background image

 

Utility Menu Options / Water Adjust Feature 

15

 

14

 

Setup / Utility Menu Options

Default 

(

DEFAULT 

_

 ENTER

): The Default utility feature enables 

all user-defined setup parameters to be either erased and reset to 

the factory default settings, or a 

complete system reset includ-

ing Location, History, and Sensor Pairing.* 

  • Press the 

YES

 key to reset to the 

Factory Default

 settings.  

See Default settings listed on page 12

.

  • Press the 

NO

 key to return to the previous screen.

  • Press the

 ERASE

 key to display the 

Erase All 

prompt screen.

  •  Press the 

NO

 key to return to the 

Utility Menu 

screen.

 

• Press the 

FACTORY 

key to return the 

Factory Reset

 screen. 

 

• 

*

Press the 

YES

 key to initiate the 

complete system reset

Complete the procedure as indicated on the prompt screens. 

  Water Adjust Feature

The Water Adjust feature enables watering time to be fine-tuned 

by applying small adjustments universally to all weather-regulated 

stations. 
From the 

Home

 screen, press the

or

key to access the  

Water Adjust 

screen and to adjust scale. Press the 

SAVE

 key  

to enter the change and return to the 

Home

 screen. 

Note:

 If a particular watering zone appears over-or under-watered, 

adjust the station run time in the controller watering program.  

It is considered best practice to make adjustments in small increments; 

allowing several days between changes to observe the results.

Freeze Temperature (threshold): The 

freeze sensor activation 

threshold can be adjusted from 39° F (4° C), (default) down to 35° F 

(2° C), or increased to 45° F (7° C), in 2° increments.

Important:

 Freeze sensor operation should be used only when the 

watered area can be visually monitored. While the Freeze Sensor is  

designed to cancel watering when air temperature is near freezing,  

automatic watering can occur in certain circumstances. For example,  

the air temperature may rise slightly above the sensor threshold, while 

the temperature of the adjacent walkways remains below freezing.  

Watering in this condition can result in unsafe walkway conditions. The Freeze Sensor feature is not intended to  

replace any winterization procedures normally used to prevent freeze-related irrigation system damage.

Dry-out Days: 

This setting determines

 

the minimum length of time that must elapse after the release of 

a rain/freeze hold, and automatic watering can resume. By default, the dry-out period is 1/2 day (12 hours), 

and is adjustable from 0 to 3 days in 1/2-day increments.

  Utility Menu Options

The following 

Utility

 features are accessed through the 

Utility 

Menu

 screen (

MENU 

_

 

UTILITY 

_

 

ENTER

). 

Display Contrast 

(

CONTRAST 

_

 ENTER

): The LCD screen contrast 

is factory set at the midpoint adjustment range. Contrast intensity 

can be adjusted incrementally to the preferred level.

Units: 

(

UNITS 

_

 ENTER

): By default, all units of measure are dis-

played in English standard format, and time in 12-hour (a.m./p.m.) 

format. Metric units of measure, and/or 24-hour (military time) 

formats can be selected as preferred. 

ET Setup

Freeze Temperature         39F
Dry Out (days)                  0.0

SAVE

3 of 3

BACK

CANCEL

NEXT

Utility Menu

Contrast
Units
History

Loader
About

Default

EXIT

ENTER

Содержание Climate Logic

Страница 1: ...matic watering cycle The Climate Logic system is designed for easy installation setup and use To take full advantage of the features and capabilities provided by the Climate Logic system take a moment...

Страница 2: ...e and controller to the current time and date See page 7 Step 4 Insert the Receiver Module Setup Card as shown See page 8 Step 5 Establish your location by entering the five digit ZIP code or Lat Lon...

Страница 3: ...ED will turn on momentarily when the signal is received Press the BYPASS key to cancel the Dry out mode delay period and resume normal operation See page 9 Note If the LED does not turn on refer to th...

Страница 4: ...R ADP KwikDial Adaptor Cable Adapts RJ25 connector to KwikDial controller s 5 pin receptacle 6 Cover Provides weather resistance and display protection in closed position 7 Connector Cable Plugs into...

Страница 5: ...fall 3 Solar Collector Collects and measures solar radiation Requires full exposure to sunlight 4 Battery Compartment Factory installed 9V Alkaline battery can sustain normal Weather Sensor operations...

Страница 6: ...ble connector into the controller s remote control jack Note Use the provided CMR ADP cable adapter assembly for KwikDial and MC E Blue controller applications 3 Secure the Receiver Module to the wall...

Страница 7: ...selected underscored value Press the NEXT key to select the next value Continue setting the current day year and time Note To change the clock time display format press the 12 24 key To return to the...

Страница 8: ...ess the NEXT key to select the next value in sequence When the location information is displayed correctly press the SAVE key Note The Receiver Module will begin transferring specific data from Setup...

Страница 9: ...ion from the factory The following procedure will only be required if Please Add Sensor is displayed on the Home screen 1 Pair the Weather Sensor transmitter with the Receiver Module to establish wire...

Страница 10: ...s well as extending the dry out period before scheduled watering can resume In areas where heavy fog mist or high humidity is common the 1 8 3 mm setting is not recom mended due to the increased sensi...

Страница 11: ...s on the Home screen to verify good signal strength Three bars is optimal Press the BYPASS key to cancel the Dry out delay mode to resume normal operation 4 Install the Weather Sensor using either of...

Страница 12: ...ctory default setting and the setup parameter for each Setup Menu Features Default Setup Parameter Auto Program Adjust Program A Program A A B or A B C Water Restriction Start Time None Any hour Water...

Страница 13: ...o the Receiver Module at regular intervals throughout the day At the default time of 8 00 p m the watering adjustment factor for the next 24 hours is calculated and updated on the Home screen The Sche...

Страница 14: ...not intended to replace any winterization procedures normally used to prevent freeze related irrigation system damage Dry out Days This setting determines the minimum length of time that must elapse...

Страница 15: ...to initiate the complete system reset Complete the procedure as indicated on the prompt screens Water Adjust Feature The Water Adjust feature enables watering time to be fine tuned by applying small...

Страница 16: ...day increments To adjust the Dry out time period refer to the Dry out Days setup procedure on page 14 Note To resume watering operation immediately after the reset press the BYPASS key to skip the Dry...

Страница 17: ...ames of approximately 2 months 6 months 1 year and 2 years Watering history data can also be reviewed in a contextual format accessible through the History option of the Utility Menu MENU _ UTILITY _...

Страница 18: ...To remove and replace the currently paired Weather Sensor press the REMOVE key to display the Remove Sensor screen Important A new Weather Sensor must be activated before it can be paired with the Rec...

Страница 19: ...to update the controller information Press the DECT Detect key to access the current controller time and date setting Remote PIN Setup The irrigation controller can be accessed through the Receiver Mo...

Страница 20: ...he upper housing by twisting it clockwise while holding the base stationary Disconnect the battery wire clip Remove the used battery and insert a fresh 9V Alkaline battery between the foam pad and hou...

Страница 21: ...ing option w vertical adjustment and stainless steel hardware Visible RF Transmission LED UL FCC and IC Approval FCC ID OF7WS9 IC 3575A WS9 Receiver Module Compatible with Remote ready Irritrol and To...