Unpack & Inspect
1
4
Contents
5
Diverter
3
Diagrams of Ceres
The Radiator Company prides itself on selecting products from
manufacturers who exercise tight quality control measures. We
only select models with excellent standards of welding and
brazing, as well as high quality finishes. All of our products are
well packaged and should reach you in perfect condition. Just in
case however, we offer a minimum 5-year no quibble guarantee
for all radiators and towel rails.
Please carefully unpack and inspect this radiator and all fittings.
The Radiator Company must be notified of any shortages or
damage within 28 days of delivery. For further information please
see terms and conditions on back page.
Pipe Centres
Commission
Pipe centres left to right
width + valves
Pipe centres from wall
55mm to 80mm
Depth from wall
80mm to 105mm
Please Note: In accordance with Part L1 2006 of the Building
Regulations and BS7593:1992 code of practice for the treatment
of hot water and central heating systems, we strongly recommend
flushing the heating system post installation of new radiators and
then adding the correct quantity and type of inhibitor for use with
your radiator and system to prevent corrosion. Damage caused to
systems not protected by a suitable inhibitor will not be covered
by manufacturer’s guarantee.
•
4 wall brackets sleeves
•
4 grub screws
•
2 airvents
1. Loosely attach the bracket sleeves to the fixed bracket studs.
2. Position the radiator against the wall and mark the location
of the top bracket sleeves; approx 45mm in from each corner and
25mm down from the top (see diagram opposite).
3. It is essential to accurately
mark these positions as there is
little tolerance for movement on the
brackets. Check the positions are
level and then using the appropriate
drill bits, screws and plugs fit the top
wall bracket sleeves.
4. Re-position the radiator
inserting the studs into the top
bracket sleeves, check it is level and
then mark the location of the bottom
bracket sleeves approx 45mm in from
each corner and 25mm up from the
bottom (see diagram opposite).
5. Then using the appropriate drill
bits screws and plugs fit the bottom
wall brackets sleeves to the wall and
use a spirit level to check they are
horizontally level.
6. Insert the bracket studs into the
bracket sleeves and secure using the
grub screws provided on the side of
the bracket sleeve.
PLEASE NOTE:
It is essential that all brackets are level to ensure a vertical
alignment for connecting the pipework and that fixings are suitable
for the wall material.
2
The Ceres radiator has a diverter fitted
on the left hand side (see digrams) to
ensure the correct flow of water, this
should always be at the
return end
on
the bottom collector.
Fix Brackets and Hang
4
45
25
45
25
25
45
25
45
25
55 to 80
80 to 105
Wall fixings are supplied but are
not suitable for all wall types.
Please use suitable fixings.
X
X
=diverter position
To locate the diverter, look through the end of the bottom collectors;
one will be clear and one will have a blockage (the diverter).
flow
return
continued...