background image

page

 8

MATRIX II K

www.ironlogic.

me

Lock

ZUMM
TM
GND
EXIT
LED
LOCK
+12V
GND
DOOR

ADD

CLR

Optional external devices to connect: 
-  External buzzer;
-  External LED;
-  External button;
-  Door sensor.

Door sensor

button

External buzzer

External LED

12V 
DC

Figure 5. Connecting external devices

+12V
GROUND
DATA 0
DATA 1
LED-G
LED-R
BEEP

ZUMM
TM
GND
EXIT
LED
LOCK
+12V
GND
DOOR

ADD

CLR

Matrix II

 К

Matrix II

Figure 4. Connecting

 

an external reader.

ZUMM
TM
GND
EXIT
LED
LOCK
+12V
GND
DOOR

ADD

CLR

TM

Matrix II

 К

Recommended diodes: 
1N5400, 1N5821, HER301.

Probe

Figure 7. Connecting a protective diode.

Figure 6. Connecting a probe.

Lock

+12V

Содержание Matrix II

Страница 1: ... frequency 125 kHz Keys key fobs standard EM Marine Maximum number of keys cards 1364 Built in EEPROM Present Reading distance 2 8 cm Power supply operating voltage 12 V DC Maximum operating current 45 mA Power output for lock Field effect transistor Maximum switching current for power output 5 A Jumper for lock type selection Yes Electromechanical or electromagnetic positions Lock release duratio...

Страница 2: ... Matrix II K programming and never for access Normal Access card used for passing through access point except Blocking Mode Blocking card used for both passing through access point including Blocking Mode and toggling the Blocking Mode on off Note The Blocking cards open the lock when they are being taken away from the reader Initially the memory of the controller part of a Matrix II K device is e...

Страница 3: ...se duration or until the door sensor is triggered Absent from Matrix II K controller database the LED blinks 3 4 times alternating between green and red the buzzer sounds 4 PROGRAMMING When describing programming procedures it is convenient to use the term card touch to the reader which we define as swiping the reader with a card close enough for reliable card ID acquisition up to 2 cm Initial Mat...

Страница 4: ...mits a short beep acknowledging the Master card recognition Within 6 s touch and hold the Master card at the reader long touch On that touch the controller emits two short beeps acknowledging the second Master card touch and in 6 s one more beep acknowledging that controller is now in Add Master Card mode Take away the Master card now To add more Master cards keep touching the reader with new card...

Страница 5: ...hen the entire database is being erased with a Master card the programmed Lock Release Time is not reset Mode 5 Lock Release Time Programming 4m Touch the reader 4 times with a Master card On each touch the reader emits beeps acknowledging Master card recognition their count corresponds to the number of the touch So on fourth touch the reader emits four short beeps and enters the Lock Release Time...

Страница 6: ...edging the Master card touch Within 6 s touch and hold the Master card at the reader long touch The reader emits two short beeps acknowledging second Master card touch then in 6 s a beep showingAdd Master Card mode activated on the device Now touch the probe with DS1996L key and hold it until a series of short beeps sounds That would copy all keys information stored in the controller the database ...

Страница 7: ...d to the lock and Unlocked no voltage being supplied to the lock To toggle between these positions touch the reader with any Normal or Blocking card present in the device database The controller acknowledges the position toggle Unlocked to Locked one short beep Locked to Unlocked series of short beeps The managed lock should be connected to LOCK and 12V terminals on the Matrix II K reader Notice D...

Страница 8: ...ternal buzzer External LED 12V DC Figure 5 Connecting external devices 12V GROUND DATA 0 DATA 1 LED G LED R BEEP ZUMM TM GND EXIT LED LOCK 12V GND DOOR ADD CLR Matrix II К Matrix II Figure 4 Connecting an external reader ZUMM TM GND EXIT LED LOCK 12V GND DOOR ADD CLR TM Matrix II К Recommended diodes 1N5400 1N5821 HER301 Probe Figure 7 Connecting a protective diode Figure 6 Connecting a probe Lock...

Страница 9: ...0 2 Wall plugs 2 9 LIMITED WARRANTY Device is covered by limited warranty for 24 months The warranty becomes void if this Manual is not followed device has physical damage device has visible traces of aggressive chemicals exposure device circuits have visible traces of tamper by unauthorised parties While covered the Manufacturer will repair the device or replace any broken parts free of charge wh...

Страница 10: ...uce the consumption of raw materials thus protecting the environment page 10 MATRIX II K www ironlogic me 10 IRONLOGIC CONTACTS Headquarters RF Enabled ID Limited 34 Ely Place London EC1N 6TD UK E mail marketing rfenabled com Development and production AVS LLC 7 Bobruiskaya street Saint Petersburg 195009 Russian Federation E mail marketing rfenabled com Phone 78122411853 78125421185 www ironlogic ...