DDA-4320 & ZDA-4320RH Instruction Book 

Revision 7

 

www.irtelectronics.com 

Page 13 of 16 

4320-DDA_ib_Rev7.doc 

SNMP with IRT Products: 

 
IRT Electronics currently employs SNMPv1 with its SNMP capable frames. The frame acts as an 

agent

 when fitted 

with a CDM-xxxx module. This module has its own designated slot next to the power supply so as to not affect the 
number of modules that the frame will take. Communication between the 

NMS

, the frame and its loaded modules 

are via this CDM-xxxx module. Note that the 

NMS

 software is third party and not supplied by IRT Electronics. 

 
Ethernet connection for SNMP operation is via an RJ45 connector on the rear of the frame, below the mains inlet. 
Ethernet rate runs at either 10 baseT or 100 baseT. 
 
Frame parameters, such as Name, Address and Location, are set via an RS232 interface, a D9 connector on the rear 
of the frame below the mains inlet. A software terminal emulator, such as Tera Term or HyperTerminal, is used for 
setting and reading the parameters of the frame. 
 
IRT modules that are SNMP compatible need a plug-in SMU-4000 module with a program relevant to the module 
that  it  is  plugged  into.  Depending  on  the  module,  besides  the  module  identification,  parameters  such  as  alarm 
states, inputs and controls etc. are communicated to the CDM-xxxx 

agent

 via a data bus on the rear of the frame. 

Thus the CDM-xxxx collects information on what is loaded within the frame, what positions they occupy, and their 
current status for communication to the 

NMS

 when the 

NMS

 sends a request for information.  

 
In the event of a major alarm from any of the SNMP compatible modules, or power supplies, a 

trap

 is automatically 

sent by the CDM-xxxx 

agent

 to the 

NMS

 without any prompting by the 

NMS

. This alerts the operator to any fault 

conditions that may exist that need immediate attention. 
 
 
 

FRU-4000

FRAME

110/240 V  50/60 Hz

0.7 A (max.)

FUSES

110/120 Vac

1A  S.B.

220/240 Vac

500 mA  S.B.

      AS3260 approval no.: CS6346N
Ass. no.: 804692     

48Vdc 

Alarm 

RS232 

Ethernet 

IRT SNMP Connections 

IRT modules fitted 

with SMU-4000 

PSU’s 

CDM-xxxx 

IRT SNMP Frame 

IRT SNMP Frame 

IRT modules fitted 

with SMU-4000 

PSU’s 

CDM-xxxx 

IP 

Network 

Ethernet Cable 

Ethernet Cable 

Ethernet Cable 

NMS 

IRT SNMP Setup 

Содержание DDA-4320

Страница 1: ...r ZDA 4320RH Handshake Changeover Assembly Designed and manufactured in Australia IRT can be found on the Internet at http www irtelectronics com I R T Electronics Pty Ltd A B N 35 000 832 575 26 Hoth...

Страница 2: ...912017 4 01 09 2010 AL Alarm conditions changed SNMP parameters changed Firmware versions DDA4320 F4aV1 S4V1 applicable to S N 0912030 DDA4320 F4V1 S4V1 applicable to S N 1009001 5 24 09 2010 AL DIP s...

Страница 3: ...DDA 4320 SNMP Functions 14 Maintenance Storage 16 Warranty Service 16 Equipment return 16 This instruction book applies to units with serial numbers 0912017 0912030 with firmware version DDA4320 F4aV...

Страница 4: ...n the front panel for use where modules are so linked A manual changeover request may be made either locally by using the front panel switch remotely via a connection on the rear assembly or via Simpl...

Страница 5: ...with ZDA 4320RH double width rear assembly Outputs 3 SK8 4 SK4 not fitted CHANGE ALLOW INHIBIT CHANGE REQUEST SET RECLOCKER RATE SW3 1 SW3 2 SW3 3 EQUALISER REDUCTION ENABLE OUTPUT AIS ENABLE SWITCHIN...

Страница 6: ...stand alone operation DATA LOSS LED red when no input is present or invalid input signal not applicable to AIS AIS LED red when Alarm Indication Signal AIS detected in STM 1 data CHANGE ALLOW Allow sw...

Страница 7: ...hangeover logic A changeover to the companion module will occur under any of the following conditions Loss of input signal or input signal does not match the set signal type AIS detection alarm provid...

Страница 8: ...e frame Agent CDM card 9 NOTE 5 For optical transmission the STM 1 signal presents an NRZ format without the CMI encoding used in electrical transmission In this instance it is not an actual optical i...

Страница 9: ...assis earth No attempt should be made to break this connection Installation in frame or chassis See details in separate manual for selected frame type Stand alone Operation Input Outputs For use with...

Страница 10: ...ing its relevant module PL1 corresponds to the B module and PL6 corresponds to the A module Pin 1 Tally a connection to ground indicates that the corresponding module is acting as the Main path 2 Exte...

Страница 11: ...round PL2 INPUT OUT 1 OUT 5 OUT 2 OUT 6 PL5 PL6 1 2 3 PL2 INPUT A OUT 5A OUT 6 OUT 5B OUT 2 PL3 PL2 PL5 PL4 OUT 1 INPUT B 1 2 3 4 5 PL1 1 2 3 4 5 PL6 NOTE Relay bypass between INPUT and OUT 6 on loss...

Страница 12: ...ent information and translates that information into a form compatible with SNMP The agent therefore acts as an interface between the NMS and the managed devices The NMS sends a request message and co...

Страница 13: ...frame IRT modules that are SNMP compatible need a plug in SMU 4000 module with a program relevant to the module that it is plugged into Depending on the module besides the module identification parame...

Страница 14: ...rred somewhere earlier in the system set this setting to enable 2 to correct the data stream irt4320ddaDataRate Set the input data rate for the reclocker 1 stm1 cmi Standard STM 1 electrical encoding...

Страница 15: ...tus that is AIS LOS or invalid input 1 disabled Trap not sent on change of alarm status 2 enabled Trap sent on change of alarm status irt4320ddaFirmwareVer Read the firmware version of the main FPGA i...

Страница 16: ...arranty on components shall be extended by IRT only to the extent obtainable from the component supplier Equipment return Before arranging service ensure that the fault is in the unit to be serviced a...

Отзывы: