IQAir HealthPro Plus Скачать руководство пользователя страница 48

5.7  Replacing the HEPA Filter (Filter 3)

Chapter 5  Replacing Filters 

.

5-11

3.

Follow the instructions on the next page to replace the 
HEPA filter element.

1.

Open the locking arms, making sure they 
are fully extended outwards.
(For details, refer to page 5-3.)

2.

Opening the arms will release the top housing
modules. Removing the diffuser will reveal the 
HEPA filter element which is located inside 
Frame 3.

Frame 3

Diffuser

HEPA filter element

Frame 3

Содержание HealthPro Plus

Страница 1: ...High Per for mance IQAir Air Cleaning System U s e r s M a n u a l H e a l t h P r o P l u s IQAir Inc USA...

Страница 2: ...become damaged it may be replaced with a similar cord set as is commonly used for computers and similar appliances Only use this appliance for its intended purpose of air cleaning in non industrial e...

Страница 3: ...portant Safety Instructions Please read this first Introduction Air Cleaners and Indoor Air Quality Chapter 1 Setting Up Your IQAir Cleaner Chapter 2 Your IQAir Cleaner and its Components Chapter 3 Us...

Страница 4: ...3 USING THE CONTROL PANEL 3 1 3 1 Description of Control Panel Elements 3 1 3 2 Fan Speed and Air Delivery 3 3 3 2 1 Regulating Fan Speed 3 3 3 2 2 Changing Air Volume Units 3 3 3 2 3 Air Exchange Rat...

Страница 5: ...using 5 6 5 5 Replacing the Pre Filter Filter 1 5 7 5 6 Replacing the Gas Odor Filter Filter 2 5 9 5 7 Replacing the HEPA Filter Filter 3 5 11 5 8 Discarding old Filters 6 1 Chapter 6 CARING FORYOUR A...

Страница 6: ...lter replacement A daily and weekly timer to automatically switch your air cleaner on and off at a preset time A countdown timer to allow your IQAir cleaner to run for a set number of hours before aut...

Страница 7: ...ner should be at least double the air volume of your room If the rate at which pollutants enter the room air is high or the indoor air quality require ments are stringent the hourly air delivery needs...

Страница 8: ...ull it out of the box Remove the plastic bag and foam belt The power cord and the remote control are located in a small cardboard box underneath the base of the air cleaner Keep the packaging for futu...

Страница 9: ...source the better the air cleaning performance in the room Although an air cleaning result may be achieved in adjacent rooms the main air cleaning will take place in the room where the air cleaner is...

Страница 10: ...nnect power completely is to unplug the power cord Do not use the air cleaner when the power cord becomes damaged The power cord may be replaced with an approved cord with a two pole plug These power...

Страница 11: ...s the LCD display on some IQAir cleaner models This film should be removed to enable clear viewing of the LCD To take the protective film off loosen it first on one corner with your finger and then re...

Страница 12: ...me 2 and the gas odor filter element 2 1 Description of Housing Components Your IQAir cleaner features a modular tower design in which all important filtration and air moving components are positioned...

Страница 13: ...ription of Removable Components The HEPA filter module consists of frame 3 and the HEPA filter element The HEPA filter is held down by the diffuser The diffuser contains omni directional air outlet op...

Страница 14: ...the heart of the unit sandwiched between the filters is a powerful centrifugal fan which generates the air flow The air is pushed through a gas odor filter that retains wide spectrum of gases and odo...

Страница 15: ......

Страница 16: ...r Life LED Filter 3 Filter Life LED Filter 2 Filter Life LED Filter 1 Timer LED see page 3 10 Fan Speed LEDs 3 1 Chapter 3 Using the Control Panel LCD Display The 2 line LCD displays important informa...

Страница 17: ...h the control settings To lock or unlock the control panel keys the Menu and the Enter key have to be pressed down simultaneously for 3 seconds The activated locking function is indicated with a star...

Страница 18: ...the far left of the control panel 2 The LCD now displays the fan speed and the corresponding air flow rate Note the air cleaner starts at the fan speed at which it was running when it was last used 3...

Страница 19: ...chieve a significant air quality improvement If the intensity of the pollution source is high or a high degree of purification is needed the hourly air changes may have to be considerably higher In or...

Страница 20: ...nd change the current time and day setting 2 Daily Timer Menu Allows you to view and enter a start and stop time at which the unit will automatically switch on and off It also allows you to activate d...

Страница 21: ...w When the last modifiable choice in a menu has been confirmed with the Enter key the enter mode is automatically terminated The LCD will then display the current menu settings for another eight secon...

Страница 22: ...y until the cursor starts to flash 3 Enter the hour by pressing the key 4 Press the Enter key to save the hour setting and to proceed to the minute setting 5 Enter the minutes by pressing the key 6 Pr...

Страница 23: ...nute setting by pressing the key Note The minute settings can only be set in five minute increments 8 Press the Enter key to save the start time and to proceed to the stop time setting Chapter 3 Using...

Страница 24: ...h a star for the daily timer to run If the timer is disabled on all days of the week the timer status field in the Daily Timer will switch to OFF and the timer will be disabled 1 To reach the Weekly T...

Страница 25: ...hen the unit will next switch on 3 or when it actually switched on 4 This is followed by the time when the air cleaner will switch off If the start time is before 00 00 hours and the stop time after 0...

Страница 26: ...e daily timer also be enabled the countdown timer will take priority until the countdown period has elapsed 2 Press down the Enter key until the black cursor appears 3 Press the key to enter the desir...

Страница 27: ...particles This type of dust is smaller than 0 003 mm 3 m in size and will remain airborne for long periods of time This dust group is made up of small combustion particles that are created as the resu...

Страница 28: ...ignificant effect on filter life If tobacco smoke exposure is regular the following values should be added to the appropriate filter load indexes Tobacco smoke presence Large Dust Index Fine Dust Inde...

Страница 29: ...x 7 To modify the gas index press the key 8 Press the Enter key to save the gas index setting and to exit the enter mode 3 Press the key to modify the large dust index 1 Press the Menu key five times...

Страница 30: ...rent speed setting and the set filter load indexes The assignment of filter numbers to actual filter elements is as follows Filter 1 Pre filter element Filter 2 Gas odor filter element Filter 3 HEPA f...

Страница 31: ...t Index Calculated Life of Pre Filter in hours 1 49 342 32 895 24 671 19 737 13 158 9 868 6 579 4 934 3 289 2 27 174 18 116 13 587 10 870 7 246 5 435 3 623 2 717 1 812 3 18 750 12 500 9 375 7 500 5 00...

Страница 32: ...the wrong filter has been selected or if you wish to exit the enter mode simply press the Menu key This will leave the filter life controller unaffected 5 To confirm the filter change and exit the New...

Страница 33: ...Air model and the country of purchase 1 To reach the Display Language Menu from the main display window press the Menu key eight times The current display language is displayed 2 To change the display...

Страница 34: ......

Страница 35: ...e and deactivate the timer Start and stop times of the timer can only be changed directly from the control panel Note The system can still be operated with the remote control even if the control panel...

Страница 36: ...into maximum speed Keys 2 and 3 will put the air cleaner into medium speeds Note Your air cleaner can only be put into four different speeds with your remote control even though you may access more sp...

Страница 37: ...lacing the batteries make sure that you are within the transmission reach for remote control operation see illustration 4 3 and that the batteries are placed correctly within the battery compartment 4...

Страница 38: ...lter Filter 3 corresponds to Filter 2 corresponds to HealthPro Plus only Filter 1 corresponds to Your air cleaner features a modular housing design which enables easy replacement of all filter element...

Страница 39: ...e article numbers stated below IQAir HealthPro Plus Pre filter element Art No 102 10 10 00 Gas odor filter element Art No 102 18 10 00 HEPA filter element Art No 102 14 14 00 IQAir HealthPro Pre filte...

Страница 40: ...that hook into the diffuser from opposite sides To open your air cleaner follow the steps below 1 Disconnect your air cleaner from the power supply before attempting to open the unit 2 Press the firs...

Страница 41: ...ms evenly toward the outside until they click into place The top five modules of the air cleaner housing will now be lifted from the two lower modules resting on the arm extentions The air cleaner wil...

Страница 42: ...f the unit 1 Position yourself on the side of the air cleaner Place one hand on the top edge of each locking arm Push both locking arms in toward the center of the unit until they completely snap into...

Страница 43: ...er simultaneously Problem 2 The air cleaner cannot be switched on again after closing Reason 2 The lower filter module has been left out This leaves a microswitch disengaged Solution Open the unit aga...

Страница 44: ...slowly 4 As the frame is withdrawn from the unit tilt it progressively upward to remove it completely 1 Open the locking arms making sure they are fully extended outward For details refer to page 5 3...

Страница 45: ...ispose of the used filter by placing it into the plastic bag in which the new filter is supplied 10 Turn the frame around and insert the new filter Ensure that the arrows on the pre filter label point...

Страница 46: ...structions on the next page to replace the gas odor filter element 1 Open the locking arms making sure they are fully extended outwards For details refer to page 5 3 2 Opening the arms will release th...

Страница 47: ...s odor filter element by lifting it out of the frame 5 Insert the new filter element ensuring that the correct side is facing up 6 Put the frame back onto the housing followed by frame 3 and the diffu...

Страница 48: ...place the HEPA filter element 1 Open the locking arms making sure they are fully extended outwards For details refer to page 5 3 2 Opening the arms will release the top housing modules Removing the di...

Страница 49: ...the used filter element by placing it into the plastic bag in which the new filter is supplied 9 Turn the frame around and insert the new filter Ensure that the arrows on the label of the filter eleme...

Страница 50: ...monitor which is designed to assist you in determining when a filter element needs to be replaced If the pollution load is extremely high and the filter load indexes are not set appropriately there i...

Страница 51: ...d every time a filter is replaced or when the system is relocated The test must be repeated every 6 months This is essential when IQAir systems are used to filter highly infectious microorganisms e g...

Страница 52: ...ducting adaptors InFlow W125 and OutFlow W125 allow for the creation of pressure differences between adjacent environments These pressure differences help to create directional airflows which can gre...

Страница 53: ...120w 3 150w 4 170w 5 205 w 6 215 w 115V 50 60Hz H 28 x W 15 x D16 HealthPro 29 lbs HealthPro Plus 35 lbs 5 years on unit including fan motor excluding filter elements 1 Pre filter 2 Cleanroom grade H...

Страница 54: ...structions or to damage caused during transit to or from the purchaser IQAir will not be liable under this warranty for any fault or damage arising from defective workmanship if the unit has been serv...

Страница 55: ...receipt 8 3 Warranty and Product Registration Card Please complete and return this card soon after purchase The information will permit us to keep you up to date with any necessary information relati...

Страница 56: ...IQAir Inc 1785 Locust Street Unit 2 Pasadena CA 91106 From Stamp...

Отзывы: