iRZ ES75iT Скачать руководство пользователя страница 19

 

 

19 

 

4.  Emergencies 

To facilitate the use of the modem tracking and indication of emergencies is provided.  

4.1.  Emergency 1 (incorrect input power supply) 

Emergency 1 occurs when the input power supply deviates from the permissible value. The modem stops 

working and it shuts down the GSM module power. A permanent red LED signals that the emergency has 

occurred. The recovery is possible only when the input power supply is re-established.  

4.2.  Emergency 2 (incorrect module power supply) 

Emergency 2 occurs when the GSM module power supply deviates from the permissible value. The modem 

stops working and it shuts off the GSM module power. A red LED signals that the emergency has occurred 

(0.5s on / 0.5s off). The recovery is possible only if the module power supply is re-established within 10 

seconds after the emergency occurred. If within 10 seconds the module power supply remains incorrect (with a 

correct input power supply), the modem goes into the waiting mode meaning that the modem’s power supply is 

turned off, the emergency indication is preserved. The waiting mode can be terminated only after the power is 

completely disconnected.  

In case of repeated emergency, the modem should be serviced.  

4.3.  Emergency 3 (GSM module failed to start) 

Emergency 3 occurs if the GSM module does not turn on or is absent. A red LED signal (0.25s on / 0.25s 

off / 0.25s on / 1s off) turns on after a precise determination by the modem of the emergency situation (~15 

sec). The recovery is possible only after a successful launch of the GSM module. After 10 unsuccessful 

attempts to launch the module, the modem goes into the waiting mode meaning that the modem’s power 

supply is turned off, the emergency indication is preserved. The waiting mode can be terminated only after the 

power is completely disconnected.  

In case of repeated emergency after the modem is turned back on, the modem should be serviced. 

4.4.  Emergency 4 (COM-port not ready) 

Emergency 4 occurs if COM-port of the GSM module is not ready. A red LED signals that the emergency 

has occurred (0.25s on/ 0.25s off/ 0.25s on / 0.25s off / 0.25s on / 1s off). The recovery depends on the 

readiness of the COM-port of the GSM module. After 10 unsuccessful attempts (20 seconds) the modem goes 

into the wait mode meaning that the modem’s power supply is turned off and the emergency indication is 

preserved. 

In case of repeated emergency after the modem is turned back on, the modem should be serviced. 

Содержание ES75iT

Страница 1: ......

Страница 2: ... 2 TJ6 6P6C power connector 9 2 5 3 USB type B connector 10 2 6 Modem status display 11 3 Connecting and configuring 12 3 1 Connecting 12 3 2 Control rebooting shutdown 12 3 3 Types of watchdog timers 13 3 4 Menu mode 13 3 5 Programming mode 16 4 Emergencies 19 4 1 Emergency 1 incorrect input power supply 19 4 2 Emergency 2 incorrect module power supply 19 4 3 Emergency 3 GSM module failed to star...

Страница 3: ...lay green LED 11 Table 2 6 2 Emergency display red LED 11 Figures Fig 2 4 1 Front view 7 Fig 2 4 2 Back view 7 Fig 2 5 1 DB9 connector 8 Fig 2 5 3 Power connector 9 Fig 2 5 4 USB connector type B 10 Fig 3 1 Main view 16 Fig 3 2 Port opening 17 Fig 3 3 File uploading 17 Fig 3 4 File is uploaded 17 Fig 3 5 Flash memory writing 18 Fig 3 6 Exiting program mode 18 ...

Страница 4: ...inal off when on an airplane Take measures to avoid accidental turning on Turn the modem off in the vicinity of gas stations chemical plants and places where demolition work is conducted Interference for technical devices may occur At a close range the modem may produce interference for television sets and radio transmitters Maintenance requirements Protect the modem against external hazards high ...

Страница 5: ...of time The modem is controlled by standard AT commands and also possesses its own range of control commands The device is equipped with LEDs to monitor connection status and signal for emergency 2 2 Set The set of the GSM modem ES75iT includes ES75iT terminal Factory package 2 3 Features Key features Frequency ranges GSM 850 900 1800 1900MHz Output power 2W class 4 for EGSM850 900 1W class 1 for ...

Страница 6: ...temperatures from 30 С to 60 С Interfaces DB9 F connector for connecting the communication cable with RS232 interface USB type B connector for connecting the communication cable with USB 2 0 interface FME Jack male for connecting the GSM antenna TJ6 6P6C for RJ12 power connector for powering the modem ...

Страница 7: ...iew Fig 2 4 2 Back view The numbers on Fig 2 4 1 and Fig 2 4 2 stand for 1 USB B connector for connecting the communication cable with USB 2 0 interface 2 LED 3 SIM card tray 4 SIM card tray eject button 5 DB9 F connector for connecting the communication cable with RS232 interface 6 TJ6 6P6C power connector 7 FME Jack male for connecting the GSM antenna ...

