STEP1: The first step is to cut out the area for the control
STEP2: Mount the resolver with the spring bracket, the proximity switch and the RBPC.
STEP3: Wire the RBPC as per the included wiring diagram
STEP4: Put the mode key-switch in PROG position
STEP5: Clear all the faults on screen (see section 2.6)
STEP 6: Once the control states “Press EXIT to Conf.” in the fourth line of the display, then proceed.
STEP 7: Now the resolver offset must be programmed. Refer to the
Resolver Settings
section of the RBPC User's
Manual for step-by-step instructions.
Page 4 of 15
RESOLVER
RESOLVER CHAIN LINK
PROXIMITY SWITCH AND
MOUNTING BRACKET
Resolver mounted with a chain and
sprocket from the existing cam shaft.
A resolver spring bracket must be
used to avoid damaging the resolver
due to improper axial load.
The proximity switch is mounted so that
it is directly actuated by the cam of the
press. The proximity has to be mounted
so that it is activated when the machine
is a the top dead centre.
Mount the resolver on the spring bracket
as shown in the drawing.
When the chain link is in place, the
bracket should be compressed half way
in. This will provide proper load
absorption and will allow an easy removal
of the chain if required.