background image

24

25

Setting up the Daily Rainfall Alert

1. In Rain Mode, press 

ALARM

 to display rainfall alert.

2. Press and hold 

ALARM

 until rainfall alert and “ALARM HI” starts flashing in the display.

3. Set Value for Rainfall Alert:

  Press 

UP

 or 

DOWN

 to adjust value. Press and hold either button for fast advance.

  Press 

ALARM

 to confirm your selection.

4. Upon completion the display will be returned to the rainfall alert display.

Disabling when Daily Rainfall Alert is Activated

To Disable Rainfall Alert:

Press 

ALARM

 to disable the alert.

Wind Mode

The wind direction is shown by an animated compass display. Its angle can be displayed 

as compass points (i.e. NW) or in bearings from the north (i.e. 22.5º).

The upper left of the wind display can be set to indicate the temperature at the 

anemometer or the temperature adjusted with a wind chill factor.

The lower left of the wind display indicates the average wind speed for the last 10 minutes, 

as well as gust, wind speed alert and gust alert information. It can also show records of the 

maximum values of wind speed and gust attained for the current day.

The wind speed and gust alert functions can be programmed to sound if the wind speed or 

gust exceeds a pre-configured limit. The wind speed may be displayed in km/h, mph, m/s 

or knots.

Note: The wind speed alert has a 5 mph hysteresis and the wind gust speed alert has a 

7 mph hysteresis. The hysteresis is to prevent the alerts from sounding constantly due to 

small fluctuations near the alert value. This means that after the wind speed reaches the 

alert value, it will have to fall below the alert value plus the hysteresis to deactivate the 

alert.

Accessing Wind Mode

From the main console unit: Press 

UP

 or 

DOWN

 until the WIND icon         on the display 

starts flashing.

From the remote control: Press         .

Configuring Wind Display

In Wind Mode, each press of 

SET

 rotates display between:

- Temperature with wind chill, wind direction in bearings 

- Temperature with wind chill, wind direction in compass points

- Temperature at anemometer, wind direction in compass points

- Temperature at anemometer, wind direction in bearings

Setting Units for Wind Speed Display (km/h , mph, m/s or knots)

In Wind Mode, press and hold 

SET

 to convert wind speed units between km/h, mph, m/s or 

knots.

Содержание PRO-EC

Страница 1: ...1 USER MANUAL PRO X USB ...

Страница 2: ...tion 14 Buttons and Controls 14 Navigating between Different Modes 17 Customizing your Weather Station 20 LED Backlight Options 21 Linking the Weather Station to a Computer 21 Using the Different Weather Modes 22 Pressure and Weather Forecast Mode 22 UV Mode 27 Clock and Alarm Mode 28 Sunrise Sunset Mode 34 Temperature and Humidity Mode 36 Rain Mode 38 Wind Mode 40 Maintenance 44 Troubleshooting 4...

Страница 3: ...er records can be displayed and saved onto the computer Remote Weather Sensors The remote weather sensors include a thermo hygrometer UV sensor anemometer wind sensor and rain sensor All data collected by the sensors is transmitted to the main console unit by wireless RF The weather station supports a maximum of 5 thermo hygrometers allowing 5 channels of temperature humidity display Features Weat...

Страница 4: ...ve humidity Comfort level indicator Analyzes current environmental conditions Comfort Wet and Dry Rainfall measurement Records rainfall amount for the last hour last 24 hours last day last week and last month inch or mm Daily rainfall alert if rainfall for the current day exceed pre specified amount Wind Temperature at place of anemometer Temperature adjusted to wind chill factor ºC or ºF Wind dir...

Страница 5: ... Unit Remote Control Hardware Komponenten Fittings UV Sensor Sensor Unit U Shaped Sensor holder Circular Base Stake Base Wall Mounting Base oder Thermo Hygro Sensor Rain Sensor Funnel shaped Lid with Battery Hatch Sensor Base Bucket See saw Mechanism Protective Screen 4 screws for securing unit to ground optional AC DC 7 5V output adaptor ...

Страница 6: ...ance The remote sensors should be cleaned on a weekly basis since dirt and debris will affect sensor accuracy Setting up the UV Sensor 1 Unscrew the lid on top of the UV sensor 2 Insert two 2 x UM 3 or AA size 1 5V batteries and screw the lid back onto the sensor 3 There are three different fittings available for mounting the UV sensor Ground Stand Attach the circular ground stand onto the U shape...

Страница 7: ...an anti clockwise direction 2 Lift the top off the base and insert two 2 x UM 3 or AA size 1 5V batteries into the battery holder 3 Replace the lid and secure into place by turning the knobs clockwise 4 Place the rain sensor in a location such that precipitation can fall directly into the sensor ideally 2 3 ft above the ground It may be secured into place by using the four screws provided 5 The se...

Страница 8: ...t wind can travel freely around the anemometer and is not distorted by nearby buildings trees or other structures For better results place the anemometer at least 3m above local structures and obstacles The ground creates a frictional effect to wind flow and will attenuate readings Aim for maximum exposure of the anemometer to the commonest wind directions in your area The official mounting locati...

Страница 9: ...he following areas Direct sunlight and surfaces which radiate and emit heat Near heating and ventilation devices such as heating ducts or air conditioners Areas with interference from wireless devices such as cordless phones radio headsets baby listening devices and electronic appliances Starting up the Main Console Unit Once the console unit is properly powered the display will start showing some...

Страница 10: ...ss and hold in Pressure and Weather Forecast Mode to view different bar charts Changes temperature and humidity display to selected channel Press and hold to enable cycling display of channel temperature and humidity Turns on backlight for 5s Enters Snooze mode when alarm is activated The following controls are only available on the main console unit OPEN LIGHT SENSOR AUTO ON OFF SENSITIVITY HIGH ...

Страница 11: ...pressure channel 1 temperature or channel 1 relative humidity Navigating between Different Modes There are 7 modes available on the main console unit and each one displays a different category of data When display is in a certain mode its corresponding icon will start flashing To navigate between the different modes from the main console unit press UP to cycle through the modes in a clockwise dire...

Страница 12: ...ast Moon phase UV Mode UV index Display or Minimal E Daily Maximum Display Weekly Maximum Display Clock and Alarm Mode Radio Controlled clock showing current time and calendar Single alarm weekday alarm and pre alarm Sunrise Sunset Mode Sunrise and sunset times Longitude and Latitude of local area ...

Страница 13: ...ected channel Comfort level Dew point Temperature alerts Rain Mode Precipitation amount for last hour last 24 hour yesterday last week and last month Rainfall alert Wind Mode Wind Chill Temperature at place of anemometer Wind direction Wind speed Wind gust Alert for wind speed and wind gust speed ...

Страница 14: ...switch at the back of the unit to select lighting preferences For the automatic backlight function the sensitivity of the light sensor can be adjusted to high or low with the sensitivity switch also on the back of the console unit Note Console unit must be powered with AC DC adaptor for automatic control function Linking the Weather Station to a Computer The Pro X has an internal memory of 3300 co...

Страница 15: ...con inHg or mmHg or hPa mBar should be flashing Press UP or DOWN to select pressure unit as inHg hPa mBar or mmHg Press SET to confirm your selection 2 Choose Altitude Units Press UP or DOWN to select altitude unit as feet or meters Press SET to confirm your selection 3 Set Altitude Press UP or DOWN to adjust value Press and hold either button for fast advance Press SET to confirm your selection 4...

Страница 16: ...e pressed for 5s the display automatically returns to Pressure and Weather Forecast Mode Viewing the Pressure Temperature Humidity Bar Charts The bar chart on the display can be configured to display the history data for sea level pressure temperature or humidity for channel 1 In Pressure and Weather Forecast Mode press and hold ALARM or press on the remote control to toggle the bar chart between ...

Страница 17: ...s clear weather Understanding the Moon Phase Diagram UV Mode The current UV intensity is indicated by both its numerical value and a more intuitive dis play by categorizing it into the levels LOW MED HIGH V HIGH and EXTREME It is also represented by a face icon that corresponds to the different levels The main console unit records the daily and weekly maximum UV intensity Values may be displayed i...

Страница 18: ...ted at specified time interval Fixed 30 min ahead of weekday alarm if channel 1 temperature falling to 2 ºC or below The snooze duration for the above alarms can also be programmed 0 15 min Accessing Clock and Alarm Mode From the main console unit Press UP or DOWN until the clock icon beside the time date display starts flashing From the remote control Press UV Index Level Intensity Protection 0 2...

Страница 19: ...e Option Press UP or DOWN to turn DST option on or off Press and hold either button for fast advance Press SET to confirm your selection 7 Repeat the above instructions to set year month day calendar display format day month or month day time display format 12 hr 24 hr local hour and local minutes 8 Upon completion the display will return to normal Clock and Alarm Mode Note Press and hold SET anyt...

Страница 20: ...er if the temperature of Channel 1 fall at 2 C or below Disabling Entering Snooze when Time Alarms are Activated To Enter Snooze Press LIGHT SNOOZE to enable snooze function Note Alarm will automatically enter snooze mode if no key is pressed after the alarm sounds for 2 minutes This will occur for a maximum of three times To Disable Alarm s Press ALARM to disable the alarm s Note For weekday alar...

Страница 21: ...or DOWN to select city code for your local area Refer to P XX for a list of available codes The corresponding longitude and latitude will be shown along with the city Should you wish to input your own geographical coordinates choose USR as the city code Press SET to confirm your selection 3 If USR was chosen you will be asked to input your geographical coordinates Set Degree of Latitude Press UP o...

Страница 22: ...splay The main console unit uses the indoor temperature and humidity data to compute a comfort level rating of Wet Comfort or Dry A temperature alert function is available for each channel It can be programmed to sound if the channel temperature exceeds or falls below the pre configured upper and lower limits Note The temperature alerts have a 0 5 ºC hysteresis to prevent the alerts from sounding ...

Страница 23: ...e Temperature Alerts 1 In Temperature and Humidity Mode press ALARM to select alarm which you wish to configure 2 Press and hold ALARM until channel temperature and or icon starts flashing in the display 3 Set Value for Temperature Alert Press UP or DOWN to adjust value Press and hold either button for fast advance Press ALARM to confirm your selection 4 Upon completion the display will be returne...

Страница 24: ...de From the main console unit Press UP or DOWN until the RAIN icon on the display starts flashing From the remote control Press Viewing Rain Statistics In Rain Mode each press of SET or MEM or MEMORY rotates display between different rain statistics Last hour Last 24 hour Yesterday Last week Last month Tip For an estimation of the rain rate the Last Hour rainfall value can be understood as inch hr...

Страница 25: ...imum values of wind speed and gust attained for the current day The wind speed and gust alert functions can be programmed to sound if the wind speed or gust exceeds a pre configured limit The wind speed may be displayed in km h mph m s or knots Note The wind speed alert has a 5 mph hysteresis and the wind gust speed alert has a 7 mph hysteresis The hysteresis is to prevent the alerts from sounding...

Страница 26: ...I displayed Gust alert GUST ALARM HI displayed If the alert is deactivated OFF will be shown otherwise the alert value is shown 2 When a wind alert is displayed pressing UP or DOWN will activate deactivate it Setting up the Wind Alerts 1 In Wind Mode press ALARM to select alarm which you wish to configure 2 Press and hold ALARM until alert and corresponding icon starts flashing in the display 3 Se...

Страница 27: ...on the main console unit Cleaning The main console unit and outer casings for the remote sensors can be cleaned with a damp cloth Small parts can be cleaned with a cotton tip or pipe cleaner Never use any abrasive cleaning agents and solvents Do not immerse any units with electronic parts in water or under running water Anemometer Check that the wind vane and wind cups can spin freely and are free...

Страница 28: ... vary considerably due to different environmental conditions and placement of weather sensors Check the placement tips included in this manual to site your sensors in the best possible way The weather forecast is inaccurate The weather forecast is a prediction of weather after 12 24 hours and may not reflect current weather conditions PRECAUTIONS This product is engineered to give you years of sat...

Страница 29: ...e applied standard s EN 300 200 3 2000 EN 300 200 1 2001 Electromagnetic compatibility Article 3 1 b of the R TTE Directive applied standard s EN 301 489 3 2002 EN 301 489 1 2004 SAR Applied standard s EN 50371 2002 Low voltage directive Applied standard s EN 60950 1 2001 Additional information The product is therefore conform with the Low Volatge Directive 73 23 EC the EMC Direc tive 89 336 EC an...

Страница 30: ...or AAA 1 5V battery Weight Main unit 231g without battery Remote Thermo Hygro unit 65g without battery Remote UV unit 79g without battery stand Remote Anemometer unit 315g without battery Remote Rain gauge unit 290g without battery IR Remote Control unit 90g without battery Dimension Main unit 220 L x 165 H x 32 D mm Remote Thermo Hygro unit 55 5 L x 101 H x 24 D mm Remote UV unit 66 L x 95 H x 66...

Страница 31: ...CA 5 SU Tampa Fla TPA 5 SU Vancouver Canada VAC 8 SU Toronto Ont Can YTZ 5 SU World Cities City Code Zone DST City Code Zone DST Offset Offset Addis Ababa Ethiopia ADD 3 NO Cairo Egypt CAI 2 sg Adelaide Australia ADL 9 5 SA Calcutta India CCU 5 5 NO as Kolkata Algiers Algeria ALG 1 NO Cape Town South Africa CPT 2 NO Amsterdam Netherlands AMS 1 SE Caracas Venezuela CCS 4 NO Ankara Turkey AKR 2 SE C...

Страница 32: ...A 8 NO Milan Italy MIL 1 SE Singapore Singapore SIN 8 NO Montevideo Uruguay MVD 3 SM Sofia Bulgaria SOF 2 SE Moscow Russia MOW 3 SK Stockholm Arlanda ARN 1 SE Sweden Munich Germany MUC 1 SE Sydney Australia SYD 10 SA Nairobi Kenya NBO 3 NO Tokyo Japan TKO 9 NO Nanjing Nanking NKG 8 NO Tripoli Libya TRP 2 NO China Naples Italy NAP 1 SE Vienna Austria VIE 1 SE New Delhi India DEL 5 5 NO Warsaw Polan...

Страница 33: ...re 20 C to 70 C 4 F to 158 F Temperature accuracy 1 C or 2 F Temperature resolution 0 1 C or 0 2 F Humidity Display Range 0 to 99 Humidity accuracy 5 within 25 80 Humidity resolution 1 Receiving Cycle Remote Thermo Hygro around 47s Rain gauge 183s Wind sensor 33s UV sensor 300s Sunrise and Sunset Accuracy 1min latitude within 50 UV range 0 0 UVI to 36UVI 15 4 MED hour UV resolution 0 1UVI 0 1 MED ...