Страница 8: ...ig 2 5 1 Fig 2 5 1 DB9 connector Table 2 5 1 Using DB9 connector pins Pins Signal Direction Purpose 1 DCD Modem PC Presence of the carrier 2 RXD Modem PC Data reception 3 TXD PC Modem Data transmission 4 DTR PC Modem Readiness for data reception 5 GND General Ground 6 DSR Modem PC Data readiness 7 RTS PC Modem Request to transmit 8 CTS Modem PC Readiness for data transmission 9 RI Modem PC Call si...

Страница 9: ... 5 2 TJ6 6P6C power connector The connector is used to power the device and reset the module Its appearance is displayed on Fig 2 5 2 Fig 2 5 2 Power connector Table 2 5 2 Using connector power pins Contact Signal Purpose 1 12V The positive pole of DC supply voltage Fused circuit and overvoltage protection when applied to the input voltage of over 30V and reverse polarity 2 Not used 3 Not used 4 N...

Страница 10: ...rol device using USB 2 0 interface Its appearance is displayed on Fig 2 5 3 Fig 2 5 3 USB connector type B Table 2 5 3 Using USB connector pins Contact Signal Purpose 1 V BUS 5V used as input to determine USB connection 2 D Data transmission 3 D Data transmission 4 GND Ground ...

Страница 11: ...tion has been established 500ms on 50ms off Data transmission under way 250ms on 10s off Modem is in the sleep mode the alarm mode 250ms on 250ms off Programming mode menu mode Permanently turned on Voice call CSD Configurations of display mode with AT SSYNC 2 and AT SSYNC 1 is differ only by power saving mode For more information see GSM module documentation Table 2 6 2 Emergency display red LED ...

Страница 12: ...e driver is installed a modem will be added to the hardware manager After the SIM card s PIN code is removed the device is automatically registered online which is indicated by the green indicator blinking rapidly Once the registration is completed the modem goes into the operation after which the green indicator begins to blink less rapidly see Table 2 6 1 3 2 Control rebooting shutdown Connectio...

Страница 13: ...waits a response at and then OK If no response is received the GSM module reboots The module s power in the meantime is shut down This function can be activated or switched off in the menu mode This function is switched off by default An unconditional reboot of the modem after a period of time set by user This function is switched off by default The period of time can be set between 1 and 255 hour...

Страница 14: ...modem has been turned on Bad_Power_Modem the number of times the modem power has deviated from the allowed Power_Module the number of times the power of the GSM module has been turned on Bad_Power_Module or the number of times the GSM module power has deviated from the allowed Start_Module the number of the successful launches of the GSM module Bad_Start_Module the number of situations when the GS...

Страница 15: ...case incorrect information is entered the modem will show ERROR and will offer the AT submenu once again In case correct information is entered or Q command is sent a transition into the main menu will take place Use P4 command to proceed to the SLEEP submenu Mode 0 off 1 on Q Quit Mode In this submenu a transition into the sleep mode is programmed allowed or prohibited If you need to prohibit a t...

Страница 16: ... menu takes place After entering the M command the main menu appears The exit from the menu mode occurs after the SIM tray is installed back again The modem goes into the working mode 3 5 Programming mode Program mprog is used to change or update software of the managing microcontroller of the modem Figure 3 1 shows an external view and main features 1 language 2 working with ports 3 working with ...

Страница 17: ... modem The modem will go into the programming mode The green LED will blink 250ms on 250ms off Open button not later than 10 sec once the modem was powered 5 Click the button not later than 10 sec once the modem was powered in Port frame The device model should appear For example see figure 3 2 MC52i 485 or BGS2 485 Fig 3 2 Port opening Then select the new firmware file to be downloaded 6 Click th...

Страница 18: ...5 Flash memory writing 8 Next click the button in bottom part of program window This will make the modem exit from programming mode and the port will be closed Fig 3 6 Exiting program mode 9 Close the program 10 Place the SIM holder into the modem The software update is completed The modem goes into the work mode ...

Страница 19: ...s completely disconnected In case of repeated emergency the modem should be serviced 4 3 Emergency 3 GSM module failed to start Emergency 3 occurs if the GSM module does not turn on or is absent A red LED signal 0 25s on 0 25s off 0 25s on 1s off turns on after a precise determination by the modem of the emergency situation 15 sec The recovery is possible only after a successful launch of the GSM ...

Страница 20: ...ftware are available using Company website www irz net Telephone 86 755 8832 9100 E mail support irz net Our support team is ready to assist you with any questions you might have when installing configuring or solving issues with our equipment ...

Отзывы: