Problem Solution

POOR DRAFT:

 

Extend chimney in length or have the chimney realigned to the proper size flue. Oversized chimneys normally have poor 

drafts. Remember, the appliances’ draft depends solely on the natural draft of the chimney (See Draft Requirements on 

Page 4). If your stove or fireplace insert is not drafting properly, your chimney is the problem. All stoves are thoroughly 

tested to ensure proper draft with the correct size chimney flue.

EXCESSIVE DRAFT:

 

With better chimneys being more common, excessive draft can be an issue. Alleviate excessive draft by slowing the 

burn rate of the appliance once it has reached proper operating temperature (See Maximizing Your Stoves Overall Ef-

ficiency on Page 19).

DIRTY GLASS:

 

1) Burn smaller, hotter fires and check to make sure you are not setting the draft down too far with the draft control.

 

2) Make sure your wood is well-seasoned and dry (not open to rain - see Creosote and Fuel sections on Pages 5-6).

 

3) See Poor Draft section (above) and Cleaning Glass on Page 20 .

SMOKES WHEN

 

1) If smoke is entering the room, check to make sure your baffle boards are properly installed 

DOOR IS OPEN:

 

 and that the baffle blanket is pushed back flush with the front of the baffle boards.

 

2) Check the chimney for blockage due to creosote (see Chimney and Creosote sections on Pages 5 and 7).

 

3) Check draft (See POOR DRAFT section above).

WOOD BURNS

 

1) The draft control must be closed further.

TOO FAST:

 

2) Add fuel at lower firebox temperatures.

 

3) Load wood side to side and reduce the flow of air under wood.

 

4) The door seal may need replacing, check for leakage.

 

5) See “Excessive Draft.”

POOR HEAT

 

1) Check your wood. Wet, moist, unseasoned wood will not produce heat.

OUTPUT:

 

2) Your stove or fireplace insert needs to be seasoned (moisture removed from the steel and brick). Continue to burn 

a fire. It normally takes from one to three weeks of burning to season your stove (See Burn-In Period on Page 6).

 

3) See Excessive Draft section above.

PAINT GIVES OFF

 

Paint is tempering-in. Burn only moderately hot for the first few days until paint is fully cured.

ODOR (smoke): 

Then burn a very hot fire to cure any paint that may not easily cure. Open windows or door to ventilate (See Burn-In 

Period on Page 6).

TROUBLESHOOTING

Содержание Striker S160

Страница 1: ...18 A French manual is available upon request Order P N 900127 00 Ce manuel d installation est disponible en francais simplement en faire la demande Num ro de la pi ce 900127 00 This appliance must be...

Страница 2: ...for Installation 7 Installation Clearances 8 Typical Installation Figures 9 Chimney Installation 10 USING THIS MANUAL Please read and carefully follow all of the instructions found in this manual Plea...

Страница 3: ...g season to check for soot and creosote accumulations Any accumulations over 1 8 thick should be removed by a professional chimney sweep Do not attempt to burn out heavy creosote accumulations with a...

Страница 4: ...he actual vertical vent height to determine your effective draw In this case if you had 14 feet of vertical vent the effective draw would only be approximately 9 feet 14 ft 5 ft 9 ft therefore it may...

Страница 5: ...a steel container with a tight fitting lid and moved outdoors immediately Other waste shall not be placed in this container The closed container of ashes should be placed on a non combustible floor o...

Страница 6: ...THE AMOUNT OF AIR ENTERING THE STOVE IMMEDIATELY BURN IN PERIOD PAINT CURING 4 4 8 Standard Cord of Wood 8 Ft 2 4M 4 Ft 1 2M 4 Ft 1 2M Thisapplianceisdesignedtoburndryseasonednaturalwoodonly see Page...

Страница 7: ...Shield attaches to rear of stove pipe and must run from stove top to ceiling Pipe shield shall be UL listed Residential chimney systems must be from the same brands as listed for mobile homes but conn...

Страница 8: ...m 72 1829mm USA 8 200mm from door opening Canada 8 200mm from sides and back of unit u Dimensions to Stove Body v Clearances may only be reduced by means approved by the regulatory authority Mobile Ho...

Страница 9: ...ure 5 Typical Installation Figure 6 Connected to a Masonry Chimney Floor Protector Floor Protector Fasten each stove pipe connection with at least 3 sheet metal screws Single wall stove pipe must not...

Страница 10: ...nted to the masonry or be installed without cement in a thimble connected to the masonry wall When the connector is inserted into a thimble the joint must be tight enough so that it will not be dislod...

Страница 11: ...ll be 12 in 305 mm Chimney section concentric with and spaced 1 in 25 4 mm away from connector by means of sheet steel support plates on both ends of chimney section Opening shall be covered and chimn...

Страница 12: ...the contents upon receipt and check for any damaged or missing parts If there is hidden damage notify your freight company or IHP dealer immediately CAUTION Wear gloves during installation in case of...

Страница 13: ...the floor if so desired Slip the flexible outside air tube through the hole in the floor leaving 1 of tube above the floor protector surface using tape to hold it in place 6 Place the stove on the fl...

Страница 14: ...pper wire or equivalent 11 Install bricks as per instructions on Pages 15 and 16 It is highly recommended that the baffle be assembled before the chimney is installed so that the baffle blanket can be...

Страница 15: ...he baffle boards so as not to block exhaust flow to the flue Use a ruler or a piece of kindling to reach over the baffle blanket to be sure it is completely flat on top of the baffle boards Measure br...

Страница 16: ...the front to rear of the firebox Start by setting the back side of the board on the rear baffle making sure that it is placed far enough back to lift up and onto the front baffle Next you will place...

Страница 17: ...l tool to help ensure you are not over firing your appliance and it will also ensure you are burning fuel at a rate that is most efficient Place a stove thermometer on the top of the appliance Monitor...

Страница 18: ...ot enough to effectively heat the air moved by the blower If the air coming from the blower feels cool one should either decrease the blower speed or stoke the fire to build up more heat NOTE Turn blo...

Страница 19: ...d the appliance let the appliance top cool down to 275 to 400 degrees on Elites locatethermometeronthefaceoftheinsertjustabovethedoor Now load the firebox and set the draft control At this point you m...

Страница 20: ...pected at least once a year by a qualified service technician to ensure gaskets air tubes baffles and venting are in good repair to ensure proper performance Have degraded items replaced by a qualifie...

Страница 21: ...r burns more build up Higher burns less build up Keep freshly loaded wood away from the glass After reloading allow all the wood to catch flame before dampering down the appliance GLASS REPLACEMENT IN...

Страница 22: ...20 SMOKES WHEN 1 If smoke is entering the room check to make sure your baffle boards are properly installed DOOR IS OPEN and that the baffle blanket is pushed back flush with the front of the baffle b...

Страница 23: ...nts in your area Carbon Monoxide Monitor Recommended Carbon Monoxide Poisoning Early signs of carbon monoxide poison ing are similar to the flu with headaches dizziness and or nausea If you have these...

Страница 24: ...tside Air Plenum Box FSB BLOWER PARTS 25 H8062 FSB700 Blower Only Assembly w blower wiring harness 26 H5658 Fan Blade FSB700 27 H5657 Fan Cage FSB700 28 H8063 FSB700 Blower Only Wire Harness 29 H8064...

Страница 25: ...25 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE 25 REPLACEMENT PARTS MODELS S160 AND SA160...

Страница 26: ...26 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE REPLACEMENT PARTS MODELS S160 AND SA160 Door Parts Blower Parts 7 13 1 2 3 4 5 6 8 1 2 3 4 5 9 10 8 14 11 6 7 12 25 29 31 28 27 26 32 30...

Страница 27: ...27 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE REPLACEMENT PARTS MODELS S160 AND SA160 22 24 18 20 21 23 Leg and Leg Parts...

Страница 28: ...28 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE REPLACEMENT PARTS MODELS S160 AND SA160 15 18 15 18 19 16 17 19 Ash Drawer Pedestal and Pedestal...

Страница 29: ...pic Sculptured Nickel 4 per pkg 70008 LEG OLY BRN Olympic Sculptured Brushed Nickel 4 per pkg 70003 LEG CAS B Cascade Steel Black 4 per pkg HEAT SHIELD REQUIRED WITH LEGS 71110 WSHS 160 Heat Shield re...

Страница 30: ...ctured By INNOVATIVE HEARTH PRODUCTS 1502 14th St NW Auburn WA 98001 USA PREVENT HOUSE FIRES Install and use only in accordance with manufacturer s installation and operating instructions and your loc...

Страница 31: ...inder may burn at excessive temperatures and may cause damage to the Product or may cause it to function improperly IHP stoves inserts and high efficiency EPA fireplaces are approved for burning dry s...

Страница 32: ...he Serial Number of the appliance 3 The part number 4 The description of the part 5 The quantity required 6 The installation date of the appliance If you encounter any problems or have any questions c...

Отзывы: