background image

   
1.  OVERVIEW

Matrix

 

III 220 Reader is a power relay controlled by contactless cards. The device is a combo 

EM-Marine contactless cards reader, and controller with 

memory up to 500 cards

.

The device has a waterproof casing with 2 outgoing cables: 2-wire power supply cable (220 V, 
35 mA) and a 3-wire power relay control cable (250 V, 6 A). Also supplied with the device is an 
interchangeable pocket accessory that can be attached to the device, to secure the card in 
reader working zone. 

The device can be used to control 

power

 supply in hotel rooms, hostels and dormitories, 

outbuildings, business premises, in events planning and property maintenance and decoration 
works etc.

Master cards are used to program the device.

Access cards are used to operate the device.
A card becomes a Master card or an Access card during its programming.

  2.  SPECIFICATIONS

Supply voltage: .............................................................................. 220 V
Consumption current:  ...................................................................35 mA
Power relay circuit current: 

.........................................................

max 6 A

Power relay circuit voltage: 

.....................................................

max 250 V

Reader working frequency:  ........................................................125 kHz
Cards standard:  .....................................................................EM-Marine
Reader working distance: 

.................................................................

6 cm

Maximum cards number: ...................................................................500
Operation mode indication: 

...........................................

Audial and visua

l

Casing material:  ....................................................................ABS plastic
Dimensions, mm: 

.................................................................

115 x 75 x 27

Device dimensions with the pocket accessory clipped on are illustrated in the Fig.: 

page 

1

MATRIX

 

III 220

www.ironlogic.

me

1

1

5

75

2

7

22

Matrix

 

III 220

Standalone power saving controller 

with built-in EM-Marine reader and 500 keys memory 

 

User Manual

 

Содержание Matrix III 220

Страница 1: ...ing and property maintenance and decoration works etc Master cards are used to program the device Access cards are used to operate the device A card becomes a Master card or an Access card during its programming 2 SPECIFICATIONS Supply voltage 220 V Consumption current 35 mA Power relay circuit current max 6A Power relay circuit voltage max 250 V Reader working frequency 125 kHz Cards standard EM ...

Страница 2: ...er the contacts are closed no longer than the Release Interval programmed with a Master card Device has 3 programming modes Add Access card Erase All Cards and Release Interval Setup 4 CABLES PURPOSE Power Supply Cable 2 wires Power Relay Control Cable 3 wires page 2 Wire Colour Purpose 1 Brown 220 V AC 2 Blue 220 V AC Wire Colour Purpose 1 Brown NC Norm ally Closed 2 Black Mix COM Com mon 3 Blue ...

Страница 3: ...ges into blinking yellow indicating Release Timer Setup Mode In further 5 s the blinking stops and the device returns to its normal operation the LED will become solid and its colour will indicate one of the three Operation Modes selected in paragraph 6 1 Holding the Master card further will repeat the cycle through the programming modes described above Blinking green Blinking red Blinking yellow ...

Страница 4: ...Pocket mode the contacts state always corresponds to one described in paragraph 4 To go forward with the erase touch and hold the Master card the LED will slowly blink red then will flash green once to acknowledge that all cards including the Master card have been erased After that the device will revert into normal operation and indicate its current operation mode by solid indication of one of th...

Страница 5: ...ric precipitation direct sunlight sand dust and moisture condensation 10 LIMITED WARRANTY This device is covered by a limited warranty for 24 months The warranty becomes void if This Manual is not followed Device has physical damage Device has visible traces of exposure to moisture and aggressive chemicals Device circuits have visible traces of being tampered with by unauthorised parties Under act...

Страница 6: ... E mail info ironlogic lv headstaff ironlogic lv Phone 37166181894 37124422922 www ironlogic me page 6 MATRIX III 220 www ironlogic me The symbol of crossed throught waste bin on wheels means that the product must be disposed of at f separate collection point This also applies to the product and all accessories marked with this symbol Products labeled as such must not be disposed of with normal ho...

Отзывы: