DO NOT REVERSE BATTERY POLARITY AT THE
BATTERY OR THE CIRCUIT BOARD. SEVERE DAMAGE WILL
OCCUR
The IntelliSlide X6 is a 24 volt DC gate operator. Utilizing (2) 12 vdc batteries,
the batteries must be connected in series, and then the positive (+) power
wire (RED) is to be connected to the positive (+) battery terminal
•
Take note of the software version on the LCD display upon power up.
Chain Attachment and Limit Settings
Using the supplied chain brackets, mount the
brackets with the chain bolt holes at the same height
as the bottom of the idlers. Roughly 9-10 inches from
the base of the operator.
Once the chain is attached, it needs to be tightened.
Be careful not to over tighten the chain. Proper
adjustment is 1-2” of sag for every 10’ feet of chain.
After the chain has been installed, the magnetic limits need to be installed. To do so, switch the
MOTOR SWITCH to the MANUAL position. Push the gate in the open direction until the gate
reaches the full open limit. Attach the Magnetic Limit Block to the chain so that it is flush with the
edge of the operator frame on the road side opening. Then, push the gate closed to the desired
closed position. Attach the Magnetic Limit Block to the edge of the operator frame on the opposite
edge of the operator frame.
Be sure to install positive stops at each end of the gate. The positive stops should be no more
then 2 inches beyond the limit travel
13