Position Code Procedure
The winding handle position relative to the angle of the nose sub-assembly can be rotated
through 360°, in 8.5° steps, to achieve the best winding position. Starters are made to a pre-set
position in the factory that should be right for your application. If however, you require an
alternative position follow the steps below:
1.
For the factory built position code, refer to outline or general
arrangement drawing.
2.
For an alternative position code, decide on the angle between the
release lever and input adaptor to suit your application (e.g. your
selected angle = +10°).
3.
Select the nearest position code from the table below (e.g. 8.5°+ = 2B).
4.
To achieve the selected (2B) position code, align the hole next to the
letter '0' at the front end of the body, against the hole designated '2' on
the front housing. Use the correct through bolt to secure the front
mounting bracket, the housing and the body in this position. (Note: For
starter without separate mounting bracket secure housing assembly to
the body).
5.
Place the rear housing on the body and align the radial hole 'B' against
the letter '0' on the body. Secure the body and the rear housing in this
position.
6.
Fit the remaining screws and tighten to a torque of 6-8 Nm.
Clockwise is + angle;
anti-clockwise is
–
angle
Datum line