IronStrike Performer C210 Скачать руководство пользователя страница 20

20

DO NOT:

 

Install or operate the appliance before reading this manual.

 

  

DO NOT:

 

Close the draft beyond the point at which the flames are 

completely extinguished.

DO NOT:

 

Open the appliance door without fully opening the draft first.

DO NOT:

 

Burn driftwood or wood that has been in salt water. This 

includes some mill ends and scrap lumber that has been 

floated in salt water on the way to the mill. (This will void 

your warranty).

DO NOT:

  Handle the plated faceplate unnecessarily. Use the door 

handle only.

DO NOT:

 

Force oversized logs into the firebox as this may dislodge 

the baffle assembly.

DO NOT:

 

Close the door tightly during Burn-In period.

DO:

 

Be sure to clean any fingerprints from optional accessories 

that have plated surfaces before burning the appliance. Clean 

the plated surfaces only with household type glass cleaner 

and a very soft cloth.

DO:

 

Consult local building department if other than recommended 

clearances are desired.

DO:

 

Read instructions for the baffle boards and baffle blankets 

occasionally to ensure you have not bumped or moved them 

out of place when loading wood.

DO

Check the chimney and baffle monthly to make sure they 

are clean.

DO

Burn seasoned, dry wood only! (RAIN = WET WOOD) 

DO

Open the door frequently during Burn-In period to keep 

gasket from adhering to the curing paint.

DO:

 

Enjoy the warm feeling of your new IHP appliance.

DO’S AND DON’TS

Smoke Detector Recommended

Since there are always several potential sources of fire in any home, we 

recommend installing smoke detectors. If possible, install the smoke 

detector in a hallway adjacent to the room (to reduce the possibility of 

occasional false activation from the heat produced by these appliances). 

If your local code requires a smoke detector be installed within the same 

room, you must follow the requirements of your local code. Check with 

your local building department for requirements in your area.

Carbon Monoxide Monitor Recommended

Carbon Monoxide Poisoning

: Early signs of carbon monoxide poison-

ing are similar to the flu with headaches, dizziness and/or nausea. If you 

have these signs, obtain fresh air immediately. Some people are more 

affected by carbon monoxide than others, including pregnant women, 

people with heart or lung disease or anemia, those under the influence 

of alcohol, and those at high altitudes.

It is against federal regulations to operate wood heaters in a man-

ner inconsistent with operating instructions in the manual.

PROHIBITED FUELS

This heater is designed to burn natural wood only. Higher efficiencies 

and lower emissions generally result when burning air dried seasoned 

hardwoods, as compared to softwoods or to green or freshly cut hard-

woods. DO NOT BURN:

•  Garbage;

•  Lawn clippings or yard waste;

•  Materials containing rubber, including tires;

•  Materials containing plastic;

•  Waste petroleum products, paints or paint thinners, or asphalt products;

•  Materials containing asbestos;

•  Construction or demolition debris;

•  Railroad ties or pressure-treated wood;

•  Manure or animal remains;

•  Salt water driftwood or other previously salt water saturated materials;

•  Unseasoned wood;

•  Christmas tree branches;

•  Paper products, colored paper, cardboard, plywood, or particleboard; 

•  gasoline;

•  naphtha;

•  engine oil; 

•  flammable liquids; 

•  solvents;

•  grease; or

•  coal

The prohibition against burning these materials does not prohibit the use 

of fire starters made from paper, cardboard, saw dust, wax and similar 

substances for the purpose of starting a fire in an affected wood heater.

Burning these materials may result in release of toxic fumes or render the 

heater ineffective and cause smoke. Intense firing with these materials 

may overheat the fireplace, causing damage to the unit, a fire or even 

possibly igniting a chimney fire if the chimney is creosoted.  Burning 

unapproved fuel, resulting in excessive pollutants being emitted, may be 

prohibited and subject to a fine or other penalty by the authority having 

jurisdiction in your area.

Содержание Performer C210

Страница 1: ...ro de la pi ce 900102 00 This appliance must be properly installed and operated in order to prevent the possibility of a house fire Please read this entire installation and operation manual before ins...

Страница 2: ...Chimney Requirements 10 Installation Procedures Masonry Chimney 10 Positive Flue Connection 11 Installation Procedure Factory Built Zero Clearance Fireplaces 11 Fireplace Pre Installation Preparation...

Страница 3: ...by a professionalchimneysweep Donotattempttoburnoutheavy creosoteaccumulationswithahotfire Iflargeaccumulations are occurring review your burning procedures 14 If a creosote fire should develop the fi...

Страница 4: ...ccessories may turn color stove glass may develop a haze which will not come off with cleaning Overfiring of a stove or fireplace insert is a condition where excessive temperatures are reached beyond...

Страница 5: ...tion is essential when using a Solid Fuel Burning heater In well insulated and weather tight homes it may be difficult to establish a good draft up the chimney caused by a shortage of air in the home...

Страница 6: ...f three burns The first two should last for 20 minutes each at 250 degrees the appliance should be allowed to cool completely between each burn The third should be a burn of at least 450 degrees F for...

Страница 7: ...nstall the two remaining boards where you originally installed the first two boards on each side of the baffle support and pushed against the rear of the unit The stainless steel support hanger should...

Страница 8: ...from the door opening of the unit Canada 18 450 mm minimum hearth extension on all stoves and inserts as measured from the door opening of the unit Minimum distance of floor protection to the side 8...

Страница 9: ...asterisk indicates it is a value taken from Tables 2 and 3 FOLLOWING EXAMPLES ARE CALCULATED FOR USA REQUIRMENTS Using the k formula Minimum k value per Inch of Specified min thickness of alternate ma...

Страница 10: ...nter of the fireplace opening and push it back until the surround brackets are approximately 2 51 mm away from the fireplace front 7 Install the side surround panels and push the insert up snug agains...

Страница 11: ...pproved methods of achieving a positive flue connection See Figure 9 A qualified installer should evaluate the existing fireplace to determine the best method for achieving a positive flue connection...

Страница 12: ...Factory Built Zero Clearance Fireplaces Fireplace Pre Installation Preparation NOTE IHP RECOMMENDS PROFESSIONAL INSTALLATION BY A LICENSED AND BONDED INSTALLER SEE YOUR DEALER FOR RECOMMENDATIONS IMP...

Страница 13: ...Part H5296 is available to fill the space between the insert and the hearth protection Install the brick and baffle as per Page 7 Chimney Liner Installation Installing the Insert Post Installation Ch...

Страница 14: ...ermometer can be a helpful tool to help ensure you are not over firing your appliance and it will also ensure you are burning fuel at a rate that is most efficient Place a stove thermometer on the top...

Страница 15: ...turn off continue to rotate the knob counterclockwise until it clicks OFF Blower Speed Control Knob rheostat Manual Auto Rocker Switch Blower Operation Guidelines While in auto operation mode the blo...

Страница 16: ...locate thermometer on the face of the insert just above the door Now load the firebox and set the draft control At this point you may need to burn the fireplace insert with the draft open for a few m...

Страница 17: ...are included with the graphite CAUTION Cleaning Glass Ensure appliance is cold prior to cleaning glass A commercial glass cleaner designed for stoves is recommended Do not use abrasivecleaners Donotc...

Страница 18: ...rotective gloves are recommended Step 5 Install New Glass Assembly Install the new glass with gasket in recess on door back use only factory supplied 5mm ceramic glass Do not substitute Step 6 Reinsta...

Страница 19: ...ss above SMOKES WHEN 1 If smoke is entering the room check to make sure your baffle boards are properly installed DOOR IS OPEN and that the baffle blankets are pushed back flush with the front of the...

Страница 20: ...requirements in your area Carbon Monoxide Monitor Recommended Carbon Monoxide Poisoning Early signs of carbon monoxide poison ing are similar to the flu with headaches dizziness and or nausea If you...

Страница 21: ...dware 18 H8082 Replacement Power Cord 19 H8074 UHPII Blower Cage Snap Switch Black H8075 UHPII Blower Cage Snap Switch Gold H8076 UHPII Blower Cage Snap Switch Nickel H8077 UHPII Blower Cage Snap Swit...

Страница 22: ...22 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE 33 34 36 36 45 46 47 37 37 35 40 44 40 38 38 38 41 38 38 38 41 38 38 42 38 38 38 38 42 38 38 39 39 43 39 39 Replacement Parts Model C210 and CA210...

Страница 23: ...23 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE 7 13 1 2 3 4 5 6 8 1 2 3 4 5 9 10 8 14 11 6 7 12 16 29 17 15 32 18 19 Replacement Parts Model C210 and CA210 Door Parts Blower Parts...

Страница 24: ...N 71021 WFT2640 B Black 26 3 4 x 40 71022 WFT2648 B Black 26 3 4 x 48 71025 WFT3040 B Black 30 3 4 x 40 71026 WFT3048 B Black 30 3 4 x 48 71007 WFT2640 G Gold 26 3 4 x 40 71008 WFT2648 G Gold 26 3 4 x...

Страница 25: ...a binder may burn at excessive temperatures and may cause damage to the Product or may cause it to function improperly IHP stoves inserts and high efficiency EPA fireplaces are approved for burning d...

Страница 26: ...a complete replacement parts list Use only parts supplied from the manufacturer Normally all parts should be ordered through your IHP distributor or dealer Parts will be shipped at prevailing prices a...

Отзывы: