background image

TIP 

Use caution when screwing sections together, Hand tighten screw do not use a screwdriver.

TIP

 Posotioning your Reactor- You should now decide if you are positioning your reactor inside or outside of the sump.

Step 1

Loosen by hand, 

(do not remove)

 the 2 lid 

retaining screws at the top of the Gyractor 

(a)

 

and remove the lid 

(b)

, by slightly rotating the lid 

and lifting up.
Lift up the clear inner tube to access the blue 

filter sponge 

(c)

.

Lift out the top blue filter sponge 

(d)

 to gain 

access to the main cavity. 

Step 2

Place the desired quantity of Bio Phos 80 into 

the main body of the reactor, being careful not to 

allow any to fall down the centre feed pipe. 

(e)

It’s a good idea to block this pipe with your finger 

or a piece of kitchen paper. 

(f)

Step 3

Check the top of the main body to ensure there 

is no stray media that will prevent the lid from 

creating a  good seal when replaced. 

Step 4

Replace the top filter sponge and lid, being 

careful not to over tighten the plastic screws. 

Finger tight is sufficient to prevent any leaks. 

Step 5

Push the supplied connector into the pump inlet 

(1) 

followed by the pump 

(2)

. The pump will only fit in one 

position. 

(3)

Ensure bottom sponge is under the plastic plate and the 

small red seal is sitting above this. 

(4)

WARNING -

 the pump needs to be submerged in the 

sump

Step 6

At this point, you can power the reactor up.  The Bio 

Phos 80 media is very dense so there will be very little 

movement in the reactors.  The heavier mass allows 

water to pass through without causing channeling giving 

more even surface contact time.

Step 3 - Pump instructions

apply to pumps supplied by

iQuatics

At this point, you can power the reactor up. Some 

media may float to the top at first because air 

bubbles have stuck to it. 
A sharp tap on the side of the reactor will release 

most, any that remain will eventually fall back. 
Set the flow control to give a gentle simmer at the 

top of the Gyractor with a much more aggressive 

cleaning action at the bottom. The pump is 

purposely overrated to allow you to increase flow if 

the nozzles or top filter sponge start to clog slightly.
The best starting point on pump adjustment is 2 

clicks up from the lowest flow.

INSIDE SUMP

If you need to extend the pipework, you can use standard 19mm internal diameter Poly Pipe,

(a)

(a)

(c)

(4)

(1)

(2 )

(f)

(c)

(e)

Set the flow control on the pump.

+

-

(3)

Package Contents

iQuatics Bio Phos Reactor 

1 x Pump Connector

1 x SICCE Syncra 1.0 Silent Pump (If ordered

      with reactor from iQuatics)

Отзывы: