5. SPECIFICATIONS.

Working frequency: 

..............................................................................................

13.56 MHz;

Supported key types: 

......................................................................

Mifare 1K, 4K, Ultralight;

Working distance: 

................................................................................................

Up to 6 cm;

Information write into key memory function: 

.............................................................

Present;

Output protocols: 

........

iButton (Dallas Touch Memory), Wiegand-26, Wiegand-34, RS-485.

Maximum connection line length:
-

 

Via iButton protocol: 

............................................................................................

up to 15 m

-

 

Via Wiegand (-26/-34) protocol: 

.......................................................................

up to 100 m;

-

 

Via RS-485 protocol: 

.....................................................................................

up to 1,200 m;

Operating mode indication: 

........................................................................

Audial and visual;

External indication control: 

.......................................................................................

Present;

Power Output: 

.....................................................................

Field-effect Transistor up to 5 A;

Power supply voltage: 

..............................................................................................

12V DC;

Maximum standby current: 

.........................................................................................

70 mA;

Case material: 

........................................................................................

Coated ABS plastic;

Dimensions, mm: 

.............................................................................................

115 x 75 x 22;

The reader has the combined inputs and outputs. The direction of an output is selected at a 
stage of configuring of the reader by the M3NConf.zip program.
Factory installations: the mode 2.1.1, the transfer protocol is selected by closing of outputs 
(Fig. 3), type of a line - on RS-485: Mifare[464B84D4] 1K(0004,08)132,19270, "No Card".

6

.  OPERATING CONDITIONS

Ambient temperature limits: 5…40°C.
Humidity: no more than 80% at 25°C.

Device specifications may differ from described in this manual when operating not under 

recommended conditions.

Device should be operated in absence of: atmospheric precipitation, direct sunlight, sand, dust 

and moisture condensation.

7

.  PACKAGE CONTENTS

Matrix

 

III 

NET

 

device

 

...........................

1

Mounting Kit  

.......................................

1

8. 

 LIMITED WARRANTY

This device is covered by a limited warranty for 

24

 months

.

The warranty becomes void if: 
- This Manual is not followed; 
- Device has physical damage; 
- Device has visible traces of exposure to moisture and aggressive chemicals; 
- Device circuits have visible traces of being tampered with by unauthorised parties.

 

Under active warranty, the Manufacturer will repair the device or replace any broken parts, 

FREE of charge, if the fault is caused by manufacturing defect. 

page 4

MATRIX

 

III NET

www.ironlogic.

me

Содержание Matrix III NET

Страница 1: ...2 1 3 The device transmits the code from protected memory sector of a Mifare key To configure 2 1 2 and 2 1 3 modes download and use free software from M3NConf zip archive at http www ironlogic me 2 2 PC Reader The Reader is connected to a PC through a converter via RS 485 protocol Mode 2 2 1 The reader reads and writes protected memory sectors of Mifare keys To work with the reader in this mode u...

Страница 2: ...p lid Note 1 Leave at least 10 cm distance between two readers If the distance is less than 30 cm their working distances can be reduced Note 2 To ensure line distance distance as specified in this manual use a UTP e g CAT5e cable When connecting via iButton the wires in twister pair should be connected to GND and D0 pins When connecting via Wiegand 26 34 two twister pairs are connected the first ...

Страница 3: ... a short beep sounds While a known key is in working zone no visual indication is present For 2 1 2 and 2 1 3 modes when an unknown key enters the working zone red LED goes momentarily OFF then back ON no sound is emitted While an unknown key is in the working zone red LED is ON External LED and sound control Comes from a controller via external control pins RED GREEN SND or RS 485 commands Turns ...

Страница 4: ...e transfer protocol is selected by closing of outputs Fig 3 type of a line on RS 485 Mifare 464B84D4 1K 0004 08 132 19270 No Card 6 OPERATING CONDITIONS Ambient temperature limits 5 40 C Humidity no more than 80 at 25 C Device specifications may differ from described in this manual when operating not under recommended conditions Device should be operated in absence of atmospheric precipitation dir...

Страница 5: ...E mail info ironlogic lv headstaff ironlogic lv Phone 37166181894 37124422922 www ironlogic me page 5 MATRIX III NET www ironlogic me The symbol of crossed throught waste bin on wheels means that the product must be disposed of at f separate collection point This also applies to the product and all accessories marked with this symbol Products labeled as such must not be disposed of with normal hou...

Отзывы: