
6700SR Refrigerated Sampler
55
If you select SAMPLING REPORT or RAINFALL (step
, shown in the margin), the sampler begins displaying the
report data. The sampler advances automatically through the re-
port items, displaying each item briefly. While the sampler advanc-
es automatically through the displays:
• Stop the automatic displays by pressing
Stop
once. Then, use
the arrow keys to move manually through the report.
• Return to the main menu by pressing
Stop
twice.
At the end of the report, the sampler leaves the last item displayed
until you press
• the arrow keys to move forward or backward manually through
the report.
•
Stop
to return to the main menu.
•
Enter
to start the automatic displays again.
If you select MODULE DATA or YSI DATA in step
, the sampler
displays the screen shown in step 4. Select the DAILY SUMMARY
option and the sampler displays the stored data one day at a time.
Selecting the CURRENT READINGS option causes the sampler to
display real-time readings. When there are multiple screens, they
will alternately be displayed. You can quickly advance through the
screens by pressing an arrow key or enter. Pressing
Stop
exits ei-
ther mode.
Configuring Reports
The Configure Report option allows you to specify which of the
Sampling Reports will be included in any output request. Each
sampler is shipped with the option ALL REPORTS selected. This
provides every available report and detailed partition data from
the module, rain, and YSI readings.
The SAMPLINK REPORT and FLOWLINK REPORT options al-
low you to tailor the output to the Isco software used to collect the
reports. The SAMPLINK REPORT option provides the Sampling
Reports, but disables the output of the detailed partition data. For
example, if you use an RTD and Isco SAMPLINK software to collect
the Sampling Reports, the SAMPLINK REPORT option will signif-
icantly reduce the data collection time and save RTD storage space.
The sampler withholds the partition data that cannot be read by
SAMPLINK.
FLOWLINK REPORT provides the Sampling Reports and the de-
tailed partition data. Selecting the FLOWLINK REPORT option
enables the output of the detailed partition data so FLOWLINK
can add the data to the site’s database file.
When you are familiar with the available Sampling Reports, you
may want to specify an output containing only the specific data you
require. The CUSTOM REPORT option will allow selection of each
printed report and of detailed data. Data collection time, printout
length, and storage space may be optimized using this option.
Viewing Data
1
RUN
PROGRAM
VIEW REPORT
OTHER FUCTIONS
• Select VIEW REPORT.
2
VIEW DATA
PRINT DATA
SYSTEM IDs
CONFIGURE REPORTS
• Select VIEW DATA.
3
VIEW:
SAMPLING REPORT
MODULE DATA
RAINFALL DATA
• Select a report or data type.
4
VIEW:
DAILY SUMMARY
CURRENT READINGS
• Select Daily Summary to view
the stored data, or Current
Readings to view real-time
data.
Configuring Data
1
RUN
PROGRAM
VIEW REPORT
OTHER FUCTIONS
• Select VIEW REPORT.
2
VIEW DATA
PRINT DATA
SYSTEM IDs
CONFIGURE REPORTS
• Select CONFIGURE
REPORTS
3
SAMPLINK REPORT
FLOWLINK REPORT
CUSTOM REPORT
ALL REPORTS
• Select the option that matches
your data collection software,
or tailor the output according
to the reports needed.
Содержание 6700SR
Страница 2: ......
Страница 4: ......
Страница 18: ...6700SR Refrigerated Sampler iv...
Страница 148: ...6700SR Refrigerated Sampler 130 Appendix B Material Safety Data Sheets...
Страница 149: ...6700SR Refrigerated Sampler 131...
Страница 150: ...6700SR Refrigerated Sampler 132...
Страница 151: ...6700SR Refrigerated Sampler 133...
Страница 152: ...6700SR Refrigerated Sampler 134...
Страница 153: ...6700SR Refrigerated Sampler 135...
Страница 154: ...6700SR Refrigerated Sampler 136...
Страница 155: ...6700SR Refrigerated Sampler 137...
Страница 156: ...6700SR Refrigerated Sampler 138...
Страница 157: ...6700SR Refrigerated Sampler 139...
Страница 158: ...6700SR Refrigerated Sampler 140...
Страница 159: ...6700SR Refrigerated Sampler 141...
Страница 160: ...6700SR Refrigerated Sampler 142...
Страница 161: ...6700SR Refrigerated Sampler 143...
Страница 162: ...6700SR Refrigerated Sampler 144...
Страница 163: ...6700SR Refrigerated Sampler 145...
Страница 164: ...6700SR Refrigerated Sampler 146...
Страница 165: ...6700SR Refrigerated Sampler 147...
Страница 166: ...6700SR Refrigerated Sampler 148...
Страница 167: ...6700SR Refrigerated Sampler 149...
Страница 168: ...6700SR Refrigerated Sampler 150...
Страница 174: ...6700SR Refrigerated Sampler 156 Appendix D Replacement Parts REFRIGERATOR ASSEMBLY FRONT BACK...
Страница 175: ...6700SR Refrigerated Sampler 157 REFRIGERATOR ASSEMBLY...
Страница 176: ...6700SR Refrigerated Sampler 158 MODEL 6700 CONTROLLER INSIDE...
Страница 177: ...6700SR Refrigerated Sampler 159 MODEL 6700 CONTROLLER INSIDE...
Страница 178: ...6700SR Refrigerated Sampler 160 MODEL 6700 CONTROLLER OUTSIDE...
Страница 179: ...6700SR Refrigerated Sampler 161 MODEL 6700 CONTROLLER OUTSIDE...
Страница 180: ...6700SR Refrigerated Sampler 162 MODEL 6700 PUMP GEAR CASE ASSEMBLY...
Страница 188: ...6700SR Refrigerated Sampler 170...
Страница 190: ......