IQAir HyperHEPA Allergen 100 Скачать руководство пользователя страница 10

11

Chapter 4 – Using the Control Panel

4.1.1 Description of Control Panel Keys

Power Key
The Power key switches the IQAir system on and off. When the system is switched off, the fan stops to run, but

the system will remain connected to the power supply (standby mode).The standby mode allows for automatic timer
start-up. In the standby mode, the different menu functions can be accessed. Tip: In a menu window the Power key
also serves as a quick exit key to return to the main display window.

Arrow (

) Key

When the system is switched on, the

key allows the adjustment of the fan speed. In the enter mode, indicated

by the appearance of a black flashing cursor (see “Enter Key” below), the

key is used to modify the selected setting

in the display window. Confirmed with the Enter key, the enter mode is automatically terminated. The LCD will then
display the current menu settings for another 15 seconds before reverting to the main window display.

Chapter 4 – Using the Control Panel

The IQAir system is operated and controlled via the electronic control panel which is located at the top of the front
locking arm.

Several operations can be completed via the electronic control panel, including:

Switching the system on and off

Controlling the fan speed and corresponding air delivery rate

Checking the remaining filter life of the individual filters

Setting the automatic timer

Resetting the Filter Life Monitor after replacing a filter

Locking the control panel to avoid tampering with the system’s settings

Choosing the desired display language

4.1 Description of Control Panel Elements

LCD = Liquid
Crystal Display

Power

Key

Enter

Key

Menu

Key

Arrow

Key

HyperHEPA® Filter Life LED

PreMax

TM

Filter Life LED

Timer LED

Fan Speed LEDs

LCD Display

The 2-line LCD displays important information about the system’s settings. In
standby mode, the first line shows the current day and time. If the timer is
activated, the programmed start and stop times will be displayed on the second
line.

If the IQAir system is on, the first line displays the current speed setting and the
second line displays the corresponding air delivery rate of the system. By
pressing the Menu key, ten active menu functions may be accessed. These
functions are explained in detail in this chapter.

LED = Light Emitting Diode

Main window: Standby mode

Main window: On mode

Menu window: Filter Life monitor

All manuals and user guides at all-guides.com

Содержание HyperHEPA Allergen 100

Страница 1: ...0 HyperHEPA High Performance Air Cleaning System for Advanced Airborne Particle Control User s Manual HB A100 GB_0407 105 10 31 12 Swiss Made All manuals and user guides at all guides com a l l g u i...

Страница 2: ...s appliance for its intended purpose of air cleaning in non industrial environments Do not use this appliance in areas with very high concentrations of dusts or powder to prevent the danger of dust ex...

Страница 3: ...5 4 4 4 Setting the Weekly Timer 16 4 4 5 Timer ON OFF Fan Speed Selection 16 4 4 6 Timer Information in the Control Panel 17 4 4 7 Time Day Setting 17 4 4 8 Filter Life Reset 18 4 4 9 Changing Airflo...

Страница 4: ...air is high or the indoor air quality requirements are stringent the hourly air delivery of the system needs to exceed the room air volume several times To achieve that level of air turnover it may b...

Страница 5: ...ren Sie uns unter info incen com oder der Faxnummer 41 71 844 0845 Um eine reibungslose Bearbeitung Ihrer Service Anfrage zu gew hrleisten halten Sie bitte folgende Angaben bereit Modellname Artikel u...

Страница 6: ...a soft and clean surface Place the mounting rail on the purifier s base so that the holes line up with the black connector pins on the base The cut ins should face the center of the unit Press down u...

Страница 7: ...general the more centrally the system is positioned the better the performance Position the system close to a power outlet and make sure that the power cable is positioned in a way that it does not p...

Страница 8: ...penings on two sides The PreMaxTM filter module consists of frame 1 and the PreMaxTM filter which is fixed inside the frame by four filter clamps The fan assembly comprises two housing modules with th...

Страница 9: ...ghtly pleated HyperHEPA filter media that removes even the tiniest particles 5 Low turbulence low velocity air is returned to the room via the EvenFlow diffuser 3 2 Description of Removable Components...

Страница 10: ...Several operations can be completed via the electronic control panel including Switching the system on and off Controlling the fan speed and corresponding air delivery rate Checking the remaining filt...

Страница 11: ...n airflow particle filters are clogged or a reduction in filter efficiency gas phase filter is saturated Fan Speed LEDs These LEDs simulate the fan speed through the frequency of their rotation The fa...

Страница 12: ...cific environment are calculated as follows hourly air delivery of the IQAir system m3 h air changes per hour ACH air volume of the room m3 N B The air delivery rates at the various fan speeds setting...

Страница 13: ...memory bank which contains infor mation about the different filters lives under specific conditions of use The Filter Life Monitor makes a calculation of the remaining filter life taking into account...

Страница 14: ...the Menu key twice 2 Press and hold the Enter key until the cursor starts to flash 3 Press the key once to activate the timer Note If the start and stop time are identical the timer cannot be activat...

Страница 15: ...e 4 4 4 Setting the Weekly Timer The weekly timer allows the activation deactivation of the Timer ON period on certain days of the week In its default setting the timer is enabled on all seven days of...

Страница 16: ...ursor starts to flash 3 Select the hour by pressing the key 4 Press the Enter key to save the hour setting and to proceed to the minute setting 5 Select the minutes by pressing the key 6 Press the Ent...

Страница 17: ...nu key eight times The current display language is displayed 2 To change the display language press and hold the Enter key until the cursor starts to flash 3 Use the key to scroll through the display...

Страница 18: ...long periods of time This dust group is made up of small combustion particles that are created as the result of combustion processes of automobiles small allergen particles such as cat allergens toba...

Страница 19: ...Press and hold the Enter key until the cursor appears 7 Press the key to modify the Fine Dust index to reflect the fine dust pollution levels found in the environment where the system is used for gui...

Страница 20: ...e timer on and off with the remote control To switch the timer on press the Timer Modification key and then the Timer ON key To switch the timer off press the Timer Modification key and then the Timer...

Страница 21: ...the IQAir system on the right side of the control panel shows the positions of the individual filters These positions correspond to the actual positions of the filters within the system 6 2 Ordering...

Страница 22: ...snap in position in the diffuser Disengage the other arm in the same way 3 Pull both locking arms evenly outwards until they snap into place and remain open Access to all filter elements is now possib...

Страница 23: ...For details on how to close the housing please refer to the section 6 3 8 Dispose of the used filter by placing it into the plastic bag in which the new filter is supplied 7 Lift the frame from the fi...

Страница 24: ...d see the section 6 7 9 Put frame 2 back into the housing and reposition the diffuser For closing refer to the section 6 3 Frame 2 6 6 Discarding Used Filters Used filters can normally be put into the...

Страница 25: ...ting of the IQAir system where floor space is limited InFlow Complete ducting adapter kit for the creation of positive pressure if placed within the room and negative pressure if placed outside the ro...

Страница 26: ...INCEN AG Blumenfeldstrasse 15 CH 9403 Goldach Switzerland Tel 41 71 844 0844 Fax 41 71 844 0845 email info incen com www iqair com All manuals and user guides at all guides com a l l g u i d e s c o m...

Отзывы: