background image

Unpack & Inspect

1

4

Contents

5

Diverter

3

Diagrams of Ceres

The Radiator Company prides itself on selecting products from 

manufacturers who exercise tight quality control measures. We 

only select models with excellent standards of welding and 

brazing, as well as high quality finishes. All of our products are 

well packaged and should reach you in perfect condition. Just in 

case however, we offer a minimum 5-year no quibble guarantee 

for all radiators and towel rails.

Please carefully unpack and inspect this radiator and all fittings. 

The Radiator Company must be notified of any shortages or 

damage within 28 days of delivery. For further information please 

see terms and conditions on back page.

Pipe Centres

 Commission

Pipe centres left to right  

width + valves

Pipe centres from wall 

55mm to 80mm

Depth from wall 

 

80mm to 105mm

Please Note: In accordance with Part L1 2006 of the Building 

Regulations and BS7593:1992 code of practice for the treatment 

of hot water and central heating systems, we strongly recommend 

flushing the heating system post installation of new radiators and 

then adding the correct quantity and type of inhibitor for use with 

your radiator and system to prevent corrosion. Damage caused to 

systems not protected by a suitable inhibitor will not be covered 

by manufacturer’s guarantee. 

• 

4 wall brackets sleeves

• 

4 grub screws

• 

2 airvents

1.   Loosely attach the bracket sleeves to the fixed bracket studs.

2.   Position the radiator against the wall and mark the location 

of the top bracket sleeves; approx 45mm in from each corner and 

25mm down from the top (see diagram opposite).

3.   It is essential to accurately 

mark these positions as there is 

little tolerance for movement on the 

brackets. Check the positions are 

level and then using the appropriate 

drill bits, screws and plugs fit the top 

wall bracket sleeves.

4.   Re-position the radiator 

inserting the studs into the top 

bracket sleeves, check it is level and 

then mark the location of the bottom 

bracket sleeves approx 45mm in from 

each corner and 25mm up from the 

bottom (see diagram opposite).

5.   Then using the appropriate drill 

bits screws and plugs fit the bottom 

wall brackets sleeves to the wall and 

use a spirit level to check they are 

horizontally level.

6.   Insert the bracket studs into the  

bracket sleeves and secure using the 

grub screws provided on the side of 

the bracket sleeve. 

PLEASE NOTE:  

It is essential that all brackets are level to ensure a vertical 

alignment for connecting the pipework and that fixings are suitable 

for the wall material. 

2

The Ceres radiator has a diverter fitted  

on the left hand side (see digrams) to 

ensure the correct flow of water, this 

should always be at the 

return end 

on 

the bottom collector. 

Fix Brackets and Hang

4

45

25

45

25

25

45

25

45

25

55 to 80

80 to 105

Wall fixings are supplied but are 
not suitable for all wall types. 
Please use suitable fixings.

X

X

=diverter position

To locate the diverter, look through the end of the bottom collectors; 

one will be clear and one will have a blockage (the diverter).

flow

return

continued...