Battery replacement

The RT322 runs on 2 x type AAA (Alkaline) non rechargeable batteries and is designed to 
give a battery life of approximately two years. 

When the batteries are nearing the end of their life a 
low battery symbol will appear in the display and the 
batteries should be changed within a few days. If the 
batteries are not changed at this point eventually a 
‘LO’  battery  message  flashes  intermittently  in  the 
display and if this happens the batteries should be 
changed immediately.

To change the batteries it is necessary to remove the thermostat from the wall. To do this 
first undo the two captive screws at the base of the thermostat and swing the thermostat 
up and away from the wall plate.

Remove the old batteries and replace them with two new AAA 
size alkaline batteries ensuring that they are fitted correctly as 
indicated by the terminal markings in the battery compartments.

Once the batteries are fitted, re-fit the thermostat to the wall plate 
by engaging with the lugs at the top of the wall plate and push the 
thermostat into position. Locate it over the captive screws at the 
base of the wall plate and tighten so that the thermostat is locked 
into position.

Check the temperature setting is correct and adjust if necessary.

Please dispose off the batteries responsibly.

Receiver unit

The receiver unit receives the Z-Wave radio signals from the 
room  thermostat.  In  the  unlikely  event  of  a  communication 
failure it is possible to override the system and switch On and 
Off using the On/Off buttons on the receiver as a local override. 

If  the  override  is  used  to  override  the  thermostat  when  it  is 
functioning correctly then the override will be cancelled by the 
next  switching  operation  of  the  thermostat  and  normal 
operation  will  be  resumed.  In  any  case,  with  no  further 
intervention, normal operation will be restored within one hour 
of the override being operated.

4

Batteries should be
changed immediately

Low battery symbol 
appears first when the
batteries are nearing the 
end of their life

Содержание RT322

Страница 1: ...es interoperable two way RF mesh networking technology to provide optimum comfort with close control of the energy used to heat the home without the need for additional wiring or unsightly cable runs...

Страница 2: ...2...

Страница 3: ...conds before returning to the set temperature When the thermostat is in the call for heat condition a flame symbol will appear in the display The aerial symbol complete with radio wave symbols in the...

Страница 4: ...teries are fitted re fit the thermostat to the wall plate by engaging with the lugs at the top of the wall plate and push the thermostat into position Locate it over the captive screws at the base of...

Страница 5: ...tted with the retaining screws located at the bottom and in a position which allows a total clearance of at least 50mm around the receiver Direct Wall Mounting Offer the plate to the wall in the posit...

Страница 6: ...terminating any cable earth conductors Earth continuity must be maintained and all bare earth conductors must be sleeved Ensure that no conductors are left protruding outside the central space enclos...

Страница 7: ...ntrol basic layout This diagram shows a receiver used in a conventional fully pumped system using a 2 port spring return zone valve with auxiliary switch to control the pump and boiler Please note hot...

Страница 8: ...e will be enough space to allow easy access to the two retaining screws located at the base of the wall plate Before fixing the wall plate in position check to see that the thermostat and Receiver are...

Страница 9: ...iler the TPI thermostat will help to save energy as the control algorithm allows the boiler to operate in condensing mode more consistently compared to older types of thermostat DIL switch numbers 7 a...

Страница 10: ...t 3 The network LED on the receiver should be flashing 4 Press the dial on the front of the RT322 thermostat once so that the I in the display flashes 5 Press and hold the network button on the receiv...

Страница 11: ...ear in the display which now shows PP 4 Turn the dial until the letter I appears in the display and return to the main instruction Stage 2 Only used if the above procedure does not establish a success...

Страница 12: ...ting temperature range 0 40 C Double Insulated Case material Thermoplastic flame retardant Receiver specification Power Supply 230VAC 50Hz Contact type Micro disconnection Voltage free Contact rating...

Отзывы: