4. SPECIFICATIONS

- Working

 

frequency:  ...................................................................125 kHz;

- Used token types: ......................................EM-Marine, HID

 ProxCard II

;

- Reading distance:  ...................................................................

2

…10 cm;

- Output interface:  ..............Wiegand-26, iButton (Dallas Touch Memory);
- Line distance via iButton protocol: .........................................up to 15 m;
- Line distance via Wiegand-26 protocol:  ..............................up to 100 m;
- Power supply voltage: ...............................................................12 V DC;
- Power supply current:  .........................................................max. 35 mA;
- Status indication:  .........................................visual  LED, audial  buzzer;
- External status indication control:  ..........for audial and visual indication;
- Case material: ......................................................................ABS plastic;
- Dimensions:  ..............................................................120 

×

 45 

×

 22 mm.

Figure 1.

 Choosing the transmission protocol

.

Figure 2.

 Device Dimensions

.

DATA1

GND

D

0

DATA0

D1

GND

D

0

iButton

D1

GND

D

0

iButton

D1

IButton (One-time transmission)

Wiegand

IButton (DS1990A emulation)

ACS  controller

Reader

GND

GND

GND

screw

1

20 

mm

82 mm

45

 mm

Wire Colour

 

Wire Designation

 

Red 

+12V 

Black 

Common (-) 

White 

DATA0 

Brown 

DATA1 

Green 

External control for the green LED 

Yellow 

External control for the red LED 

Blue 

External control for the buzzer 

 

Table 1. 

Controller connections.

MATRIX III EH

www.ironlogic.

me

page 

2

22 

mm

Содержание Matrix III EH

Страница 1: ... one mode can be used with internal indication control for another if for instance external indication signal for LEDs is activated the LEDs get under external control while the buzzer remains under internal control 3 MOUNTING AND CONNECTION To mount the reader perform the following sequence Mark and drill the mounting holes per Fig 2 Connect the reader wires according to Table 1 Insulate all wire...

Страница 2: ... for audial and visual indication Case material ABS plastic Dimensions 120 45 22 mm Figure 1 Choosing the transmission protocol Figure 2 Device Dimensions DATA1 GND D0 DATA0 D1 GND D0 iButton D1 GND D0 iButton D1 IButton One time transmission Wiegand IButton DS1990A emulation ACS controller Reader GND GND GND screw 120 mm 82 mm 45 mm Wire Colour Wire Designation Red 12V Black Common White DATA0 Br...

Страница 3: ...warranty for 24 months The warranty becomes void if this Manual s guidelines are not followed the device has suffered physical damage the device has visible traces of exposure to moist and or aggressive chemicals the device circuits have visible traces of tampering by unauthorised parties Under this warranty the Manufacturer shall repair the device or replace any broken parts as required free of c...

Страница 4: ... E mail info ironlogic lv headstaff ironlogic lv Phone 37166181894 37124422922 www ironlogic me The symbol of crossed throught waste bin on wheels means that the product must be disposed of at f separate collection point This also applies to the product and all accessories marked with this symbol Products labeled as such must not be disposed of with normal household waste but should be taken to a ...

Отзывы: