background image

200 Range Dialer
Installation Manual

Version 1.0

Содержание Touch 200

Страница 1: ...200 Range Dialer Installation Manual Version 1 0 ...

Страница 2: ...errors or omissions No part may be reproduced or used except as authorised by contract or other written permission The copyright and foregoing restriction on reproduction and use extend to all media in which the information may be embedded 2008 Chiron Technology Ltd ...

Страница 3: ......

Страница 4: ...3 2 1 Package contents 3 2 2 Pre requisites 3 3 Alarm dialer interface 4 4 Installing the IRIS Touch Dialer 4 5 Configuring the IRIS Touch Dialer 7 6 Post installation 8 7 PIN alarms 8 7 1 Installation 9 7 2 Default alarm messages 10 8 Relay outputs 10 9 Troubleshooting 10 Appendix A Settings menu 11 Appendix B Installation photos 12 Appendix C Specification 14 ...

Страница 5: ...Iris Touch 200 Range Dialer Installation Manual ii ...

Страница 6: ...g increasingly unsuitable as users move to IP and Voice over IP VoIP for their fixed networks or rely purely on mobile GSM and GPRS communications In addition most PSTN service providers are migrating to VoIP networks so in the not too distant future PSTN lines may be withdrawn The IRIS dialer range is unique in offering a quick and cost effective way to interface any existing alarm system to alte...

Страница 7: ...tact ID Scancom Fast Format and Robofon protocols Pin inputs for alarm messages over SMS 4 4 4 Relay contact outputs 2 2 2 9 30V DC power from alarm panel USB port for local configuration Secure polling monitoring over Ethernet Secure alarm transmission over Ethernet Pin inputs for alarm messages over Ethernet or GPRS 4 4 Configuration and diagnostics over Ethernet Secure polling monitoring over G...

Страница 8: ...or installations using IP Ethernet or GPRS you must ensure you have the following The IP address for the Monitoring Centre Confirmation that the Monitoring Centre is set up and ready for the account number or name to be used for this IRIS dialer The type of IP address either automatic or fixed for the installation site If the site has a fixed IP address you should get this information from the cus...

Страница 9: ...our IP address numbers separated by a should be entered as a 3 digit number with leading 0 s as required and the s should be excluded For example IP address 10 1 146 22 is entered as 010001146022 If the Monitoring Centre requires a backup IP address to be entered this is done in the same way 2 If alarm signalling over GSM is required add a leading digit 7 to the normal PSTN telephone number of the...

Страница 10: ...lied 6 4 Plug in the connectors Connect the relevant cables to the PCB Ethernet cable cream 7 Ethernet Ethernet GPRS only Dialer cable grey 8 Power cable black 9 5 Install the antenna GSM Ethernet only Position the antenna in the groove in the back plate of the unit 10 and connect the antenna to the PCB 11 Note Alternatively you can use an external antenna if the location of the internal antenna d...

Страница 11: ...nnector off the cable and strip the cable using the 2 inner wires Polarity is not important Plug the Ethernet cable into the local IP router or socket that has been allocated for the IP connection 10 Plug in the sense resistors Fit the 18K sense resistor in parallel with the dialer output of the alarm panel at the alarm panel end of the cable Note This resistor enables the IRIS dialer to detect ca...

Страница 12: ...ing procedure to configure the IRIS Touch Dialer 1 Plug the power cable into the battery backed supply of the alarm panel The cable with the white stripe is the ve connection Ensure that the display on the dialer becomes active The dialer carries out a self test and the Welcome screen then displays Note If the power has been connected for the first time the Language menu displays Select the approp...

Страница 13: ...t flashing and the display will show a system fault message This message can be touched to gain access to more information Ensure the user is aware of this and what action they need to take should a fault occur 7 PIN alarms The IRIS Touch series have PIN inputs 18 that can be used to generate alarm messages These can be Text messages via SMS GSM Ethernet GPRS only SIA alarm messages over IP to the...

Страница 14: ...ntact i e loop is open circuit generates an alarm signal Closing the contact generates the equivalent restore signal It is also possible to link the contacts to the IRIS dialer via sense resistors so that an open or short circuit tamper on the loop can be detected and the Monitoring Centre alerted In this case the connections should be made as shown below Note For this feature to work correctly it...

Страница 15: ...tting by the Monitoring Centre The relay contacts are normally open and closed when activated Wire to these contacts as required and define how they are to be used using the configuration options on the Settings Menu See Appendix A for more details 9 Troubleshooting Problem Resolution No screen display when IRIS dialer is connected to the power Check that there is power to the system and that the ...

Страница 16: ...uts Selects whether or not pin input is monitored using sense resistors and selects input function Send SMS message Send SIA format alarm over IP trouble and restore event codes and zone number Send Fast Format alarm over IP alarm or open close and set pin polarity Relay Outputs Activation of relay outputs by incoming SMS messages Trouble Reporting Selects how local communications problems are rep...

Страница 17: ...Iris Touch 200 Range Dialer Installation Manual 12 Appendix B Installation photos 1 2 3 5 4 6 ...

Страница 18: ...Iris Touch 200 Range Dialer Installation Manual 13 9 7 8 13 14 17 16 18 11 10 12 15 20 19 ...

Страница 19: ...rms UDP ports for upload download 8738 and 8739 PIN Inputs Maximum input voltage range 0V to 24V Input low threshold 2V Input high threshold 3V Input pull up impedance Internal 10K to 5V supply Relay Outputs Maximum operating voltage 24V Maximum current rating 1A Power Supply Supply voltage 9 30V DC Ethernet only typical current dialer on hook 145mA supply at 12v Ethernet only typical current dial...

Страница 20: ...s are compliant to ATS 6 compatible with Security Grade 4 Safety Care should be taken when interconnecting telecommunications equipment that only like interfaces are interconnected to avoid safety hazards SELV SELV Safety Extra Low Voltage is defined as a secondary circuit which is so designed and protected that under normal and single fault conditions the voltage between any two accessible parts ...