Utility Menu Options / Water Adjust Feature
15
14
Setup / Utility Menu Options
Default
(
DEFAULT
_
ENTER
): The Default utility feature enables
all user-defined setup parameters to be either erased and reset to
the factory default settings, or a
complete system reset includ-
ing Location, History, and Sensor Pairing.*
• Press the
YES
key to reset to the
Factory Default
settings.
See Default settings listed on page 12
.
• Press the
NO
key to return to the previous screen.
• Press the
ERASE
key to display the
Erase All
prompt screen.
• Press the
NO
key to return to the
Utility Menu
screen.
• Press the
FACTORY
key to return the
Factory Reset
screen.
•
*
Press the
YES
key to initiate the
complete system reset
.
Complete the procedure as indicated on the prompt screens.
Water Adjust Feature
The Water Adjust feature enables watering time to be fine-tuned
by applying small adjustments universally to all weather-regulated
stations.
From the
Home
screen, press the
or
key to access the
Water Adjust
screen and to adjust scale. Press the
SAVE
key
to enter the change and return to the
Home
screen.
Note:
If a particular watering zone appears over-or under-watered,
adjust the station run time in the controller watering program.
It is considered best practice to make adjustments in small increments;
allowing several days between changes to observe the results.
Freeze Temperature (threshold): The
freeze sensor activation
threshold can be adjusted from 39° F (4° C), (default) down to 35° F
(2° C), or increased to 45° F (7° C), in 2° increments.
Important:
Freeze sensor operation should be used only when the
watered area can be visually monitored. While the Freeze Sensor is
designed to cancel watering when air temperature is near freezing,
automatic watering can occur in certain circumstances. For example,
the air temperature may rise slightly above the sensor threshold, while
the temperature of the adjacent walkways remains below freezing.
Watering in this condition can result in unsafe walkway conditions. The Freeze Sensor feature is not intended to
replace any winterization procedures normally used to prevent freeze-related irrigation system damage.
Dry-out Days:
This setting determines
the minimum length of time that must elapse after the release of
a rain/freeze hold, and automatic watering can resume. By default, the dry-out period is 1/2 day (12 hours),
and is adjustable from 0 to 3 days in 1/2-day increments.
Utility Menu Options
The following
Utility
features are accessed through the
Utility
Menu
screen (
MENU
_
UTILITY
_
ENTER
).
Display Contrast
(
CONTRAST
_
ENTER
): The LCD screen contrast
is factory set at the midpoint adjustment range. Contrast intensity
can be adjusted incrementally to the preferred level.
Units:
(
UNITS
_
ENTER
): By default, all units of measure are dis-
played in English standard format, and time in 12-hour (a.m./p.m.)
format. Metric units of measure, and/or 24-hour (military time)
formats can be selected as preferred.
ET Setup
Freeze Temperature 39F
Dry Out (days) 0.0
SAVE
3 of 3
BACK
CANCEL
NEXT
Utility Menu
Contrast
Units
History
Loader
About
Default
EXIT
ENTER