SNMP with IRT Products 

 
IRT Electronics currently employs SNMPv1 with its 4000 series frame. The frame acts as an 

agent

 when fitted with 

a CDM-4000 module. This module has its own designated slot next to the power supply so as to not affect the 
number of modules that the frame will take. Communication between the 

NMS

, the frame and its loaded modules 

are via this CDM-4000 module. Note that the 

NMS

 software is third party and not supplied by IRT Electronics. 

 
Ethernet connection for SNMP operation is via an RJ45 connector on the rear of the frame, below the mains inlet. 
Ethernet rate runs at either 10 baseT or 100 baseT. 
 
Frame parameters, such as Name, Address and Location, are set via an RS232 interface, a D9 connector on the rear 
of the frame below the mains inlet. A software terminal emulator, such as Tera Term or HyperTerminal, is used for 
setting and reading the parameters of the frame. 
 
IRT modules that are SNMP compatible need a plug-in SMU-4000 module with a program relevant to the module 
that it is plugged into. Depending on the module, besides the module identification, parameters such as alarm states, 
inputs and controls etc. are communicated to the CDM-4000 

agent

 via a data bus on the rear of the frame. Thus the 

CDM-4000 collects information on what is loaded within the frame, what positions they occupy, and their current 
status for communication to the 

NMS

 when the 

NMS

 sends a request for information.  

 
In the event of a major alarm from any of the SNMP compatible modules, or power supplies, a 

trap

 is automatically 

sent by the CDM-4000 

agent

 to the 

NMS

 without any prompting by the 

NMS

. This alerts the operator to any fault 

conditions that may exist that need immediate attention. 
 
 

FRU-4000

FRAME

110/240 V  50/60 Hz

0.7 A (max.)

FUSES

110/120 Vac

1A  S.B.

220/240 Vac

500 mA  S.B.

      AS3260 approval no.: CS6346N
Ass. no.: 804692     

+

-

48Vdc

Alarm

RS232 

Ethernet 

IRT SNMP Connections 

IRT modules fitted 

with SMU-4000 

PSU’s

CDM-4000

IRT 4000 Series Frame

IRT 4000 Series Frame

IRT modules fitted 

with SMU-4000 

PSU’s

CDM-4000

IP 

Network 

Ethernet Cable 

Ethernet Cable 

Ethernet Cable 

NMS 

IRT 4000 Series SNMP Setup

Содержание DDA-4007

Страница 1: ...d and manufactured in Australia IRT can be found on the Internet at http www irtelectronics com I R T Electronics Pty Ltd A B N 35 000 832 575 26 Hotham Parade ARTARMON N S W 2064 AUSTRALIA National P...

Страница 2: ...turn 11 Drawing Index 12 This instruction manual applies to DDA 4007 later than S N 0809051 Operational Safety WARNING Operation of electronic equipment involves the use of voltages and currents that...

Страница 3: ...s to provide the number of outputs required This provides a more economic solution than using multiple reclocking DA s and minimises jitter increase due to unnecessary re clocking The rear assembly no...

Страница 4: ...ators Power LED green for 5 V Signal present LED green when signal present Alarm Signal loss Contact closure Link selectable NO NC Power requirement Voltage 28 Vac CT 14 0 14 or 16 Vdc Consumption 2 5...

Страница 5: ...hat the frame is connected to earth for safety reasons See frame manual for details Signal earth For safety reasons a connection is made between signal earth and chassis earth No attempt should be mad...

Страница 6: ...up with the three sets of multipin sockets on the main PCB module Align all pins and then gently press the SMU 4000 all the way down into place If the SMU 4000 is not already programmed with the corr...

Страница 7: ...l connector diagrams The following front panel and rear assembly drawings are not to scale and are intended to show relative positions of connectors indicators and controls only SK10 2 Alarm SK10 1 Gn...

Страница 8: ...that information into a form compatible with SNMP The agent therefore acts as an interface between the NMS and the managed devices The NMS sends a request message and control commands for the managed...

Страница 9: ...ed a plug in SMU 4000 module with a program relevant to the module that it is plugged into Depending on the module besides the module identification parameters such as alarm states inputs and controls...

Страница 10: ...tional plug in SMU 4000 SNMP module programmed with firmware to suit and installed in an IRT 4000 series frame with SNMP capability it is possible to remotely monitor the presence of an input and the...

Страница 11: ...extended by IRT only to the extent obtainable from the component supplier Equipment return Before arranging service ensure that the fault is in the unit to be serviced and not in associated equipment...

Страница 12: ...the diagrams are optional and are not included on standard production units They are shown to assist with interpretation of additional or optional functions which may be included or are necessary for...

Страница 13: ...100nF 5V 5V MON O P SK101 SIGNAL grn 2 1 R39 560R 2 1 LD2 HLMP 1503 5V ALARM CIRCUIT CONTACT CLOSURE OR BREAK TO GROUND ON ALARM AS SET BY LK1 3 2 1 Q1 BSS123 1 2 C37 4u7 R1 R9 220R L1 L9 15nH 3 8 RL...

Отзывы: