Detailed Installation Instructions

There are two main components of the Wireless RainSensor: the Receiver and the
Sensor/Transmitter. The Receiver is installed adjacent to or within the cabinet of the
irrigation system controller. The Sensor/Transmitter is installed outdoors where it is
exposed to unobstructed rainfall.

Mounting the Receiver

1.

Always mount the Receiver FIRST, adjacent to the controller with either the 
provided stainless steel screws or double-sided foam tape. The connection wire
cable is 20" (50cm) long, so before attaching the Receiver, make sure the wires
will easily reach the controller’s connection terminals.

Wiring the Receiver

There are two parts involved in wiring the Receiver:

Part 1:

Attach the Receiver control wires (similar to hard-wired sensors).

Part 2: 

Attach the low-voltage power wires to supply 24 VAC to the Receiver.

Part 1 - Control Wire Connection

The Receiver control wires are used to interrupt the common wire of the valves or they
can be connected directly to the sensor input terminals of the controller (if provided).

1.

Disconnect power to the controller.

2.

Follow applicable wiring procedure 

A

or

or

C

.

Note:

The following diagrams are representations only and do not depict actual 

controller layouts. Refer to the installation instructions provided with your controller for
specific wire connection information.

A. Controllers with sensor inputs (with or without pump/master valve):

Refer to 

Figure 6

. Find the controller sensor terminals (generally marked “Sensor”,

“SEN” or “S”) and directly connect the White and Brown* wires to these terminals
in any order. There may be a jumper wire or tab connecting the terminals that
must be removed and/or a sensor bypass/control switch that must be activated. 

4

Figure 6

Red

Brown

*

Common From Valves

To Valves

Irrigation System Controller

White

Red

*

Note: 

Use Yellow wire in place of Brown

if a Normally Open sensor is required.

Содержание RFS1000

Страница 1: ...tallation methods must comply with all applicable national and local building codes If you are unsure about proper wiring practices have a qualified contractor perform the installation for you The Rec...

Страница 2: ...ss and hold for 5 7 seconds to turn off the receiver 6 Power Indicator Steady light 24 VAC power is connected Blinking light Sensor Transmitter battery power low or other communication problem No ligh...

Страница 3: ...ighten the Receiver antenna wire upward and the Sensor Transmitter antenna wire downward 6 While holding the Sensor Transmitter at close range to the Receiver press and hold the spindle to test the wi...

Страница 4: ...er Part 1 Control Wire Connection The Receiver control wires are used to interrupt the common wire of the valves or they can be connected directly to the sensor input terminals of the controller if pr...

Страница 5: ...sensor inputs Refer to Figure 8 Disconnect all common control wires from the common terminal s of the controller generally marked C Com or VC Join these wires to the White wire using a wire connector...

Страница 6: ...Refer to Figure 9 On controllers that do not have 24 VAC terminals connect the two Red power wires to the transformer s secondary 24 VAC power wires where they attach to the controller s circuit board...

Страница 7: ...ignal Prior to testing the Sensor Transmitter in its final location clear the Signal Indicator first so the test will represent the signal as received during the final check To clear the Signal Indica...

Страница 8: ...he controlled area out of direct sunlight and avoid ing direct southern exposure A northeast to northwest shaded exposure works well Important Avoid installation of the unit near a large heat storing...

Страница 9: ...ld the Smart Bypass button until the Sensor Status indicator begins blinking rapidly 5 7 seconds Release the Smart Bypass button and confirm the Power indicator goes out and flashes periodically Simpl...

Страница 10: ...ransmitter and Receiver Although in most cases even if two identical units are installed unwanted activations would only occur if the two sensors are set for different rainfall amounts However the cod...

Страница 11: ...duce the effective transmitted signal enough to pose problems under normal installation conditions However there are some installations with very thick dense walls or that involve large amounts of rad...

Страница 12: ...roperly that is in strict accordance with the manufacturer s instructions may cause interference to radio and television reception It has been type tested and found to comply with the limits for a FCC...

Отзывы: