External indication control can be used in parallel with internal indication control; by default, both
the audial and visual indications are internally controlled. After external indication control signal
has been activated for one of indication modes (for example, for the visual indication), that mode
becomes externally controlled, while the other (in this example, the audial indication) remains
under internal control.
5. PROTECTED MODE
In the Protected Mode, the reader provides reliable
protection against unauthorised access. To
initialise the Protected Mode, an IronLogic Object card containing a special key is used. This key is
stored
onto blank
access cards using a Z-2 USB MF desktop reader with special
firmware.
To store the special key to a Matrix
III MF-I reader, touch it with an IronLogic Object card. From now
on, the Matrix
III MF-I
will transmit to the controller only UIDs (serial numbers) of initialised access
cards. This reader supports holding of up to 10 IronLogic Object cards at the same time.The first
IronLogic Object card stored into the
reader becomes its Master card. It allows
storing
other
IronLogic Object cards and switching off the Protected Mode. Without this Master card, the reader
cannot be reverted to initial, Unprotected
mode.
5.1. Switching Between Protected and Unprotected Mode
From the factory, the reader arrives in Unprotected mode, transmitting to the controller the UIDs of
all
the
access
cards it could read.
5.1.1. Entering Protected Mode.
1) On an unpowered reader, connect DATA0 (white) and LED R (yellow) terminals (See Fig.1).
2) Power on the reader.
3) If the LED is blinking red and a
signal is sounding, the reader already is in Protected Mode.
4) If the LED is shining solid red, approach the reader with an IronLogic Object card. For 1 second,
the reader changes LED colour to green and issues a beep. The Object card has now been stored
into the reader
and has become a Master card.
5) Power off the reader.
5.1.2. Storing
IronLogic Object Cards (Up to 10).
1) Ensure that the reader is powered on and operational.
2) Approach it with the Master card; the LED starts blinking red. Keep approaching the reader with
more IronLogic Object Cards, with 16 s or less in between the cards. Each new card is
acknowledged with a green LED flash.
3)
To exit Storing Object Cards mode, either wait 16 s, or approach the reader again with the Master
card.
5.1.3. Leaving Protected Mode.
1)
On an unpowered reader, connect DATA1 (brown) and LED R
(yellow) terminals.
2)
Power on the reader.
3)
If the LED is blinking red and a signal is sounding, the reader already is in Unprotected mode.
4)
If
the LED is shining solid red, approach the reader with the Mastercard. For 1 second,the reader
changes LED colour to green and issues a beep. All the Object cards stored into the reader will be
erased, and the Unprotected mode will be activated.
5)
Power off the reader.
page
3
MATRIX III MF-I
www.ironlogic.
me