About the configuration 

The setup is on delivery a standard setup made for a quick start and a basic system setup. 

The inputs are set to work as digital inputs.

The radio channel is set to channel 1 (433.075 MHz) and the IRIS-IO is set to send and receive broadcast messages. 

Every change on an input will generate a broadcast message that will change the corresponding output on the IRIS-IO that 

are listening. For an IRIS-IO to react it must be set to the same radio channel and set to receive broadcast messages.

No other functions are implemented in this setup but all settings can be changed using the IRIS-Configuration tool (see the 

CD for installation files).

Using IRIS-IO for other applications

The IRIS products are made for monitoring and controlling external system. The standard setup is of course not suitable 

for all applications so feel free to change the settings according to the current application. The original configuration file is 

available on the CD.

Examples on what can be done: 

· The inputs can individually be set to work as either digital or analogue inputs. 

· High and low for digital inputs can be set to match the input signals. 

· Analogue inputs have two different limits that can be detected and the value of the signal can be read.  The value can be 

scaled so that the value corresponds with for example a temperature from a sensor.  

· The radio channel can be changed if there is interference from other equipment. All IRIS units must be set to the same 

channel to be able to communicate with each other. 

· The destination of a message can be changed. A message can be broadcasted or sent with an address. If a message is 

broadcasted all IRIS units on the same channel that are set to receive broadcast messages will receive it and will be able 

to take proper actions. Only the intended IRIS unit will receive an addressed message and a receipt will be sent to the 

transmitter to verify that the message was delivered. 

· The IRIS can detect predefined texts in messages, via both the serial interface and the radio, and take different actions 

depending on the text. 

· Timers, counters and flags can be used to make a more flexible setup. 

· Radio networks can contain several nodes where the IRIS units communicate with each other via other IRIS modules that 

are in between.

For more information about the configuration possibilities and how to setup the IRIS-RS232 see the IRIS-Configuration 

manual.

������

PC

IRIS-IO

Machine

IRIS-IO

IRIS-IO

IRIS-IO

Temperature

Temperature

Temperature

Voltage

Voltage

�����

�����

�����

Lights

�����

�����

�����

������

������

IRIS-RS232

Содержание IRIS-IO

Страница 1: ...RIS IO so that the antenna is not shielded Avoid metal plating close to and between the antennas IRIS IO Product description IRIS IO can be used with different kind of electrical equipment for example relays switches sensors LED and machines with digital and analogue outputs and digital inputs The most common use of IRIS IO is a pair of IRIS IO that relays digital signals between two systems This ...

Страница 2: ...alogue inputs have two different limits that can be detected and the value of the signal can be read The value can be scaled so that the value corresponds with for example a temperature from a sensor The radio channel can be changed if there is interference from other equipment All IRIS units must be set to the same channel to be able to communicate with each other The destination of a message can...

Страница 3: ...the expected event Check that the event works and that it is connected to the right action The easiest way to check that the event works is to trigger another action For example set an output high and check the LED on the side of the IRIS IO It is always possible to change the configuration back to the original configuration using the IRIS configuration tool The original configuration file is found on ...

Страница 4: ... 33 E Mail info trlfunk de Internet www trlfunk de Technical data Radio communication Frequency 433 050 434 775 MHz 439 700 439 975 MHz Channel pattern 25 kHz channel spacing 70 channels from 433 050 to 434 775 MHz 12 channels from 439 700 to 439 975 MHz for the Swedish market Sensitivity 112 dBm 50 ohm Modulation type FSK Bit rate 4800 bit s Range 1 km in line of sight I O Digital analogue inputs...

Отзывы: