21
5. Checking 90º accuracy between the 2 Vertical beams.
This procedure requires a room of at least 5x5 meters with 3 walls.
1) Set up the laser on a table or on the floor in the middle of the room.
2) Unlock the pendulum and press the button Beam Selector (a)
twice, to project the forward and the side vertical beams
3) Mark the center of the side vertical beam in 3 places;
• Point
a1
on the left wall
A
, in the middle of the vertical line.
• Point
b1
on the right wall
B
, in the middle of the vertical line.
• Point
c1
on the table, in the middle of the cross lines of the 2
verticals.
4) Mark the point
c2
on the front wall
C
, in the middle of the vertical
line (see figure # 7).
102494