Measuring step length
To determine your step length, proceed as follows:
- Walking: walk 10 steps as you normally would, then measure the distance covered and divide it by ten.
Example:
You measure 6.2 metres. 6.2m / 10 (number of steps) = 0.62m (input step length WALK: 62cm).
- Jogging: here, we recommend that you jog at least 50 steps and then use the distance covered in the
calculation.
Step counter
As soon as you start to walk (see “Important” in Chapter 3!), the steps you take are added and displayed.
The distance, kcal and movement time are counted automatically (see Chapter 4.2/4.4 – 4.6)
Reset (RESET) the measured data
Press and hold the RESET key for at least 4 seconds. All data in the current measurement are then deleted
(Chapter 4.1/4.3 – 4.4: steps, distance, kcal, movement time). You can perform this
RESET
in all these
functions. However, the data for this deleted measurement are stored in the
ODOSTEP
and the
STEP
TOTAL
counter!
Caution:
If you perform a
RESET
in the TOTAL STEP mode (Chapter 4.6), all measurement data, apart
from
ODOSTEP
, are reset to zero.
4.2
The function STEP (step counter)
As soon as you start to walk (see “Important” in Chapter 3!), the steps you take are added and displayed.
The distance, kcal and movement time are counted automatically (see Chapter 4.2/4.4 – 4.6)
Reset (RESET) the measurement data
Automatically: at midnight, the
STEP
counter (and the data in 4.4-4.6) is reset to zero.
Manually: press and hold the
RESET
key for at least 4 seconds. All data for the current measurement are
then deleted (Chapter 4.2 / 4.4– 4.6: steps, distance, kcal, movement time). You can perform this
RESET
in
all these functions. However, the data for this deleted measurement are stored in
STEP TOTAL
and
ODOSTEP
!
Caution:
If you perform a
RESET
in the
TOTAL STEP
mode (Chapter 4.6), the measurement data in the
daily memory (
STEP
) are also reset to zero. The data in
ODOSTEP
are retained.
4.3
The function
ODOSTEP
You can use this function to monitor a training unit with all measurement data.
While you are in the ODOSTEP, you have to start the function by pressing and holding the SET button (hold
for about 4 secs until "ODO" in the top left corner is flashing).
By doing this, you start resp. continue a "training session". You may interrupt the recording by holding the
SET button for about 4 secs again (then ODO stops flashing).
Select the measurement data: with the SET key
You can delete the ODOSTEP separately. Other RESETs (in STEP TOTAL or STEP) do not have any effect
on ODOSTEP.