channels Class Vnom Polarity Inom nA Option hex...

Страница 19: ...S MMS EDS iseg_datasheet_EDS_en pdf CAN EDCP Programmers Guide http download iseg hv com SYSTEMS MMS CAN_EDCP_Programmers Guide pdf iseg Hardware Abstraction Layer http download iseg hv com SYSTEMS MMS isegHardwareAbstractionLayer pdf EDS High Voltage Power Supply series Last changed on 17 06 2020 www iseg hv com 19 21 ...

Страница 20: ... Inom nominal output current Iout output current Iset set value of output current Imon monitor voltage of output current Imeas digital measured value of current Itrip current limit to shut down the output voltage Iin input supply current Imax limit max value of output current Ilimit Current Limit Ibounds Current bounds a tolerance tube Iset Ibounds around Iset Pnom nominal output power Pin input p...

Страница 21: ...rt rma 13 Disposal INFORMATION INFORMATION All high voltage equipment and integrated components are largely made of recyclable materials Do not dispose the device with regular residual waste Please use the recycling and disposal facilities for electrical and electronic equipment available in your country 14 Manufacturer contact iseg Spezialelektronik GmbH Bautzner Landstr 23 01454 Radeberg OT Ross...

Отзывы: