background image

©2011 IQtronic, Ltd 

 

 

 

Page 12 of 34 

TURNON1=123 

Turn the socket on for 123 minutes.   TurnedOn1 123 min 

Ctrl 

TURNON2=123 

Turn the auxiliary output on for 123 
minutes.  

TurnedOn2 123 min 

Ctrl 

RESTART 

Change (negate) state of the socket 
and the output for time preconfigured 
by command RESTARTTIME. 

Restarted 

Ctrl 

RESTART1 

Change (negate) state of the socket 
and the auxiliary output for time 
preconfigured by command 
RESTARTTIME. 

Restarted1 

Ctrl 

RESTART2 

Change (negate) state of the socket 
and the auxiliary output for time 
preconfigured by command 
RESTARTTIME. 

Restarted2 

Ctrl 

STATUS 

Get status of IQsocket IQSW-GSM: 
socket and auxiliary output, time, 
temperature, last power lost event, 
input state and GSM signal. 

Output:OFF/OFF, 
Time:yy/mm/dd,hh:mm:s
s, TEMP: 25

°

Signal:76%, Last PWR 
Lost: 
yy/mm/dd,hh:mm:ss, 
Input: Not connected, 
Alarm ACT. 

Ctrl 

RINGON 

A call-back to the sender‟s number 
will be made. Useful to keep-alive of 
credit in prepaid SIM cards. 

 

Ctrl 

 
 

 

Note… 

Maximum time value of TURNON command is 180 minutes. 

 

If a power failure occurs during TURNON= / TURNOFF= 

commands, time of power failure is not included in the 
countdown, so e.g. you need to run an appliance for a hour 

issuing TURNON=60 command, but AC power is lost after 
30minutes and restored back say after 2hours, appliance will 
be running for half an hour after power is restored back. 

 
Status message informs about Input alarm following ways: 
ON, if input alarm function is turned on,  
OFF, if input alarm function is turned off, 
ACT, if input detected an alarm state, 
DET, if input detected an alarm state but input alarm is off, 
DIS, in plug from the input jack has been removed (like a 
tamper indication) while alarm function is turned on. 

 

Содержание IQSocket IQSW-GSM

Страница 1: ...User guide www IQtronic com User Guide IQSocket IQSW GSM Version v1 0 rev3...

Страница 2: ...tures 15 4 7 Response messages settings 16 4 8 Scheduler feature 18 4 9 Thermostat function 20 4 10 Alarms 20 4 10 1 Power lost alarm 21 4 10 2 Defining phone numbers for SMS and ringing up alerts 23...

Страница 3: ...ent without further notice WARNING This product is not designed for use in and should not be used for medical applications The product doesn t guarantee safe power source disconnection only functional...

Страница 4: ...W GSM Output power socket Connect your electric appliance here This socket is intelligent can be controlled remotely manually or automatically scheduler Power plug Input of AC power for product and al...

Страница 5: ...f turn on off for a specified time restart by cutting power for short time of any electric appliance connected to the microrelay output jack by SMS or by call Monitoring of temperature temperature ala...

Страница 6: ...until you hear feel a click so it becomes locked inside bay To remove SIM from your IQsocket IQSW GSM gently push the SIM inside the bay until you feel and hear a click again card will become unlocked...

Страница 7: ...al socket Note Both the socket and the plug of the IQSW GSM follow the same international standard and nominal voltage rating Ensure you ordered proper international version of the IQSW GSM suitable f...

Страница 8: ...Input and Output connections Jack1 input GND Input 5V 50mA internally fused There is provided 5V 50mA power supply line for powering external sensors It is also possible to connect more than a single...

Страница 9: ...tch orientation is in position when the socket is in off state WARNING Please respect maximum rating of the auxiliary microrelay output 30VDC 0 5A Do not overload your IQSW GSM as this may damage or s...

Страница 10: ...blinks about every second searching of GSM network is in progress The Output LED Yellow indicates state of output socket Shining LED means socket is active appliance plugged into the output socket is...

Страница 11: ...about error messages Each command is normally confirmed by a response SMS sent back to the command sender number In case of an error is detected in a command IQSW GSM will respond with error message t...

Страница 12: ...s TEMP 25 C Signal 76 Last PWR Lost yy mm dd hh mm ss Input Not connected Alarm ACT Ctrl RINGON A call back to the sender s number will be made Useful to keep alive of credit in prepaid SIM cards Ctr...

Страница 13: ...START Change negate state of the socket and the auxiliary output for time preconfigured by command RESTARTTIME call is rejected RING RESTART OK Cfg RING RESTART1 Change negate state of the socket for...

Страница 14: ...wered on A SIM card must be inserted in the SIM bay 4 4 Timing setup Following table summarizes settings of time interval of RESTART command SMS Command Description SMS Response Type RESTARTTIME XX Co...

Страница 15: ...t device will ignore all SMS messages and calls received from numbers not included in the permitted phone numbers list If this security feature is not enabled device can be controlled by anyone who kn...

Страница 16: ...N Using of password SMSPIN is deactivated SMSPIN NOPIN OK Cfg SMSPIN Get configuration of SMSPIN parameter SMSPIN NOPIN 1234 Cfg Permitted phone numbers list accept up to 20 numbers must contain only...

Страница 17: ...ive for unauthorized numbers SMSCONFIRMUNAUTH NO OK Cfg RINGCONFIRM YES Phone call confirmation is turned on for all commands Hang off after 10 seconds RINGCONFIRM YES OK Cfg RINGCONFIRM NO Phone call...

Страница 18: ...numbers are recognized as follows 1 Monday 2 Tuesday 3 Wednesday 4 Thursday 5 Friday 6 Saturday 7 Sunday If symbol is inserted action will be executed daily If number of day within week is inserted ac...

Страница 19: ...0 o 19 00 5 INF Send Status SMS every Friday at 19 00 Note In order to use INF action sending status message it is necessary to configure target numbers first using ALARMNUMBER command see chapter 4 1...

Страница 20: ...THERMOSTAT OF F SOCKET JACK ON 20 OFF 25 Ctrl TEMPON 20 Temperature limit for turning on selected output if temperature threshold is reached or passed TEMPON 20 OK Ctrl TEMPOFF 25 Temperature limit fo...

Страница 21: ...MS Command Description SMS Response Type PWRALARM NOALARM Power alarm on power lost event is not active PWRALARM NOALARM OK Cfg PWRALARM LASTNUMBER On power lost event sends SMS alert to the number de...

Страница 22: ...ur Alerts are having following content GSM Socket PWR failed GSM Socket PWR restored Where text GSM Socket can be customized by user via DEVICENAME command SMS Command Description SMS Response Type DE...

Страница 23: ...alerts numbers in list are processed per their order the first number first the last number as last It is possible to define up to 6 numbers 4 10 3 Input alarm Alarm invoked by Inputs is having highe...

Страница 24: ...figured by command INPUTTYPE SMS Command Description SMS Response Type INPUTTYPE CHANGE Alarm is activated at every change of input state INPUTTYPE CHANGE OK Cfg INPUTTYPE HIGH Send alert SMS every ti...

Страница 25: ...s in parentheses ALARM SMS RING Cfg Note Alert by ringing up calling target telephone numbers is supported only for alarms invoked by inputs Input event log Up to 5 five last input change events are s...

Страница 26: ...X OK Ctrl TEMPALARM MIX Temperature alarm is active for both lower and upper limit TEMPALARM MIX OK Ctrl TEMPALARM Get configuration of TEMPALARM active setting is in parentheses TEMPALARM NO MIN MAX...

Страница 27: ...and placement and also on background noise Microphone is activated by either answering a call from your IQSW GSM such as when an input alarm has been detected while alarm alert is set to ring using AL...

Страница 28: ...s of state that was at time of disconnecting power power lost OUTPUT OFF OK Cfg OUTPUT ON When powered on power restored output socket state will be set to ON regardless of state that was at time of d...

Страница 29: ...command or wrong SMSPIN Not allowed In case of permitted phone numbers list is active but used number is not included in it Timeout 10 minutes interval of configuration mode has expired In order to co...

Страница 30: ...to GSM network BLINKING GREEN EACH SECOND Not logged to GSM network yet searching LIGHTS GREEN 2 x PER SECOND SIM card have active PIN protection use a GSM phone to disable it OUTPUT NOT ACTIVE Outpu...

Страница 31: ...ll LED indicators should start blinking for next 10 seconds Please press the button again within these 10 seconds to confirm reset to factory default procedure After this step is your device in origin...

Страница 32: ...1900 Class1 1W SIM card Plug in 3V Antenna Integrated antenna standard models External 2dBi via SMA F connector models Indicators POWER red LED GSM green LED RELAY yellow LED Features Appliance contro...

Страница 33: ...influence to other electronic systems Don t expose product to vibrations shaking or fall downs to avoid product damage When use sound monitoring for taping purposes ensure you have prior permission t...

Страница 34: ...ct family W WALL R RACK D DIN B Board Product model GSM GSML GSMRF IP RS232 HDO IPGSM Electric standard of plug socket F Schuko E French B British N USA Ordering code Code Description IQSW GSM X stand...

Отзывы: