Installation procedures
If all the wiring is in place including the network cabling (not included in the above diagrams) then you are
ready to install the iBP6.
Line up the existing cable ways on the back of the supplied iPB6 back plate. Under no circumstances should
any back plate other that the supplied iPulse back plate be used. The supplied back plate should also not be
modified in any way. Ensure that you are mounting the back plate on a flat rigid surface. If the surface is not
flat or rigid the reader will not line up with the back plate and will not seal properly. Fasten the back plate with
the appropriate screws for your installation.
You can now connect the specified cables to the iPB6. Remember you will require Power, Network, and Relay
cables. When connecting the reader it is advised to not be doing it with live power cables, If everything is
connected you can slide the iPB6 reader onto the back plate lining up the top and bottom pillars correctly. If
you have done this the screw holes at the top and bottom should now line up. You might need to supply a bit of
pressure to get them to line up properly but this is normal.
If all your cabling has been completed you can now boot up your reader. Note that in the bottom left of the
reader’s screen there are two icons indicating network connectivity and relay connectivity. The first icon shows
connection to a relay if this icon is green the relay is detected. The second icon shows network connectivity,
this icon will have a red line through it if there is no network connectivity.