4.5 Connector Sealing in Harsh Environments

If the 9522A is to be used in a harsh environment with exposure to high
humidity or water, the mating of the multi-interface connector must be
further sealed to protect from moisture entry. It is recommended that a
bead of RTV silicone sealant be placed on the connector mating to the
9522A’s multi-interface connector where shown in Figure 6 below. A
material similar to Permatex 16B should be used.

Figure 6:

Place a bead of Silicone RTV material along this area all

around the connector mating to the 9522A’s multi-interface connector.

5 Environmental

The environmental specifications of the 9522A are summarized in Table
3 below.

Table 3: Environmental Specifications

6 Electrical Interfaces

The subsections to follow contain interface information for the electrical
interfaces of the 9522A.

6.1 DC Power Interface

6.1.1 DC Power Interface Signal Descriptions

The DC power interface is comprised of the DC power inputs and a
control signal as summarized in Table 4 below. The EXT_PWR and
GND inputs are used to supply DC power to the 9522A. The
EXT_ON_OFF control input is pulled to a GND level to toggle the 9522A
on and off. Note that both pairs of pins should be connected for EXT
PWR and EXT GND.

Table 4: Control/Audio Interface Signal Descriptions

Signal Name

Signal Description

EXT_PWR (pin 4 and 16)

External power +4.4VDC input

EXT_GND (pin 3 and 17)

External power GND input

EXT_ON_OFF (pin 1)

Power on/off control input

Parameter

Value

Operating Temperature Range

-20°C to + 60°C

Operating Humidity Range

75% RH

Storage Temperature Range

-40°C to + 85°C

Storage Humidity Range

93% R

62425_user_guide  3/23/06  1:55 PM  Page 5

Содержание 9522A

Страница 1: ...9522A L BAND TRANSCEIVER USER S GUIDE 62425_user_guide 3 23 06 1 55 PM Page 1...

Страница 2: ...tenna Connector 4 4 3 3 SIM Chip Reader 4 4 4 Mounting 4 4 5 Connector Sealing in Harsh Environments 5 5 Environmental 5 6 Electrical Interfaces 5 6 1 DC Power Interface 5 6 1 1 DC Power Interface Sig...

Страница 3: ...7 7 2 Instructions from the integrator to the user 8 8 Modem Commands and Configuration 8 Iridium Limited Warranty for Satellite Subscriber Radiotelephone Products 9 Coverage and Duration 9 Conditions...

Страница 4: ...Analog Audio Control Digital Audio RS232 Power Input On Off 2 Export Compliance Information This product is controlled by the export laws and regulations of the United States of America The U S Govern...

Страница 5: ...d in Table 1 below Table 1 Mechanical Dimensions 4 2 Dimensional Views Dimensioned views of the 9522A are shown in Figures 2 5 to follow Figure 2 Side View Parameter Value Length including antenna con...

Страница 6: ...M Chip Connector located beneath a cover plate atop the 9522A 4 3 1 Multi Interface Connector The multi interface connector is a 25 pin D subminiature type that includes four interfaces DC Power Contr...

Страница 7: ...6 32 thread type option is to insert a helical coil insert with a 6 32 internal thread into these features thus accommodating 6 32 threaded fasteners as mounting hardware for the 9522A National Aerosp...

Страница 8: ...erfaces The subsections to follow contain interface information for the electrical interfaces of the 9522A 6 1 DC Power Interface 6 1 1 DC Power Interface Signal Descriptions The DC power interface is...

Страница 9: ...ation 6 3 2 Autobaud The 9522A default is for autobaud to be enabled Autobaud will occur on the following characters a A CR carriage return Autobaud will also occur on the escape sequence character pr...

Страница 10: ...with operating instructions and any other information relating to the maintenance and safety of the equipment sub section 7 2 7 1 Instructions for the Integrator The 9522A must be installed by an appr...

Страница 11: ...the integrator to the user To comply with the requirements of sub clause 1 7 2 Safety instruc tions of the European Information technology equipment safety standard EN60950 1 2002 the integrator must...

Страница 12: ...ide of the U S A any different warranty terms liabilities and or legal requirements of the country in which the Product is sold are specifically disclaimed by Iridium 2 Conditions Not Covered By This...

Страница 13: ...ser s name address and telephone number and a written description of the problem Product that is repaired or replaced under this warranty shall be returned to Purchaser at Iridium s expense for the fr...

Страница 14: ...ng when available the geographic coordinates of equipment to governmental and quasi governmental agencies where Iridium deems it necessary in its sole discretion to respond to an exigent circumstance...

Страница 15: ...12 E C Directive Declaration of Conformity 62425_user_guide 3 23 06 1 55 PM Page 12...

Страница 16: ...SA Phone 1 301 571 6200 Fax 1 301 571 6250 Iridium Satellite LLC 8440 S River Parkway Tempe AZ 85284 Toll Free from a landline 1 866 947 4348 Local or International 1 480 752 5155 Fax 1 480 752 1105 e...

Отзывы: