General Maintenance

7. Periodically clean and examine exhaust system.

8. Keep dryer area clean and free of gasoline, combustible

materials and other flammable liquids or vapors.

9. Do not obstruct the flow of combustion (make-up) air and

ventilating air.

10. Check gas pressure periodically.

11. Gas burners air inlet shutters can be adjusted for proper flame

by following instructions outlined on separate page of this
manual.

12.

Main Basket Bearings.

 Lubricate once every six months

using six grams of high temperature grease. Do not over-
grease.

13.

Steam Heating Units.

 Keep steam coils clean. Check

periodically and clean as often as required. Remove lint and
dirt accumulation from coil fins to avoid decreasing their
efficiency.

14.

Clean Out Panel (Energy Saver Gas Models Only).

 Remove

this panel located on the energy saver heating unit and clean
the inside area of lint and dirt on a regular basis.

GENERAL
MAINTENANCE

Содержание DR30SLE

Страница 1: ... 99 5C D0539 MODELS GAS STEAM ELECTRIC DR30SLG DR30SLS DR30SLE OWNER S MANUAL 30 Lb Laundry Dryer THIS MANUAL MUST BE GIVEN TO THE EQUIPMENT OWNER IPSO USA 3101 S Haven Hwy 77 Phone 850 271 8486 Suite A Panama City FL 32405 USA ...

Страница 2: ...l occupants Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier WARNING In the event the user smells gas odor instructions on what to do must be posted in a prominent location This informa...

Страница 3: ...Ne touchez a aucun interrupteur Ne pas vous servir des telephones se trouvant dans le batiment ou vous vous trouvez Evacuez la piece le batiment ou la zone Appelez immediatement votre fournisseur de gaz depuis un voisin Suivez les instructions du fournisseur Si vous ne pouvez rejoindre le fournisseur de gaz appelez le service des incendies __ l installation et l entretien doivent etre assures par ...

Страница 4: ...ps wrinkles from setting in and reduces the possibility of spontaneous combustion WARNING Be safe shut main electrical power and gas supply off externally before attempting service WARNING Never use drycleaning solvents gasoline kerosene or other flammable liquids in the dryer FIRE AND EXPLOSION WILL OCCUR NEVER PUT FABRICS TREATED WITH THESE LIQUIDS INTO THE DRYER NEVER USE THESE LIQUIDS NEAR THE...

Страница 5: ...ubles to adjust remove or replace defective equipment or a part nor does it include any responsibility for transportation expense which is involved therein The warranty of IPSO is contingent upon installation and use of its equipment under normal operating conditions The warranty is void on equipment or parts that have been subjected to misuse accident or negligent damage operated under loads pres...

Страница 6: ... 24 25 DryerInstallationwithSeparateExhaust 26 Make Up AirRequirements 2 7 ExhaustandVenting 2 8 RulesforSafeOperationofDryer 2 9 OperatingInstructions CoinMeterModels 30 33 PAGE Service Savers 34 Troubleshooting 35 38 DirectSparkIgnition 39 40 GeneralMaintenance 41 42 BurnerAirInletShuttersAdjustment 43 44 BearingReplacementInstructions 45 BasketAlignment 46 ShimmingtheBasketandSpiderAssembly 47 ...

Страница 7: ...marrage Start arranquedeunmovimiento emission of heat in general êmission de chaleur en general Warmeabgabeallgemein emisióndecalor cooling refroidissement Kühlen enfriamiento dangerousvoltage tensiondangereuse Gefährlicheelektrische Spannung tension peligrosa SYMBOLS Symbol Description The following symbols are used in this manual and or on the machine ...

Страница 8: ...deuxsens DrehbewigunginzweiRichtungen movimientorotativoenlosdos sentidos End of Cycle caution attention Achtung atencion precaucion directionofrotation sens de mouvement continu de rotation DrehbewegunginPfeilrichtung movimientogiratorioorotatorio en el sentido de la flecha ...

Страница 9: ...w free access to the rear of dryer for future servicing of belts pulleys and motors Installation clearance from all combustable material is 0 ceiling clearance 0 rear clearance and 0 side clearance Before operating dryer open basket door and remove blocking between front panel and basket Read the instruction tags owner s manual warnings etc IMPORTANT Openingtheclothesloadingdoordeactivatesthedoors...

Страница 10: ...Page 10 L28UR30 Outline Dimensions Gas Steam and Electric Models ...

Страница 11: ...Page 11 L28US30 Outline Dimensions Gas Model ...

Страница 12: ...et Weight 495 lb 225 kg approx Domestic Shipping Weight 526 lb 239 kg approx 1 carton Export Shipping Weight 664 lb 301 kg approx 1 box Maximum Air Displacement 700 cfm 1190 m h Recommended Operating Range 530 630 cfm 900 1070 m h Gas Supply 1 2 DN15 pipe connection Btu Input 100 000 Btu per hour natural and LP gases Electronic Ignition Direct spark ignition system Net Weight 437 lb 198 kg approx ...

Страница 13: ...arton Export Shipping Weight 526 lb 239 kg approx 1 box Export Shipping Dimensions 74 L 1880 mm x 35 W 889 mm x 55 H 1397 mm Maximum Air Displacement 700 cfm 1190 m h Recommended Operating 530 630 cfm Range 900 1070 m h Heater Input 21 kW h 18 061 kcal h Total Heater Current See chart on separate page Net Weight approx 463 lb 210 kg Domestic Shipping Weight 498 lb 226kg approx 1 carton Export Ship...

Страница 14: ...MTR300 115 200 240 60 1 1 2 37 6 2 3 1 1725 MTR300 200 240 50 1 1 2 37 3 7 1425 MTR214 208 230 460 60 3 1 2 37 2 5 1 1 1725 MTR302 200 240 346 415 50 3 1 2 37 2 0 1 0 1425 MTR302 220 380 60 3 1 2 37 1 8 0 9 1725 Note All motors have built in thermal overload protection ...

Страница 15: ...uld be removed daily or as required to prevent an over accumulation Permanent press durable press and other modern day fabrics require the care that your laundry dryers now provide At the end of the drying cycle a timed cool down control automatically takes over and continues the rotation of the fan and basket without heat until the garment load reaches a safe cool temperature This function is per...

Страница 16: ...rvice connection box on the rear of the dryer Do not change wiring without consulting factory as you may void the factory warranty Do not connect the dryer to any voltage or current other than that specified on the dryer rating plate Wiring diagram is located on rear wall of dryer ELECTRICAL CONTROLS SERVICING Caution Label all wires prior to disconnection when servicing controls Wiring errors can...

Страница 17: ... line If gravity return to boiler omit trap 3 Insulate steam supply and return line for safety of operator and safety while servicing dryer 4 Keep dryer in good working condition Repair or replace any worn or defective parts 1 Keep steam coils clean 2 Check periodically and clean as often as required 3 Remove lint and dirt accumulation from coil fins periodically as dirty lint laden coil fins decr...

Страница 18: ... Check the altitude of dryer 4 Check with utilities company for proper gas pressure and gas supply line 5 Natural gas only check the gas pressure inlet supply to dryer 11 inches 27 mbar water column maximum Manifold pressure 3 5 inches 8 7 mbar water column pressure 6 L P gas only manifold pressure 13 inches 32 mbar watercolumnmaximum CAUTION Lowgaspressureandintermittentgaswillcause gasignitionpr...

Страница 19: ...y piping system during any pressure testing of that system at test pressures in excess of 1 2 psi 3 5 kPa The dryer must be isolated from the gas supply piping system by closing it s individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psi 3 5 kPa ...

Страница 20: ...ances should be connected upstream from the loop WARNING LIQUIFIEDPETROLEUMGASESONLY A gas pressure regulator for liquified petroleum gases is not furnished on gas heated clothes dryers This regulator is normally furnished by the installer In accordance with American Gas Association AGA standards a gas pressure regulator when installed indoors must be equipped with a vent limiter or a vent line mu...

