IRIS 216 Скачать руководство пользователя страница 12

8.01 Protocol Command List

The  table  below  lists features specific to IRIS216/316 Thermal  Cameras that are not covered  by the standard Pelco-D  protocol  and the 
commands  that  have  been  mapped  in  IRIS  camera  software  to  operate  those  features.  Values  are  shown  in  hexadecimal.  The 
checksum  for  all  Pelco-D  commands is the 8 bit (modulo  256) sum  of the payload  bytes (bytes 2  ~  6)  within  the message.  Refer  to  the 
Pelco-D protocol document for further information.

Function

Value

Command

H

Add

C1

C2

D1

D2

CHK

Video Standard

PAL

Preset xx

FF

AD

00

07

00

C7

CHK

NTSC

Preset xx

FF

AD

00

07

00

C8

CHK

Video Orientation

Desktop Standard

Preset 236

FF

AD

00

07

00

EC

CHK

Hanging Standard

Preset 237

FF

AD

00

07

00

ED

CHK

Desktop Mirror

Preset 238

FF

AD

00

07

00

EE

CHK

Hanging Mirror

Preset 239

FF

AD

00

07

00

EF

CHK

Set New Home Position

Set Home

Set Home

FF

AD

00

49

00

00

CHK

Call Home Position

Call Home

Preset 230

FF

AD

00

07

00

E6

CHK

Thermal Colour Palettes

Mono / White Hot

Preset 201

FF

AD

00

07

00

C9

CHK

Mono / Black Hot

Preset 202

FF

AD

00

07

00

CA

CHK

Redscale / Red Hot

Preset 203

FF

AD

00

07

00

CB

CHK

Redscale / Black Hot

Preset 204

FF

AD

00

07

00

CC

CHK

Ironbow

Preset 205

FF

AD

00

07

00

CD

CHK

Reverse Ironbow

Preset 206

FF

AD

00

07

00

CE

CHK

Greenscale / Green Hot

Preset 207

FF

AD

00

07

00

CF

CHK

Greenscale / Black Hot

Preset 208

FF

AD

00

07

00

D0

CHK

Rainbow

Preset 209

FF

AD

00

07

00

D1

CHK

Reverse Rainbow

Preset 210

FF

AD

00

07

00

D2

CHK

Hot Metal

Preset 211

FF

AD

00

07

00

D3

CHK

Reverse Hot Metal

Preset 212

FF

AD

00

07

00

D4

CHK

Isotherm

Preset 213

FF

AD

00

07

00

D5

CHK

Reverse Isotherm

Preset 214

FF

AD

00

07

00

D6

CHK

High Contrast

Preset 215

FF

AD

00

07

00

D7

CHK

Reverse High Contrast

Preset 216

FF

AD

00

07

00

D8

CHK

Bluescale / Blue Hot

Preset 217

FF

AD

00

07

00

D9

CHK

Bluescale / Black Hot

Preset 218

FF

AD

00

07

00

DA

CHK

Non Uniformity Correction (NUC)

NUC

Preset 240

FF

AD

00

07

00

F0

CHK

45˚ Auto Scan

Slow

Scan 45 Slow

FF

AD

00

39

04

01

CHK

Medium

Scan 45 Med

FF

AD

00

39

04

01

CHK

Fast

Scan 45 Fast

FF

AD

00

39

04

01

CHK

Содержание 216

Страница 1: ...216 316 USER GUIDE ...

Страница 2: ...TEM EXAMPLES 6 4 01 CAMERA CONTROL DATA 6 4 02 CABLING REQUIREMENTS 6 4 03 SETTING CAMERA ADDRESS 6 4 04 INSTALLATION CONSIDERATIONS 6 4 05 PROTOCOL INFORMATION 7 5 01 HARDWARE INSTALLATION 9 6 01 CONNECTIONS 9 6 02 VIDEO CONNECTIONS 9 6 03 DATA CONNECTIONS 9 6 04 POWERING UP 10 7 01 CONTROLLING THE CAMERA 12 8 01 PROTOCOL LIST 14 9 01 CAMERA ADDRESS TABLE 15 10 01 SPECIFICATIONS 16 BACK COVER CON...

Страница 3: ...ositional Indicator 360 Variable Speed Continuous Rotation 210 Variable Speed Tilt Mode Auto Flip Feature to Automatically Correct the Camera Orientation when the Tilt Passes itʼs Tilt Azimuth Video Freeze Feature User Programmable Pattern Tours IRIS216 Model features 44 Greater Resolution then Standard QVGA Cameras IRIS316 features 17µm Pixel Pitch for Superior Picture Clarity Thermal Sensitivity...

Страница 4: ...se this product CAUTION Service and Maintenance This product contains no user serviceable parts Please refer all maintenance and repair issues to your authorized Iris Innovations dealer Any unauthoriZed work to the product may affect the warranty CAUTION Care and Cleaning This product is a sensitive piece of electronic imaging equipment and must be handled and treated accordingly Do not drop or sh...

Страница 5: ...s offered by most chart plotters and so a video switcher such as the IRIS606 c Camera switcher would be required Video from each camera is routed into the video switcher and the output from the switcher is then routed into a single input of the chart plotter Switching is controlled by a dedicated waterproof keypad connected to the switcher The data wires from each of the controllable cameras along...

Страница 6: ... Cables need to be twisted pair Belden style data cables 0 5mm or equivalent 4 03 Setting Camera Address Each camera must have itʼs own unique address so that only control data intended for that camera is received and processed by the camera If multiple cameras had the same address they would all move together when pan and tilt commands are transmitted To set the camera address remove the DIP swit...

Страница 7: ...To avoid moisture ingress between the bottom of the BRK P160 fixing plate and the surface onto which the camera is to be attached apply a bead of suitable silicone sealant around the edge of the plate to create a seal Fixing Plate IRIS BRK P160 For mounting onto flat surfaces either standard or hanging orientation Camera Fixing Points 3 x Counter sunk fixing holes for attaching camera to fixing pl...

Страница 8: ...g Plate to base of camera M5 x 10mm Countersunk Screws Supplied in 3 positions Fix Mounting Plate to base of camera Cable Entry Route umbilical cable through here Standard or ʻDesktopʼ Orientation The camera is factory set for installation in the ʻStandardʼ orientation as shown here To install in the hanging orientation as shown in the main image above ensure the cameras video output has been set ...

Страница 9: ...ect the RS485 wires to a power source as this could permanently damage the camera or controller Observe care when connecting as the RS485 wires are coloured red and black and could be confused for DC power lines Even if the cable connections are made in an internal location or in an area that wouldnʼt usually be exposed to moisture it is recommended that the connections are protected from any poss...

Страница 10: ...n the slower it will pan and tilt when commanded and vice versa This greatly improves control accuracy when zoomed in Auto Flip When the camera is tilted past its azimuth the Auto Flip feature is triggered This automatically pans the camera through 180 at full speed Proportional Control is disabled during this procedure to the original pan position and continues the tilt movement as long as the ca...

Страница 11: ...ent Scan Modes The camera supports 4 different Scan Modes Once activated tilt and zoom commands are still accepted by the camera but you will not be able to pan the camera until the Scan has been Stopped 45 Auto Scan Camera pans back and forth 22 5 either side of the centre point the position the camera is facing when the scan is activated 90 Auto Scan Camera pans back and forth 45 either side of ...

Страница 12: ... 00 E6 CHK Thermal Colour Palettes Mono White Hot Preset 201 FF AD 00 07 00 C9 CHK Mono Black Hot Preset 202 FF AD 00 07 00 CA CHK Redscale Red Hot Preset 203 FF AD 00 07 00 CB CHK Redscale Black Hot Preset 204 FF AD 00 07 00 CC CHK Ironbow Preset 205 FF AD 00 07 00 CD CHK Reverse Ironbow Preset 206 FF AD 00 07 00 CE CHK Greenscale Green Hot Preset 207 FF AD 00 07 00 CF CHK Greenscale Black Hot Pr...

Страница 13: ...FF AD 00 07 00 61 CHK Set Camera Safe Position Set Safe Set Preset 232 FF AD 00 03 00 E8 CHK Call Camera Safe Position Call Safe Preset 232 FF AD 00 07 00 E8 CHK Freeze Image Freeze Preset 234 FF AD 00 07 00 EA CHK Un Freeze Image Resume Preset 235 FF AD 00 07 00 EB CHK Scene Mode Off Preset 220 FF AD 00 07 00 DC CHK Day Preset 221 FF AD 00 07 00 DD CHK Night Preset 222 FF AD 00 07 00 DE CHK Fog P...

Страница 14: ...F ON OFF OFF OFF OFF 11 ON ON OFF ON OFF OFF OFF OFF 12 OFF OFF ON ON OFF OFF OFF OFF 13 ON OFF ON ON OFF OFF OFF OFF 14 OFF ON ON ON OFF OFF OFF OFF 15 ON ON ON ON OFF OFF OFF OFF 16 OFF OFF OFF OFF ON OFF OFF OFF 17 ON OFF OFF OFF ON OFF OFF OFF 18 OFF ON OFF OFF ON OFF OFF OFF 19 ON ON OFF OFF ON OFF OFF OFF 20 OFF OFF ON OFF ON OFF OFF OFF 21 ON OFF ON OFF ON OFF OFF OFF 22 OFF ON ON OFF ON OF...

Страница 15: ...OB mode applies box around hottest object in scene MOB mode applies box around hottest object in scene MOB mode applies box around hottest object in scene MOB mode applies box around hottest object in scene Video Pause Yes Yes Yes Yes Standby Mode Yes Yes Yes Yes Communications Protocol Serial Control RS485 Pelco D Protocol Iris Variant Serial Control RS485 Pelco D Protocol Iris Variant Serial Con...

Страница 16: ...wick Hampshire SO31 7GB United Kingdom Tel 44 0 1489 570797 email info boat cameras com web www boat cameras com Iris Innovations Limited USA Suite 130 401 E Las Olas Blvd Fort Lauderdale 33301 Flordida United States of America email info boat cameras com web www boat cameras com ...

Отзывы: