Cleaning and Maintenance  

 

      The device does not require any special maintenance.

      Remove the battery before cleaning the device.

      Never use aggressive cleaning products or stiff brushes.

      Device may be cleaned with slightly moistened cloth while ensuring that water 

      does pentrate device. Do not immerse. Do not use the device again until it is   

      completely dry.

      Remove the battery from the device if it is not going to be used for some time. 

      Do not expose the device to direct sunlight and protect it against dirt and moisture.

      With the electrode pad on the protective plastic film, store the device in a 

      cool, dry place.

Electrode Pads

      For single person use only.

      Clean the adhesive surface after use to achieve better adhesion. 

      Moisten the gel with a drop of water and allow it to dry briefly. 

      Then stick the electrode back on the protective film.

      The length of time the electrodes remain usable depends on their storage, 

      skin type, and use. Store the electrode in a cool, dry place. 

11

     o    Replace electrode when it is no longer tacky or show 
           cracks/blemishes are visible
     o    The electrode is good for 20~30 times of use, 20 min each time.

      Be sure to use only iReliev® Patch Pads Refill Kit (ET-1414)

      or Electrode Pads (ET-0404).

     Self-adhesive Electrode Pads

     iReliev® Patch Pads Refill Kit   

     measured by length and width of  

     electrode size

Size 72 x 57mm, snap type

   Contact iReliev® for ordering information and replacement part(s),

        at www.iReliev.com.

Содержание ET-0303

Страница 1: ...WiTENS Mini Pain Relief Patch TENS Therapy Instruction Manual...

Страница 2: ...n to WiTENS Mini Pain Relief Patch 7 Components and Functional Parts of the Unit Prior to Use Installing Changing the Battery Use and Functions After Use Cleaning and Maintenance 11 Device Electrode P...

Страница 3: ...e this device if any of the following conditions are present If you have a cardiac pacemaker implanted defibrillators or any other implanted metallic or electronic device If you have undiagnosed chron...

Страница 4: ...not use the Pain Relief Patch over or close to sores Do not use this device while sleeping Do not use if you feel numbness Do not use these devices in or close to water Use the Pain Relief Patch only...

Страница 5: ...ealth problem You should know the reason and source of your pain before using this device Do not solely rely on the treatment of this device for pain The safety of using the Pain Relief Patch during p...

Страница 6: ...reaction It is not considered a skin irritation and it will normally disappear within 30 minutes after the electrodes are removed If the redness does not disappear after 30 minutes from the removal of...

Страница 7: ...mal household and work activities Components and Functional Parts of the Unit On Intensity Up Switch Function Display LED Green Back Side Battery Compartment Off Intensity Down Switch Electrode Pad Ad...

Страница 8: ...ce the electrode pad with the contact plugs up onto a flat surface Place the WiTENS Mini Pain Relief Patch with the contact jacks down onto the electrode pad so that plugs and jacks are aligned Then p...

Страница 9: ...tton again the device starts to work at the lowest level of intensity The device has 10 levels of intensity for strength of treatment Select these intensity levels by simply pressing ON UP button the...

Страница 10: ...by taking the electrode pad at the edge and pulling carefully Do not grasp at the unit Replace the electrode pad onto the clear plastic shield 3 Never remove the unit when it is switched on 4 Notes fo...

Страница 11: ...Electrode Pads For single person use only Clean the adhesive surface after use to achieve better adhesion Moisten the gel with a drop of water and allow it to dry briefly Then stick the electrode back...

Страница 12: ...Placement of Electrode 12...

Страница 13: ...kin Replace battery Check electrode pads and replace if necessary Replace battery Check electrode pads and replace if necessary Re apply the electrode pad and the device to the skin CAUSE No battery i...

Страница 14: ...om 0 60mA 20 Pulse Width 150 250uS Pulse Rate 30 60Hz Power Source 1 Lithium Coin Cell battery CR2032 Automatic Shut Off 20 minutes Operating Conditions 50 F 10 C to 104 40 C 40 90 max Relative humidi...

Страница 15: ...other accessories are guaranteed to be free from defects in workmanship and materials at the time of delivery The warranty does not apply to damage resulting from failure to follow the operating inst...

Страница 16: ...whatsoever regarding your WiTENS Mini Pain Relief Patch Model ET 0303 contact your reseller or ExcelHealth Inc at 855 723 2582 or visit www iReliev com ExcelHealth Inc www iReliev com 5825 Park Vista...

Отзывы: