70
F
R
A
N
C
A
I
S
E
N
G
L
I
S
H
E
S
P
A
N
O
L
Initial programming
ANALOGICAL PRESSURE SENSOR
On this machine, there are three possible choices. To get from one choice to another, press the
"OTHER CHOICE" key :
ANALOGICAL NO:
To be chosen when the analogic sensor is not used.
ANALOGICAL YES :
With this choice, the analogic sensor is used to calculate more accurately the
water output of the machine ( from the pressure measured by the sensor and the
diameter of the nozzle, which has been programmed by the user.)
ANALOGICAL YES ++ :
With this choice, the analogic sensor is used :
- to calculate the water outputs of the machine
- to modify the advancing speed of the machine in case of pressure changes (the sensor
measures the pressure every minute).
CONNECTION OF THE ANALOGICAL PRESSURE SENSOR
GSM
Connector
Main green 24 terminal connector
4 terminal green connector
-
1.
Screw the blue wire.
-
2.
Screw the black wire.
-
3.
Screw the brown wire.
-
4.
not fitted
IF ORANGE CABLE:
-
1
Screw the green wire.
-
2
Screw the brown wire.
-
3
Screw the white wire.
-
4
not fitted.
1 2 3 4