![IR Energy EvenTube ETS Скачать руководство пользователя страница 38](http://html1.mh-extra.com/html/ir-energy/eventube-ets/eventube-ets_installation-operation-and-service-instructions_2089960038.webp)
S
ERIES
E
VEN
-T
UBE
38
10-03-2017
Maintenance & Trouble Shooting
Trouble shooting continued…
Burner Does Not Light
Is spark visible through site glass during ignition trial? If no, further electrical checks by a
qualified service person are required.
Check to see if gas lines were properly purged of air.
Check inlet and outlet gas pressure during ignition period.
Check for proper orifice and air plate.
Burner Does Not Stay Lit
Check ground wire continuity.
Check insulation on the igniter leads.
Measure flame signal current; it should be between 2 to 6 micro amps dc. Minimum 0.8
micro amps.
Clean flame rod if necessary.
Replace module if necessary.
Содержание EvenTube ETS
Страница 10: ...SERIES EVEN TUBE 10 10 03 2017 Specifications Dimensional Details ETS 50 Note All dimensions are in inches...
Страница 20: ...SERIES EVEN TUBE 20 10 03 2017 Installation Instructions Step 8 Step 9 Vent Hanger Primary Reflector...
Страница 23: ...SERIES EVEN TUBE 23 10 03 2017 Installation Instructions Step 14 Step 15 8 32 x 3 8 screws Secondary Reflector...
Страница 33: ...SERIES EVEN TUBE 33 10 03 2017 Installation Instructions You should now have a fully assembled ETS 50...