For Warranty Service Call 866-359-7378             Revision IR20191009                            Page 9 
 

 

Step #5: Gas Connection 

 
A 3/4" male NPT line for the gas connection is located near the lower right rear corner of the fryer. The 
serial plate (located inside the front door of the fryer) indicates the type of gas the unit is equipped to burn 
(natural gas or propane). The fryer should be connected ONLY to the type of gas for which it is equipped. 
 
A circuit diagram is located inside the front door of the fryer. 
 
All IRON RANGE equipment is adjusted at the factory; however, pilot height should be checked at 
installation and adjusted, if necessary. 
 
For orifice sizes and pressure regulator settings, see the chart on page 4. If the fryer is being installed at 
over 2,000 feet altitude and that information was not specified when ordered, contact the appropriate 
authorized IRON RANGE Service Representative or the IRON RANGE Service Department. Failure to 
install with proper orifice sizing will result in poor performance and may void the warranty. 
 
If applicable, the vent line from the gas appliance pressure regulator shall be installed to the outdoors in 
accordance with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI 
Z223.1, Natural Gas Installation Code, CAN/CGA-B149.1, or the Propane Installation Code, CAN/CGA- 
B149.2, as applicable. 
 
An adequate gas supply is imperative. Undersized or low pressure lines will restrict the volume of gas 
necessary for satisfactory performance. A combination gas valve and pressure regulator, which is provided 
with each unit, is set to maintain a 4" W.C. manifold pressure for natural gas or 10.0" W.C. manifold 
pressure for propane gas. However, to maintain these conditions the pressure on the supply line, when all 
units are operating simultaneously, should not drop below 7" W.C. for natural gas or 11" W.C. for propane 
gas. Fluctuations of more than 25% on natural gas or 10% on propane gas will create problems and affect 
burner operating characteristics. A 1/8" tap to measure the manifold pressure is located on the combination 
gas valve and on the burner manifold, which is on the burner manifold located directly below the burners 
inside the cabinet. 
 
Purge the supply line to clean out dust, dirt, or other foreign matter before connecting the line to the unit.    
 
It is recommended that an individual manual shutoff valve be installed in the gas supply line to the unit.  
 
Use pipe joint compound that is suitable for use with both natural and LP gas on all threaded connections. 
 

 

ALL PIPE JOINTS AND CONNECTIONS MUST BE TESTED THOROUGHLY FOR GAS LEAKS. USE 

ONLY SOAPY WATER FOR TESTING ON ALL GASES. NEVER USE AN OPEN FLAME TO CHECK 

FOR GAS LEAKS. ALL CONNECTIONS MUST BE CHECKED FOR LEAKS AFTER THE UNIT HAS 

BEEN PUT INTO OPERATION. 

TEST PRESSURE SHOULD NOT EXCEED 12" W.C.

 

 

 

THIS APPLIANCE AND ITS INDIVIDUAL COMBINATION GAS VALVE MUST BE DISCONNECTED 

FROM THE GAS SUPPLY PIPING SYSTEM DURING ANY PRESSURE TESTING OF THAT SYSTEM 

AT TEST PRESSURES IN EXCESS OF 14”WC (1/2 PSIG or 3.45 kPa). 

 

If the incoming gas pressure is in excess of 14"WC (1/2PSI, 3.45 kPa), a proper step-down regulator will 

be required. 

 

Содержание IRF-40LPG

Страница 1: ... s Manual Installation Guide Models covered in this manual are IRF 40NAT IRF 40LPG IRF 50NAT IRF 50LPG IRF 75NAT IRF 75LPG Improper installation adjustment alteration service or maintenance can cause property damage injury or death Read the installation operating and maintenance instructions thoroughly before installing or servicing this equipment ...

Страница 2: ..._____________ Model Number _________________________________ Serial Number ______________________________________ For Warranty Service please call 866 359 7378 For Technical Support 800 228 7253 or email techsupport ironrange co BE SURE TO HAVE MODEL NUMBER AND SERIAL NUMBER AVAILABLE WHEN CALLING FOR SERVICE OR PARTS REGISTER YOUR WARRANTY ONLINE AT www ironrange co Attach a copy for your proof o...

Страница 3: ...must be fully understood even though not dangerous FIRE HAZARD FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance Keep area around appliances free and clear of combustibles Purchaser of equipment must post in a prominent location detailed instructions to be followed in the event the operator smells gas Obtain the instru...

Страница 4: ... FUTURE REFERENCE MODELS This manual is for IRON RANGE Gas Floor Model Fryers with 40 pound IRF 40 50 pound IRF 50 and 75 pound IRF 75 capacities The capacity is described on the serial plate that is located on the inside of the front door TABLE OF CONTENTS Gas Supply and Burner Information Page 5 Installation Page 5 Operation Page 11 Cooking Hints Page 13 Cleaning Page 14 Parts Page 16 Read these...

Страница 5: ...ll be void Local codes regarding installation vary greatly from one area to another The National Fire Protection Association Inc states in its NFPA 96 latest edition that local codes are the authority having jurisdiction when it comes to installation requirements for equipment Step 1 Unpack IMMEDIATELY INSPECT FOR SHIPPING DAMAGE All containers should be examined for damage before and during unloa...

Страница 6: ...be screwed in or out to lower or raise each corner of the fryer 5 Attach restraints as required by local codes Unit must be level to assure maximum performance and proper ventilation Improper leveling may void warranty This appliance must be installed with the casters supplied a connector complying with either ANSI Z21 69 CSA 6 16 and a quick disconnect device complying with ANSI Z21 41 CSA 6 9 It...

Страница 7: ...0191009 Page 7 Step 3 Flue Installation 1 Unpack the flue box and flue wrap 2 Slide the flue box over the flue and secure it with the two self tapping screws using a 5 16 socket 3 Slide the flue wrap over the flue 4 Secure it with four self tapping screws two on the back and one on each side using a 5 16 socket ...

Страница 8: ...r that the flow of combustion and ventilation air is not obstructed Provisions for adequate air supply must also be provided Do NOT obstruct the bottom front of the unit as combustion air enters through this area Be sure to inspect and clean the ventilation system according to the ventilation equipment manufacturer s instructions Due to the variety of problems that can be caused by outside weather...

Страница 9: ...f gas necessary for satisfactory performance A combination gas valve and pressure regulator which is provided with each unit is set to maintain a 4 W C manifold pressure for natural gas or 10 0 W C manifold pressure for propane gas However to maintain these conditions the pressure on the supply line when all units are operating simultaneously should not drop below 7 W C for natural gas or 11 W C f...

Страница 10: ...ector or a soapy water solution is recommended for locating gas leaks Matches candle flame or other sources of ignition shall not be used for this purpose Check entire piping system including the internal piping and Pipe Union inside of the fryer for leaks DO NOT use an open flame to check for leaks Check all gas piping for leaks with a soap and water solution before operating the unit After conne...

Страница 11: ...nside the front door 4 Remove the basket support frame when filling the frypot with solid shortening 5 When solid shortening is used be careful not to bend break or twist the thin capillary wires of the sensing elements located in the frypot 6 Pack solid shortening into the zone below the tubes all spaces between the tubes and at least an inch above the top of the tubes before lighting the fryer I...

Страница 12: ...ased repeat the lighting procedure and keep the knob down longer Adjustment of pilot flame may be necessary 4 When the pilot stays lit turn the knob counterclockwise to the ON position Do not press down on the knob in this step 5 Do NOT turn the thermostat ON until the frypot is filled with oil or solid shortening 6 Once the frypot is filled with shortening set the thermostat to the desired temper...

Страница 13: ...he accuracy tolerance of the sensor the oil temperature may reach as high as 475 F In the event the fryer shuts down due to this condition the oil must be cooled to below 400 F before the pilot burner can be re ignited When the oil has cooled use the Lighting procedure on page 12 to place the fryer back in operation If the problem persists contact your IRON RANGE Service Representative or the IRON...

Страница 14: ...e drain and drain the frypot completely 3 Remove the basket support frame if applicable and flush out any sediment remaining in the frypot with a little hot oil 4 Wipe off the basket support frame and the inside of the frypot with a clean cloth SOME AREAS OF THE FRYPOT MAY BE HOT 5 Close drain valve and strain the oil back into the frypot through several thicknesses of cheesecloth or filter it bac...

Страница 15: ...osits that do not respond to the above procedure can usually be removed by rubbing the surface with SCOTCH BRITE scouring pads or STAINLESS scouring pads DO NOT USE ORDINARY STEEL WOOL as any particles left on the surface will rust and further spoil the appearance of the finish NEVER USE A WIRE BRUSH STEEL SCOURING PADS EXCEPT STAINLESS SCRAPER FILE OR OTHER STEEL TOOLS Surfaces that are marred co...

Страница 16: ... Number of your fryer Part Number and Description No Part Description 3 Tube 4 Tube 5 Tube 1 400045 Thermostat Knob 1 1 1 3 400044 Regulating Thermostat 200 F to 400 F 1 1 1 4 400042 Combination Gas Valve Natural 1 1 1 400146 Combination Gas Valve Propane 5 400070 Flexible Pilot Tubing 1 1 1 10 300036 Right Fryer Burner 1 1 1 300037 Center Fryer Burner 1 2 3 300038 Left Fryer Burner 1 1 1 11 40004...

Страница 17: ...NUED No Part Description 3 Tube 4 Tube 5 Tube 1 400037 Basket Support 1 1 400056 Basket Support 1 2 400036 Drain Valve Ball Style 1 1 1 3 C200016 Fry Tank Only 1 C200017 Fry Tank Only 1 C200056 Fry Tank Only 1 4 400071 Drain Extension 1 1 1 5 400075 Flue Top 1 400076 Flue Top 1 400077 Flue Top 1 6 400078 Flue Wrap 1 1 400079 Flue Warp 1 ...

Страница 18: ...e 1 300032 Door Magnet 1 1 1 3 400147 6 Adjustable Leg Opt Opt Opt 266001 1 Caster Kit 2 Front Swivel w Brake 2 Rear Fixed 1 1 1 6 400057 Fry Basket 13 25 L x 6 5 W x 6 D 2 2 400039 Fry Basket 17 5 L x 9 25 W x 6 D 2 8 400072 FLAME GUARD OPTIONAL 9 266863 2 FRYER TO FRYER CONNECTOR STRIP OPTIONAL 1 1 266863 3 FRYER TO FRYER CONNECTOR STRIP OPTIONAL 1 10 266211 1 FRY TANK COVER OPTIONAL 1 1 266211 ...

Страница 19: ...IRON RANGE FLOOR MODEL GAS FRYERS OWNER S INSTALLER MANUAL For Warranty Service Call 866 359 7378 Revision IR20191009 Page 19 THIS PAGE LEFT INTENTIONALLY BLANK ...

Страница 20: ...359 7378 A product with the IRON RANGE name incorporates the best in durability and low maintenance We all recognize however that replacement parts and occasional professional service may be necessary to extend the useful life of this unit When service is needed contact an IRON RANGE Authorized Service Provider or your equipment dealer To avoid confusion always refer to the model number serial num...

Отзывы: