IQRF GW-USB-05 Скачать руководство пользователя страница 4

GW-USB-05

Hardware

GW-USB-05 consists of main MCU, memories and the TR-52D compatible circuitry with RTCC added. Firmware of  
the main MCU is fixed. Specific functionality of the device can be implemented by user software for the TR module. 
Application for TR module inside (except of RTCC usage) can also be developed using the CK-USB-04 development  
kit. For detailed information refer to CK-USB-04 User's guide.

Power supply

GW-USB-05 is intended to be supplied from a host via USB connector. LDO voltage regulator converts 5 V from USB 
to 3.3 V for all internal circuitry. RTCC has a temporary backup by decoupling capacitors, see below.

Reset

Reset can be invoked by connecting a disconnected GW-USB-05 to USB or by the 

Reset USB Device 

command in 

CDC   mode.   Actual   reset   is   executed   ~5  s  after   the   command   is   issued.   This   delay   allows   to  disconnect   USB 
communication on host side in time. See the user's guide 

CDC Implementation in IQRF USB devices

.

USB

The device supports two USB modes:

Custom Device mode

Full communication with the IQRF IDE is enabled in this mode. The GW uses identical USB driver like e.g. CK-
USB-04. It is possible to upload the application into internal TR module, display data received from SPI interface of  
the TR in IQRF IDE Terminal etc. The user can easily create his own PC program using the  

mpusbapi.dll 

library. See USB Custom Device Example on IQRF website.

CDC mode

After connecting to PC a virtual serial port is created in this mode. The user can create his own PC program and  
communicate via this port using the protocol described in document 

CDC implementation in IQRF platform

.

Switching between the modes:

From Custom Device to CDC: 

Using IQRF IDE 4 or higher: 
Tools → USB Classes → Switch to CDC mode.

From CDC to Custom Device: 

Using IQRF IDE 4 or higher: 
Tools → USB Classes → Switch to Custom Device mode.

Using the 

Switch to USB Custom Class

 command in CDC protocol.

Current mode indication see chapter LED. The last selected mode is restored after start-up or reset.

Tip

For testing a communication in CDC mode various SW terminals operating with PC serial ports are available. Select 
a terminal enabling to issue direct byte commands and data. Refer to the communication protocol described in CDC 
Implementation in IQRF USB devices User's guide. 
Recommended terminal: Docklight, 

www.docklight.de

. There is a project containing all supported commands for 

this terminal available at 

www.iqrf.org/218

. It is necessary just to select the COM port used.

Unsuitable terminal: Windows Hyperterminal, Tera Term.

TR module

Wireless   IQRF   transceiver   module   compatible   with  TR-52D,   without   temperature   sensor.   Refer   to   the   TR-52D 
datasheet for details.

Antenna

PCB antenna on GW-USB-05 board.