Unit Number: P 7 - M 7 P 3 8 3 - E 7 A A B B
Note: Specifications and Dimensions subject to change without notice.
Visit our web site at www.cooperlighting.com
Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770 486.4801 ADI030704
Cooper Lighting 5925 McLaughlin Rd. Mississauga, Ontario, Canada L5R 1B8 905.507.4000 FAX 905.568.7049
Notes and Definitions:
Luminance: To convert cd/m
2
to footlamberts, multiply by 0.2919
• Beam spread is to 50% center beam candlepower (CBCP.)
• Data shown is based on bare lamp photometrics.
D=Distance to floor or wall.
FC=Footcandles on floor or wall at center beam aiming location.
L =Effective Visual Beam length in feet (50% of maximum footcandle level.)
W=Effective Visual Beam width in feet (50% of maximum footcandle level.)
CB=Distance across or down to center beam location.
0 ° A i m i n g A n g l e
3 0 ° A i m i n g A n g l e
3 0 ° A i m i n g A n g l e
L a m p
H o r i z o n t a l F o o t c a n d l e s
H o r i z o n t a l F o o t c a n d l e s
Ve r t i c a l F o o t c a n d l e s
P H O T O M E T R I C S
90 PAR/CAP/SPL/3WSP12
12° x 12°
CBCP: 14,300
D
FC
L
W
7'
292
1.9
1.9
10'
143
2.5
2.5
13'
85
3.1
3.1
16'
56
3.8
3.8
D
FC
L
W
CB
6'
298
2.1
1.9
3.5
8'
168
2.
2.3
4.6
10'
107
3.2
2.8
5.8
12'
74
3.8
3.3
6.9
D
FC
L
W
CB
4'
223
3.9
2.1
6.9
5'
143
4.7
2.5
8.7
6'
99
5.6
2.9
10.4
7'
73
6.5
3.3
12.1
90 PAR/CAP/SPL/3FL30
30° x 30°
CBCP: 3,500
D
FC
L
W
4'
219
2.5
2.5
5'
140
3.1
3.1
6'
97
3.6
3.6
7'
71
4.1
4.1
D
FC
L
W
CB
3'
292
2.6
2.3
1.7
4'
164
3.3
2.9
2.3
5'
105
4.1
3.5
2.9
6'
73
4.8
4.1
3.5
D
FC
L
W
CB
2'
219
5.9
2.5
3.5
3'
97
8.6
3.6
5.2
4'
55 11.3
4.7
6.9
5'
35 14.1
5.8
8.7