background image

9

For best performance and to insure that the in-
stallation is free of ground loops that can create
obnoxious noise and hum problems, a technical
ground for the audio equipment should be
installed. In such a grounding system, the audio
electronic equipment is grounded at one point only
and with reference to the ac power connection to
the building (service entry). Depending upon the
size of the facility and the distance between the
equipment rack(s) and the service entry, a rela-
tively large ground conductor may be required to
establish a solid ground.

Do not rely on the building conduit/raceway

to provide a proper ground

Variance of ground potential between the

audio equipment and the service entry

should be <.25 Ohms.

Prior to commencing an installation, the design
of a well thought-out grounding plan can elimi-
nate most problems with interfering RFI (radio fre-
quency interference) and EMI (electromagnetic
interference). A properly conceived and imple-
mented grounding plan can save untold grief and
expense in trying to correct problems ‘after-the-
fact’.

Inter

Inter

Inter

Inter

Internal Equipment R

nal Equipment R

nal Equipment R

nal Equipment R

nal Equipment Rac

ac

ac

ac

ack

kk

kk

W

W

W

W

Wiring

iring

iring

iring

iring

For best performance and minimum interference,
internal rack wiring should be spaced with a
minimum of 4 inches (10 cm) between conduc-
tors having varying signal levels. That is, ac
wiring, input audio wiring, intermediate level
audio and output audio wiring should be
separated by a minimum of 4 inches from each
other. Varying signal levels and/or ac wiring should
never be bundled or tie-wrapped in a common
riser.

Connections

Connections

Connections

Connections

Connections

Audio Input Connections

Audio Input Connections

Audio Input Connections

Audio Input Connections

Audio Input Connections

All input connections are made on the rear panel
of the PA-4020B Power Amplifier. Each channel
is equipped with a 3-pin, screw-clamp, barrier-
strip type connector and a 3-pin, XLR-type con-
nector. Choose which type of connector you plan
to use and connect accordingly. Connections may
be made to either the terminal strip or to the XLR-
type connector; but not to both.
Both types of connectors have their respective
pins marked 1,2 and 3. Connections should be
made using the AES standard as follows:

Pin 1 – ground (shield)
Pin 2 – high (+) audio signal
Pin 3 – low (-) audio signal

Use two conductor, shielded cable for all audio
input lines.
Shields should be connected to ground at their
source end and not at the power amplifier.
Cable between the source and the power ampli-
fier should not exceed 18 inches (.5 meters).
Do not locate audio input cables closer than 4
inches (10 cm) from output, intermediate, or ac
wiring. See Grounding in the preceding Mounting
Section.

Determine whether the power amplifier will be
used in dual-channel mode or in the bridged
mode. In the dual-channel mode, connections are
made to both channel 1 and channel 2. If the unit
is to be used in bridged mode, connection is made
to channel 1 only. Make sure the bridge/stereo
selector switch is in the proper position for the
service intended.

See figure 2 for connection information:

A

A

A

A

Audio Output Connections

udio Output Connections

udio Output Connections

udio Output Connections

udio Output Connections

All output connections are made on the rear panel
of the PA-4020B Power Amplifier. Each channel
is equipped with a 2-conductor Neutrik

 

Speakon

connector and a pair of 4-way binding posts.
Choose which type of connector you plan to use
and connect accordingly. Connections should be
made to either the Neutrik connector or to the 4-
way binding posts; but not to both.

Содержание PA-4020B

Страница 1: ... net INST INST INST INST INSTALLA ALLA ALLA ALLA ALLATION TION TION TION TION OPERA OPERA OPERA OPERA OPERATIONS MANU TIONS MANU TIONS MANU TIONS MANU TIONS MANUAL AL AL AL AL P P P P PA SERIES PO A SERIES PO A SERIES PO A SERIES PO A SERIES POWER WER WER WER WER AMPLIFIERS AMPLIFIERS AMPLIFIERS AMPLIFIERS AMPLIFIERS P P P P PA 4020B A 4020B A 4020B A 4020B A 4020B ...

Страница 2: ...f le of Contents Contents Contents Contents Contents List of Tables and Figures ii Important Notices 4 FCC Compliance 5 Product Description 6 Specifications 7 UnPacking 8 Mechanical Mounting 8 Connections 9 Trouble Shooting 13 Warranty Provisions 13 i ...

Страница 3: ...output Connections 12 Figure 5 Bridged mode 70 7 volt output Connections 12 Table 1 Output Power versus Impedance 7 Table 2 Input Signal Characteristics Thermal Considerations 8 List of List of List of List of List of T T T T Ta a a a ab b b b bles and Figur les and Figur les and Figur les and Figur les and Figures es es es es ii ...

Страница 4: ... e e e e The PA 4020B is enclosed in a chassis which is devoid of ventilation holes Consequently it is by and large impervious to happenstance s where liquid or other corrosive elements can be intro duced into the interior of the chassis However the external connections on the rear panel of the amplifier could be adversely effected by exposure to water or other liquids Hence as a general precautio...

Страница 5: ...mined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient the receiving antenna Relocate the amplifier with respect to the receiver Move the amplifier away from the receiver Plug the amplifier into a different electrical outlet so that the amplifier and the receiver are on different electrical branch circui...

Страница 6: ...most easily specified and installed amplifiers available This iis reflected in its overall design and feature set The amplifier is able to operate on 120 or 240 volt ac power at 50 to 60Hz With convection cooling when idling the unit draws very little power thus producing remark ably little heat Inasmuch as it utilizes signal de pendent switching power supplies the highly effi cient PA 4020B has o...

Страница 7: ...icators Input channel connector 2 removable screw clamp connectors 2 XLR type 3 pin connec tor Output channel connectors each channel two 4 way binding posts each 2 Speakon connectors 1 Ground lift switch 1 Bridge mode switch 1 Ac line fuse 1 3 pole grounded male IEC connector Maximum audio power output see table Ac Power requirements 120 240V 10 50 60Hz draws 20 watts on idle 300 watts at 200 wat...

Страница 8: ...ment Examine the dipswitch carefully for possible ship ping damage Verify that the Bridge Stereo switch is in the proper position for the intended service Mounting Mounting Mounting Mounting Mounting The PA 4020B is intended for mounting in a stan dard 19 equipment cabinet and will occupy 1 RU 1 75 of rack space The unit is attached to the equipment rack by using four mounting screws inserted thro...

Страница 9: ...s Audio Input Connections Audio Input Connections Audio Input Connections Audio Input Connections All input connections are made on the rear panel of the PA 4020B Power Amplifier Each channel is equipped with a 3 pin screw clamp barrier strip type connector and a 3 pin XLR type con nector Choose which type of connector you plan to use and connect accordingly Connections may be made to either the t...

Страница 10: ...ector Input Connector Figure 2 Rear Panel Input Connections 1 2 3 N C Dual Channel mode both Channel Inputs 1 2 3 N C 1 2 3 N C Bridged mode Connection to Channel 1 Only 240V 3 A 120V 6A Input Connections Input Connections Input Connections Input Connections Input Connections ...

Страница 11: ...the PA 4020B will drive two output transformers to produce 350 watts at 70 7 volts When used in a constant voltage mode the sound system should have a high pass filter low frequency cut to prevent saturation of the constant voltage transformers A second order 12dB octave Butterworth filter at 40Hz or higher frequency is recommended A first order 6dB octave filter may be used if it is placed at 80H...

Страница 12: ... 100 watts per Channel Output Output Connections Output Connections Output Connections Output Connections Output Connections DH 100 DH 100 NC DH 100 NC NC 1 2 1 2 2 3 4 3 4 70 7 volts 200 watts Fig 5 Bridged mode Constant Voltage 200 watts Total Output ...

Страница 13: ...ries used therewith not of IRP manufacture IRP s obligation under this warranty as to any products or parts approved by IRP for remedy or exchange is limited at its option to replacing such products or parts in kind without charge to the original purchaser or to crediting the original purchaser with the purchase price of the returned defective products This warranty is in lieu of all other warrant...