VCP-01B
Device differences
VCP-01B differs from VCP-01 in the following:
•
RS-485 interface added, 3.3V or 5V levels selectable
•
Graphic library extended by a set of MICRORISC functions
•
Console CCP command interpreter added
•
Tilt sensor LIS33DE and LIS2DH can alternatively be used
Electrical specifications
(
typical values
unless otherwise stated)
Power supply
7 – 20V DC (terminal clamp) / 5.0 ± 0.35 V DC (micro USB)
Accumulator LI14500-700-1L, 3.7 V, 700 mAh, Li-Ion, AA
Display
DI-QVGA-3.2-03 TFT LCD 3.2“, 320 x 240 pixels, 256
K colors
Supply current
operational
160 mA
1
(display backlight off)
280 mA
1
(display backlight on)
sleep mode
80 µA to 110 µA
2
power-down mode
8 µA
2
accumulator charging
450 mA max.
Temperature range
operational
0 °C to +60 °C
accumulator charging
0 °C to +45 °C
Frequency range
868 MHz or 916 MHz (according to the TR module)
RF output power 3.5 mW
Supported TR modules TR-52BA (with on-board PCB antenna)
Temperature sensor accuracy
±0.5 °C typ., ±3 °C max.
Dimensions
120 mm x 80 mm x 28 mm
Display size
8.1 mm (diagonal)
Weight:
143 g
3
Note 1: This current is increased due to charging in case of external supply (depended on the accumulator state).
Note 2:
All peripherals shut down.
Note 3:
Including accumulator and TR module, without micro SD card.
Absolute maximum ratings
Stresses above those values may cause permanent damage to the device. Exposure to maximum rating conditions
for extended periods may affect device reliability.
Supply voltage (VCC):
20.5 V DC (terminal clamp) / 5.5 V DC (micro USB)
Storage temperature:
-30 °C to +80 °C
© 2015 IQRF Tech s.r.o.
www.iqrf.org
User_Guide_VCP-01B_180118