3.  First, screw the threaded rods into the holes at the four corners on the 

bottom of the stove. Screw the threaded rods into the firebox three 

full rotations or 3/16” to 1/4” (

if the rear rods are screwed in too far 

they will lift the bricks off the bottom of the stove)

. Use a washer 

and nut to secure the leg. Be sure the  legs are mounted squarely on 

the firebox bottom. Tighten nuts securely.

4. Use the two bolts and washers provided with the heatshield kit to 

mount the heatshield as shown in 

Figure 10

.

5.  Do not over tighten the heatshield mounting bolts as it may bend the 

heatshield.

To locate the hole in the hearth for outside air, mark a 4” circle on the 

hearth. The circle’s center should be 2-3/4” directly back from the center 

of the flue outlet and 5/8” to the left side.

Figure 11

Expanded View 

of Clip

Residential and Mobile Homes - 

Bolting down and grounding of  stove 

are required only in mobile homes.

Open all cartons, if any and remove the contents upon receipt and check 

for any damaged or missing parts. If there is hidden damage, notify your 

freight company or IHP dealer immediately.

CAUTION:  Wear gloves during installation in case of sharp 

edges on the stove.

Leg Installation

1.  Carefully place stove on its back. Be careful not to scratch the stove, 

use a piece of cardboard or carpet to protect the back of the stove.

2. Mount all four legs as shown in 

Figure 9

.

Line up the hole in the clip with the hole in the 

rear center of the bottom heatshield

LEG AND HEATSHIELD INSTALLATION

OUTSIDE AIR KIT INSTALLATION

To install the “Outside Air Kit”, position the clip so that the nut is directly 

above the hole punched in the back of the heatshield (see 

Figure 11

)

Install the outside air adapter box on the stove by sliding it into the air 

channel located between the bottom heatshield and the stove bottom until 

the oblong ring is approximately 1/4” from the rear edge of the lower 

heatshield. Make sure the ring is facing down. Thread the bolt up through 

the nut in the clip until snug against the adapter box.

Threaded Rod

Washer

Nut

Air Channel

Heat Shield 

Mounting Holes

FRONT

BACK

 Clip

1/4” Bolt

Содержание Legacy S260 T-Top

Страница 1: ...h manual is available upon request Order P N 900131 00 Ce manuel d installation est disponible en francais simplement en faire la demande Num ro de la pi ce 900131 00 This appliance must be properly i...

Страница 2: ...em 4 Negative Pressure Warning 5 Creosote 5 Disposal of Ashes 5 Fuel 5 Burn In Period 5 Paint Curing 5 Clearances to Combustibles 6 7 Floor Protection 6 7 Reduced Clearances 6 Alcove Clearances 6 Chim...

Страница 3: ...g the burn ing season to check for soot and creosote accumulations Any accumulations over 1 8 thick should be removed by a professionalchimneysweep Donotattempttoburnoutheavy creosoteaccumulationswith...

Страница 4: ...e too restrictive see Chimney Guide lines Inadequate draft will cause the appliance to leak smoke into the room through the stove and the chimney connector joints Excessive draft may cause an uncontro...

Страница 5: ...should be placed on a non combustible floor or on the ground well away from all combustible materials pending final disposal If the ashes are disposed of by burial in soil or otherwise locally disper...

Страница 6: ...ons utilizing a 8 to 6 reducer cat 71134 at the flue collar If the venting system is all vertical and the total vent length above the flue outlet exceeds 14 feet it is recommended that the 8 to 6 pipe...

Страница 7: ...28 711mm 18 450mm 8 200mm 13 330mm 23 584mm USA 37 1 4 CAN 1200mm 8 Double Wall Residential or Mobile Home 16 406mm 13 1 2 343mm 25 635mm 15 381mm 8 200mm 12 305mm 22 559mm USA 37 1 4 CAN 1200mm 8 Do...

Страница 8: ...r Figure 5 Typical Installation Figure 6 Connected to a Masonry Chimney Floor Protector Floor Protector Fasten each stove pipe connection with at least 3 sheet metal screws Single wall stove pipe must...

Страница 9: ...ermination All mobile home installa tions require an outside air kit see Page 27 for ordering information and the stove must be secured to the floor and grounded to the mobile home chassis Install Out...

Страница 10: ...ll be 12 in 305 mm Chimney section concentric with and spaced 1 in 25 4 mm away from connector by means of sheet steel support plates on both ends of chimney section Opening shall be covered and chimn...

Страница 11: ...all cartons if any and remove the contents upon receipt and check for any damaged or missing parts If there is hidden damage notify your freight company or IHP dealer immediately CAUTION Wear gloves...

Страница 12: ...rew in that leg as well 9 Install bricks and baffle as per instructions on Page 15 It is highly recommended that the baffle be assembled before the chimney is installed so that the baffle blanket can...

Страница 13: ...th The hole s center should be 3 76 mm directly forward from the center of the flue outlet or locate as per the instructions below 6 Position the stove on your floor protection in the exact location w...

Страница 14: ...tside air vent has been sealed properly to keep rodents out if applicable 5 Be sure all roof flashings are watertight 6 Be sure the stove is properly grounded if applicable FOR YOUR OWN PROTECTION AND...

Страница 15: ...stalling the front baffle boards The front baffle boards will be the two remaining baffle boards which are the larger two baffle boards of the four baffle board kit They will be installed with the 9 5...

Страница 16: ...re not over firing your appliance and it will also ensure you are burning fuel at a rate that is most efficient Place a stove thermometer on the top of the appliance Monitor the temperature every 15 m...

Страница 17: ...ensure uninterrupted blower operation For example a small fire may require a slower blower speed to keep the heat output by the blower consistent If the blower is operated in manual mode it may be ne...

Страница 18: ...top cool down to 275 to 400 degrees on Elites locate thermometer on the face of the insert just above the door Now load the firebox and set the draft control At this point you may need to burn the sto...

Страница 19: ...up while holding the op posite side of the door Lift door out of the lower hinge pin and place face down on a soft surface Step 2 Remove Door Back Screws 6 ea Using a 5 32 allen wrench remove the 6 r...

Страница 20: ...Glass on Page 19 SMOKES WHEN 1 If smoke is entering the room check to make sure your baffle boards are properly installed DOOR IS OPEN and that the baffle blanket is pushed back flush with the front o...

Страница 21: ...ffle assembly DO NOT Close the door tightly during Burn In Period DO Be sure to clean any fingerprints from optional accessories that have plated surfaces before burning the appliance Clean the plated...

Страница 22: ...enum Box FSB BLOWER PARTS Item Cat No Description 25 H8062 FSB700 Blower Only Assembly w blower wiring harness 26 H5658 Fan Blade FSB700 27 H5657 Fan Cage FSB700 28 H8063 FSB700 Blower Only Wire Harne...

Страница 23: ...23 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE Replacement Parts Model S260...

Страница 24: ...24 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE Door Parts Blower Parts 25 29 31 28 27 26 32 30 Replacement Parts Model S260 7 11 10 6 9 5 4 4 1 8 2 3...

Страница 25: ...25 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE Replacement Parts Model S260 22 24 18 20 21 23 Leg and Leg Parts...

Страница 26: ...26 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE Replacement Parts Model S260 15 18 15 18 19 16 17 19 Ash Drawer Pedestal and Pedestal...

Страница 27: ...AMEPLATE F1870 TRAD FPK BG LG Large Traditional Faceplate Kit Brushed Gold F1869 TRAD FPK G LG Large Traditional Faceplate Kit Gold BLOWER H7917 BLWR FSB700 SS Blower Kit FS Woodstoves OUTSIDE AIR KIT...

Страница 28: ...28 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE SAFETY LISTING LABEL eNGLISH 2013 2014 2015 Innovative Hearth Products LLC 1502 14th St NW Auburn WA USA 98001...

Страница 29: ...29 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE SAFETY LISTING LABEL FRENCH Innovative Hearth Products LLC 1502 14th St NW Auburn WA USA 98001...

Страница 30: ...30 NOTES...

Страница 31: ...a binder may burn at excessive temperatures and may cause damage to the Product or may cause it to function improperly IHP stoves inserts and high efficiency EPA fireplaces are approved for burning d...

Страница 32: ...ways give the following information 1 The model number of the appliance 2 The Serial Number of the appliance 3 The part number 4 The description of the part 5 The quantity required 6 The installation...

Отзывы: