34
6. To complete the process, press the
button again to display the
prompt “
End
”.
7. Return the
Dial
to the
Current Time
position.
8. Return the
Function
switch to the
Run
position.
Restore Factory Default Settings
The Rain Dial-R factory default settings for automatic program operation
are as follows:
Current Time: 12:00 AM.
Current Day: Sunday.
Current Date: January 1, 2008.
Program
A
:
Weekday watering schedule with all days active.
One start time at 7:00 AM.
10-minute run time on all valve stations.
Program
B
and
C
: No watering days, station run times or start times.
Skip Days and Odd/Even day schedule: OFF - all Programs.
Excluded days in Skip Days or Odd/Even schedule: None.
MV/Pump operation: ON - all stations.
Well Recovery period: 00 (OFF) - all Programs.
MV/Pump operation during Well Recovery: OFF - all Programs.
Water Budget: 100% - all Programs and months.
Rain Delay: 0 days.
Stack/Overlap: Overlap - 3 Programs or 3 manual stations.
To restore factory default settings:
1. Turn the dial to
Start Time
number 3.
2. Repeatedly press the
Manual
button.*
3. After the first 7 depressions, the firmware version appears in
the display.
4. On the 14th depression, “CLr” appears.
5. On the 15th depression, “ALL” appears.
6. On the 16th depression, “OFF” begins flashing indicating erasure of
all user-entered information.
7. Turn the dial back to CURRENT TIME. “12:00AM” appears in the