Страница 21: ...300000 330000 350000 380000 400000 430000 450000 480000 504000 550000 605000 650000 705000 750000 806000 850000 907000 960000 1000000 3 4 3 4 3 4 3 4 3 4 3 4 1 1 1 1 1 4 1 1 4 1 1 2 1 1 2 1 1 2 2 2 2 2 2 2 2 2 2 2 1 2 2 1 2 2 1 2 2 1 2 2 1 2 2 1 2 2 1 2 2 1 2 3 3 3 3 3 3 4 3 4 3 4 1 1 1 1 1 1 1 4 1 1 4 1 1 2 1 1 2 2 2 2 2 2 2 2 1 2 2 1 2 2 1 2 2 1 2 2 1 2 2 1 2 2 1 2 2 1 2 3 3 3 3 3 3 3 1 2 3 1 2 ...

Страница 22: ...rn line it is recommended that each have a 3 4 DN 20 union and 3 4 DN 20 globe valve This will enable you to disconnect the steam connections and service the dryer while your plant is in operation 5 Before connecting trap and check valve to dryer open globe valve in steam supply line and allow steam to flow through dryer to flush out any dirt and scale from dryer This will assure proper operation ...

Страница 23: ...Page 23 Steam Piping Installation Illustration ...

Страница 24: ...6US30 L36US36 L44FD42 MODELS L28CD30 L28UR30 L36CD30 L36UR30 L36UR36 L36AR36 L44FD42 MODELS L44CD42 L50CD42 No of dryers Duct diameter in inches in cm No of dryers Duct diameter in inches in cm No of dryers Duct diameter in inches in cm 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 6 9 11 12 14 15 16 17 18 19 20 21 22 23 23 24 25 26 26 27 28 28 29 30 15 23 27 30 35 38 41 43 46 48 ...

Страница 25: ...minute cfm used 4 Zero inches clearance to combustible material allowed on sides and at points within 4 inches 100 mm of front on top 5 Heat loss into laundry room from dryer fronts only is about 60 Btu h per square foot 15 kcal h per 0 1m 6 Flange mounted belt driven tube axial fan Fan must run when one or more dryers are running See suggested Automatic Electrical Control Wiring Diagram on previo...

Страница 26: ... enclosure from the top or side walls See Dryer Make up Air Requirements Chart 2 Enclosure plenum with service door This separates the dryer air from the room comfort air If dryers use room air instead of outside air additional heat loss can be another 25 Btu h 6 3 kcal h for each cubic foot per minute cfm 1 8 m h used 3 Zero inches mm clearance to combustible material allowed on sides and at poin...

Страница 27: ...2 C 125 125 56 7 2000 3400 12 305 384 2477 C 150 150 68 2250 3825 12 305 432 2787 HD175 175 79 4 2780 4726 12 305 534 3445 HD190 190 86 2 3000 5100 12 305 576 3716 WMC HD20 20 9 1 450 765 6 153 87 561 WMC HD30 30 13 6 625 1063 8 203 120 774 WMC HD50 50 22 7 700 1190 8 203 135 871 WMC HD75 75 34 750 1275 8 203 144 929 Notes 1 The Model C 30 ST has 2 pockets per dryer each pocket has the above liste...

Страница 28: ...Use 2 feet 0 6 m of straight duct on dryer before installing an elbow on Energy Saver models only 5 Do not install wire mesh or other restrictions in the exhaust duct 6 Use clean outs in the exhaust duct and clean periodically when needed 7 Never exceed 0 3 inches 7 6 mm water column static pressure in the exhaust duct 8 Inside surface of the duct must be smooth 9 Recommend pop rivets for duct ass...

Страница 29: ...warnings or precautions 7 Never tumble fiberglass materials in the dryer unless the labels say they are machine dryable Glass fibers break and can remain in the dryer and could cause skin irritation if they become mixed into other fabrics 8 Reference Lighting and shut down instructions and wiring diagrams are located on the rear wall of the dryer cabinet 9 The dryer must not be installed or stored...

Страница 30: ...rature heavy fabrics and hard to dry cottons and linens MEDIUM 150 F 66 C exhaust temperature permanent press synthetic blends LOW 135 F 57 C exhaust temperature delicate sheer fabrics 4 Press the Start button to start the drying and cooling cycles OPERATING INSTRUCTIONS COIN METER MODELS WHAT IS HAPPENING AFTER STEP 4 1 Digital Display will count down time remaining in cycle Computerized Coin Met...

Страница 31: ...ryerisdesignedforacapacitymaximumload Overloading itwillresultinlongerdryingtimeanddampspotsonsomeofthe load Maximumoperatingefficiencydependsonproperairflow The lint screen must be kept clean daily to insure proper circulation of air throughout the dryer Thiscommercialdryerhaskeysforthelintdoorandaccessdoor to burners and controls This is for the safety of the user IMPORTANT ...

Страница 32: ...Page 32 Setting Time On Computerized Coin Meter Illustration COMPUTERIZED COIN METER DIP Switch Banks are located here ...

Страница 33: ...ime minutes asshown 3 To set the time on the DIP bank simply set the appropriate switch to the ON up position to total the desired amount of time NOTE OFF down position equals 0 minute EXAMPLE 25 for12minutes MINUTES 0 0 4 8 12 min Setting Time On Computerized Coin Meter ON 1min 2min 4min 8min OFF INSTRUCTIONS FOR SETTING TIME ON COMPUTERIZED COIN METER ...

Страница 34: ... main gas line turned on 3 Check for low or intermittant gas pressure 4 Check spark ignition module diagnostic light CLOTHES ARE NOT SATISFACTORILY DRY 1 Timed cycle Did you allow enough heating time before the cool down part of the cycle 2 Is the lint screen blocked 3 Is the exhaust duct to the outside clean and not blocked A blocked exhaust will cause slow drying and other problems GASDRYERIGNIT...

Страница 35: ...heck with local power company for recommended corrective measures Check with local power company to insure that wiring is adequately sized for load Check all electrical connections and tighten any loose connections Check installation sheet for recommended make up air openings Clean lint accumulation on and around motors Replace timer Replace V belt Adjust belt tension Tighten set screw Remove load...

Страница 36: ...jects lint accumulation or other causes that may prevent damper from opening Check duct work for lint build up Check installa tion sheet to insure that duct work and make up air openings are adequately sized Check exhaust outlet If a screen has been improperly installed on the outlet it may be clogged with lint or frozen over in winter NEVER install a screen on the exhaust outlet Vacuum within dry...

Страница 37: ...r Open for blue flame Blow out Adjust gas pressure per rating plate Send to factory for correct orifices Clean exhaust Replace direct spark igniter Replace orifices Check factory for correct size Dryer runs but no heat continued Main burners burning improperly Main burner cycles on and off Low or high gas flame Air switch out of adjustment Air switch defective Gas pressure too low Improper orifice...

Страница 38: ...thermostat controls operation of solenoid valve If defective replace thermostat Check for inlet and outlet marking on check valve and invert if necessary Remove plug and blow down strainer or remove and clean thoroughly if heavily clogged Check piping per steam installation instructions Check trap for size and capacity If dirty and sluggish clean thoroughly or replace Check return line for high ba...

Страница 39: ...f the module has multiple retries and no flame is detected the gas valve is de energized and the module goes into an interpurge delay After this delay the module will attempt another trial for the ignition period This will continue until the number of retries has been used up At the time the module will go into safety lockout 4 Recovery from safety lockout requires one of the following a A manual ...

Страница 40: ...Page 40 DIRECTSPARK IGNITIONOPERATION FLOW CHART ...

Страница 41: ...f idler bracket Lubricate idler pulley once every two months using six grams of high temperature grease Do not over grease 5 Electric motor Keep motor clean and dry Motors are packed with sufficient grease for 10 years normal service After that bearings and housing should be cleaned and repacked one third full with Chevron grease No SR1 2 See label on motor for further information If motor overhea...

Страница 42: ...ame by following instructions outlined on separate page of this manual 12 Main Basket Bearings Lubricate once every six months using six grams of high temperature grease Do not over grease 13 Steam Heating Units Keep steam coils clean Check periodically and clean as often as required Remove lint and dirt accumulation from coil fins to avoid decreasing their efficiency 14 CleanOutPanel EnergySaverG...

Страница 43: ...ET TYPE OF GAS SHUTTER ADJUSTMENT Natural gas 1 2 Open Liquidpetroleum 1 4 Open Manufacturedgas 1 16 Open AIR SHUTTER ADJUSTMENT ProperMethod Close air shutters to yellow tip then open air shutters to blue flame tip Orange tips are impurities in the air such as lint dust etc CORRECT BURNER AIR INLET SHUTTER ADJUSTMENT AIR SHUTTER ADJUSTMENT ...

Страница 44: ...ner air inlet shutters are correctly adjusted but air through the dryer is insufficient This condition indicates excessive lint in the lint compartment lack of make up air in the room restricted exhaust duct or a vacuum in the room caused byanexhaustfan WRONG NEED TO PROVIDE CORRECT AIRFLOW THROUGH THE DRYER Burner Air Inlet Shutter Adjustment BURNER AIR INLET SHUTTER ADJUSTMENT BURNER AIR INLET S...

Страница 45: ...aft Step 4 Remove the nuts and washers holding the flange basket bearing and take it off the dryer Step 5 Inspect the bearings for damage and replace as necessary in reverse order of removing them Before tightening securely align basket per instructions on separate instruction sheet Step 6 Lubrication guide Bearings never need lubrication They have been permanently lubricated by the supplier with ...

Страница 46: ...B diameter pins inside the drying compartment between the rim of the basket opening and the rim of the door opening in the positions shown in figures 1 and 2 Check the two B pins for equal clearance NOTE Push the basket toward the rear Step 4 With the pins in position tighten the set screws on the bearing races Step 5 Tighten the side bolts 1 2 3 4 in numerical order Tighten the bolts 7 on the pil...

Страница 47: ...aping the sweep sheet C Mark this position and the nearest rib to this position D Remove the basket do not loosen the alignment bolts E With the basket on the floor spider up place one or two shims between the spider leg and the back of the basket at the marked rib position See drawing F Re insert spider and basket assembly and re check cylinder G If at this point basket is still out of round proc...

Страница 48: ...osition shown hold switch mounting bracket firmly and adjust switch actuator D with needle nose pliers at E by twisting actuator right or left whichever is needed so that switch closes when end of air blade engages bar C 4 Maximum opening of air switch must be no greater than 3 4 FIGURE 3 Bend tab F in or out to maintain this dimension 5 Re install air switch assembly on rear of dryer 6 Re check o...

Страница 49: ...Page 49 30 lb Dryer Front View Illustration ...

Страница 50: ...lacement Kit 25 TU10284 Lint Trap Front Support 26 TU10177 Spacer 27 TU8457 Thermostat Cover 28 TU9225 Coin Vault Lock and Key 29 TU14602 Front Panel and Door Assembly Specify Color 30 TU2083 Basket Welded Assembly TU7188 Basket Spider Assembly 31 TU2883 1 2 Cut Washer 32 TU2313 Tie Rod 33 GA 00765 0 Direct Spark Igniter TU14176 CE Direct Spark Igniter TU14675 Australian Direct Spark Igniter 34 TU...

Страница 51: ...Page 51 30 lb Dryer Rear View Illustration ...

Страница 52: ...d 1 TU7733 8 x 1 2 Self Drill Screw 2 TU3211 3 8 16 x 2 1 2 Leveling Bolts 3 TU4937 3 8 16 Jam Nut 5 TU4787 3 8 16 Hex Nut 6 VSB134 3 8 Split Lockwasher 7 TU12803 Idler Bracket 8 TU12576 3 8 16 x 1 Carriage Bolt 9 TU3247 Retaining Ring 10 TU7184 Sleeve Bearings 2 required 11 TU5217 14 Idler Sheave 50 60 Cy 12 TU3395 V Belt 4L580 50 Hz TU7021 V Belt 4L570 60 Hz 13 TU3395 V Belt 4L580 50 60 Hz 14 TU...

Страница 53: ...ontrol 37 SB 00951 0 Screw 8 x 7 16 Phillips 38 CA 13098 0 Gasket Access Door Not Shown 1 TU14662 Logo Decal 2 TU3479 10 32 x 7 16 Truss Head Screw 3 P104 1 4 Cut Washer 4 FB187 10 Lockwasher 5 TU2842 10 32 Hex Nut 6 TU14568WHT Access Door W A Specify Color 7 TU9386 Lock JWC3 7A TU8995 Cam 8 TU9387 Key JWC3 9 F1300 Motor Relay 10 Coin Rejector Specify Coin Number and Denomination TU9006 Rejector S...

Страница 54: ...6 TU3266 Nut 27 SV136 6 32 x 15 16 Truss Head Scr 28 M271 8 Int Tooth Lockwasher 29 SB 00951 0 Screw 8 x 7 16 Phillips 30 CA 13098 0 Gasket Access Door Not Shown Call factory for Coin Meter part number for 50 Cy 1 TU14568WHT Access Door Weldment Specify Color 2 TU3479 10 32 x 7 16 Truss Head Screw 3 P104 1 4 Cut Washer 4 TU2842 10 32 Hex Nut 5 TU9386 Lock JWC3 5A TU8995 Cam 6 TU9387 Key JWC3 7 TU1...

Страница 55: ...8 TU2878 10 x 5 8 Sheet Metal Screw 9 TU5158 Door Catch Assembly 10 TU2236 Hinge Post 11 PIF172 Delrin Bearing Pkg 2 12 TU2090 Basket Door Seal 13 TU4839 10 32 x 3 8 Machine Screw 14 TU7862 Door GLass Plain TU7862C Door Glass w Logo 15 TU7171 Basket Door Specify Color 16 TU3215 10 32 x 3 8 Taptite Screw 18 TU2874 Basket Door Handle 19 TU7169 Rubber Gasket NOTE TU4827 Actuator Assembly Consists of ...

Страница 56: ...U3240 SafetyHighLimitThermostat 2 TU3240 185 F 85 C Thermostat 3 TU5150 150 F 66 C Thermostat 4 TU7244 135 F 57 C Thermostat 5 TU5143 MountingBracket 6 TU3624 6 32 x 1 4 Round Head Screw 6 each 7 TU3400 6 32 Hex Nut 8 TU7733 8 x 1 2 Self Drill Screw 9 TU6067 8 Speed Clip 2 each ...

Страница 57: ...ll Screw 2 TU8052 Tee 8 x 6 x 6 3 TU8176 Pipe 8 x 17 1 2 4 TU9161 Installation Label 5 TU10268 Elbow 8 6 TU10335 Tee 8 x 6 x 6 7 TU8053 Elbow 6 8 TU8054 Pipe 6 x 15 1 2 9 TU8055 Pipe 6 x 23 1 2 1 F888 E Ring 2 TU2463 Actuator Arm 3 TU3476 Air Switch Decal 4 TU1771 6 Tinnerman Nut 5 TU8155 Air Switch 6 TU1770 Insulator 7 TU8171 Air Switch Bracket 8 TU7733 8 18 1 2 Self Drilling Screw 9 TU3219 6 x 1...

Страница 58: ...ld 5 TU2414 3 4 16 x 3 8 Straight Connector 6 TU2405 Steam Coil 9 required 7 3 4 W x 1 5 8 H x 26 L 7 CB36 1 4 20 x 1 2 Hex Head Screw Pkg of 6 8 TU7733 8 x 1 2 S M S Pkg of 6 9 TU2598 Air Filter 16 x 25 x 1 10 TU2735 1 x 3 4 Reducer 11 TU4608 3 4 x 2 Pipe Nipple 12 TU13517 Solenoid Valve 24V 50 60 Hz 13 CFB2100 Greenfield Cable 1 2 Specify 21 Long 14 TU4790 1 2 Straight Conn 2 required 15 TU10651...

Страница 59: ...t 8 TU10946 Manifold Plug 9 TU13678 Thermostat Man Reset 300º 10 390501053 1 2 Elbow 11 GA 00764 0 Electrode Spark Igniter 12 CB36 1 4 20 x 1 2 Hex Hd Scr 13 TU2846 1 4 Split Lockwasher 14 TU4934 1 4 20 Hex Nut 15 TU2847 1 4 Flat Washer 16 TU2224 1 8 Pipe Plug 17 TU3539 Gas Burner Orifice specify size 18 TU8288 Manifold Assembly 19 TU7840 Burner 20 TU13826 Electrode Spark Mounting Bracket 21 TU864...

Страница 60: ... GA 00764 0 Electrode Spark Igniter 11 TU13826 Electrode Spark Mounting Plate 12 CB36 1 4 20 x 1 2 Hex Head Screw 13 TU2846 1 4 Split Lockwasher 14 TU2847 1 4 Flat Washer 15 TU4934 1 4 20 Hex Nut 16 TU2224 1 8 Pipe Plug 17 TU3539 Gas Burner Orifice specify size 18 TU7840 Burner 19 TU8288 Manifold Assembly 20 TU10946 Manifold Plug 21 TU2877 10 Tinnerman Nut 22 TU2878 10 x 5 8 S M S 23 TU3479 10 32 ...

Страница 61: ...Block D Fuse E Bonnet with Elements F Heater Elements G Motor Fuse 1 TU3103 Bonnet Weldment 2 TU3102 Hold Down Plate 3 TU9205 Control Box Weldment 4 TU9207 Terminal Box Cover 5 TU12454 Top Cover 7 TU3104 Air Inlet Cover 8 TU3767 Contact Strap 4 required 9 TU3768 Contact Strap 1 required 10 TU3253 Insulators 11 TU13866 Fuse Holder 12 TU7738 Grounding Lug 13 TU9254 High Voltage Label for 415V Only 1...

Страница 62: ...U9143 TU9143 TU9143 TU9142 TU9143 TU9143 TU9143 TU9142 D HeaterFuse Block TU11096 TU11096 TU11096 TU11096 TU9141 TU11096 TU11096 TU11096 TU11096 E HeaterFuses TU7224 40AMPS 3required TU7224 40AMPS 3required TU7224 40AMPS 3required TU7224 40AMPS 3required TU7072 40AMPS 3required TU7224 40AMPS 3required TU7224 40AMPS 3required TU7224 40AMPS 3required TU7224 40AMPS 3required F Bonnetwith Elements TU7...

Страница 63: ...KW 480V 3PH 21KW 240 414 3PH 21KW 550V 3PH Heater Amperes Motor Amperes Control Amperes Total Amperes at Rated Voltage 109 AMPS 66 AMPS 62 AMPS 95 AMPS 59 AMPS 55 AMPS 28 AMPS 55 AMPS 25 AMPS Hz 60 60 60 60 60 60 60 50 60 Minimum Size Supply Wire Based On 60C 140ºF Insulated Copper Conductor 1AWG 4AWG 4AWG 1AWG 4AWG 4AWG 10AWG 4AWG 10AWG Circuit Minimum Conduit Trade Size 1 1 2 1 1 4 1 1 4 1 1 2 1...

Страница 64: ...Page 64 ...

Отзывы: