Washer-Extractors

10

5-08-53

Installation - Models IHF033, IHF045 
and IHF055

Ground

The machine must be placed on a flat, solid surface 

(metal base, concrete or solid ground). It is 

recommended that the machine be anchored on the 

provided places (1) in the base, especially in case of a 

plinth. Refer to 

Figure 6

.

Figure 6 

The machine must be placed entirely level. For easy 

maintenance it is recommended to keep a minimal 

distance of 23.62 in. (600 mm) between the wall and 

the back of the machine.
If several machines are placed next to each other, there 

should be a minimal distance of 1.18 in. (30 mm) 

between each machine.

Electrical Installation Requirements 
- Models IHF033, IHF045 and IHF055

Table 1 

CHM2180N

1

Mounting Bolt Holes

1

Machine with steam heating or boiler fed 

machines without additional electrical heating

220V 3AC

380V 3AC + N

16 A

16 A

Machine with electrical heating

220V 3AC

380V 3AC + N

9 kW

25 A

16 A

12 kW

40 A

20 A

15 kW

50 A

25 A

18 kW

50 A

32 A

21 kW

N/A

40 A

24 kW

N/A

40 A

Содержание CHM2172N

Страница 1: ...5 08 53R2 June 2011 Refer to Installation manual for full instructions On Premise Laundry Planning Handbook IHF Washer Extractors CHM2172N ...

Страница 2: ...s 2 Introduction 2 Model Identification IHF Washer Extractors 2 Specifications and Dimensions Model IHF033 3 Specifications and Dimensions Model IHF045 5 Specifications and Dimensions Model IHF055 7 Installation Models IHF033 IHF045 and IHF055 10 Specifications and Dimensions Model IHF075 11 Installation Model IHF075 14 Specifications and Dimensions Model IHF100 15 Specifications and Dimensions Mo...

Страница 3: ...ight Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 2 5 08 53 Washer Extractors Introduction Model Identification IHF Washer Extractors Figure 1 CHM2172N IHF033 IHF075 IHF165 IHF045 IHF100 IHF055 IHF135 ...

Страница 4: ...eight of door center above floor in mm 30 34 770 Speed Wash 10 50 tr min RPM Distribution 85 tr min RPM Low Spin 250 500 tr min RPM High Spin 500 1000 tr min RPM G factor Low Spin High Spin 94 380 Motor 3 phase 4p 1470 tr min 2 95 HP 2 2 kW Drain Valve in mm 2 51 Water Supply hard soft warm water in mm 75 19 Direct Steam Heating Steam inlet connection size in mm 38 10 Heating Electrical Heating 23...

Страница 5: ...Dispenser 6 Ventilation Tub Figure 2 CHM2173N CHM2174N 54 15 in 1375 5 mm 53 07 in 1348 mm 1 34 in 34 mm 8 66 in 220 mm 26 77 in 680 mm 1 97 in 50 mm 22 24 in 565 mm 30 71 in 780 mm 3 41 in 86 5 mm 26 18 in 665 mm 29 65 in 753 mm 28 86 in 733 mm CHM2174N CHM2173N CHM2175N 6 10 in 155 mm 7 95 in 202 mm 7 87 in 200 mm 44 94 in 1141 5 mm 36 81 in 935 mm 41 99 in 1066 5 mm 27 70 in 703 5 mm 6 69 in 17...

Страница 6: ...ght of door center above floor in mm 30 34 770 Speed Wash 10 50 tr min RPM Distribution 85 tr min RPM Low Spin 250 500 tr min RPM High Spin 500 1000 tr min RPM G factor Low Spin High Spin 94 380 Motor 3 phase 4p 1470 tr min 2 95 HP 2 2 kW Drain Valve in mm 2 51 Water Supply hard soft warm water in mm 75 19 Direct Steam Heating Steam inlet connection size in mm 38 10 Heating Electrical Heating 230 ...

Страница 7: ...Dispenser 6 Ventilation Tub Figure 3 CHM2173N CHM2174N 54 15 in 1375 5 mm 53 07 in 1348 mm 1 34 in 34 mm 8 66 in 220 mm 26 77 in 680 mm 1 97 in 50 mm 22 24 in 565 mm 30 71 in 780 mm 3 41 in 86 5 mm 30 12 in 765 mm 33 58 in 853 mm 32 80 in 833 mm CHM2174N CHM2173N CHM2175N 6 10 in 155 mm 7 95 in 202 mm 7 87 in 200 mm 44 94 in 1141 5 mm 36 81 in 935 mm 41 99 in 1066 5 mm 27 70 in 703 5 mm 6 69 in 17...

Страница 8: ...8 630 Height of door center above floor in mm 32 28 820 Speed Wash 10 50 tr min RPM Distribution 100 tr min RPM Low Spin 250 500 tr min RPM High Spin 500 1000 tr min RPM G factor Low Spin High Spin 74 373 Motor 3 phase 4p 1470 tr min 4 08 HP 3 0 kW Drain Valve in mm 3 76 Water Supply hard soft warm water in mm 75 19 Direct Steam Heating Steam inlet connection size in mm 5 13 Heating Electrical Hea...

Страница 9: ...ilation Soap Dispenser 6 Ventilation Tub Figure 4 CHM2178N CHM2176N CHM2177N 60 14 in 1527 5 mm 59 06 in 1500 mm 1 38 in 35 mm 9 45 in 240 mm 29 06 in 738 mm 3 19 in 81 mm 25 39 in 645 mm 35 43 in 900 mm 2 76 in 70 mm 32 68 in 830 mm 36 99 in 939 5 mm 36 46 in 926 mm CHM2177N CHM2176N CHM2178N 3 70 in 94 mm 6 12 in 155 5 mm 6 81 in 173 mm 54 57 in 1386 mm 49 82 in 1265 5 mm 28 35 in 720 mm 4 13 in...

Страница 10: ...DO NOT COPY or TRANSMIT Washer Extractors 5 08 53 9 Mounting Bolt Hole Locations Model IHF055 CHM2179N Figure 5 CHM2179N 3 19 in 81 mm 29 06 in 738 mm 1 73 in 44 mm 36 57 in 929 mm 32 68 in 830 mm 2 36 in 60 mm 35 43 in 900 mm 43 7 in 1110 mm ...

Страница 11: ...easy maintenance it is recommended to keep a minimal distance of 23 62 in 600 mm between the wall and the back of the machine If several machines are placed next to each other there should be a minimal distance of 1 18 in 30 mm between each machine Electrical Installation Requirements Models IHF033 IHF045 and IHF055 Table 1 CHM2180N 1 Mounting Bolt Holes 1 Machine with steam heating or boiler fed ...

Страница 12: ...enter above floor in mm 32 28 820 Speed Wash 10 50 tr min RPM Distribution 100 tr min RPM Low Spin 250 500 tr min RPM High Spin 500 1000 tr min RPM G factor Low Spin 84 High Spin 383 Motor 3 phase 4p 1470 tr min 5 36 HP 4 0 kW Drain Valve in mm Depend O Drain 3 76 Option 2 51 Water Supply hard soft hot water cool down in mm 75 19 Direct Steam Heating Steam inlet connection size in mm 5 13 Electric...

Страница 13: ...Warm Water Connections 75 in 7 Water Drain 4 Soft Water Connections 75 in 8 Steam Connection CHM2183N CHM2181N CHM2182N 60 24 in 1530 mm 5 71 in 145 mm 42 52 in 1080 mm 34 25 in 870 mm 24 80 in 630 mm 41 73 in 1060 mm 2 56 in 65 mm 37 80 in 960 mm CHM2182N CHM2181N 7 87 in 200 mm 5 91 in 150 mm 32 28 in 820 mm 1 38 in 35 mm 22 83 in 580 mm 3 15 in 80 mm 11 02 in 280 mm 11 42 in 290 mm 1 2 4 6 3 7 ...

Страница 14: ...NOT COPY or TRANSMIT Washer Extractors 5 08 53 13 Mounting Bolt Hole Locations Model IHF075 CHM2179N Figure 8 CHM2179N 3 84 in 97 5 mm 34 06 in 865 mm 1 38 in 35 mm 41 73 in 1060 mm 37 8 in 960 mm 2 56 in 65 mm 41 73 in 1060 mm 50 87 in 1292 mm ...

Страница 15: ...irely level For easy maintenance it is recommended to keep a minimal distance of 23 62 in 600 mm between the wall and the back of the machine If several machines are placed next to each other there should be a minimal distance of 1 18 in 30 mm between each machine Electrical Installation Requirements Model IHC075 Table 2 CHM2180N 1 Mounting Bolt Holes 1 Machine with steam heating or boiler fed mac...

Страница 16: ...ve floor in mm 39 37 1000 Speed Wash 10 50 tr min RPM Distribution 100 tr min RPM Spin 250 400 tr min RPM High Spin 500 800 tr min RPM G factor Spin 87 High Spin 350 Motor 3 phase 4p 1470 tr min 10 05 HP 7 5 kW Drain Valve in mm 3 76 Water Supply hard soft hot water in mm 75 19 Direct Steam Heating Steam inlet connection size in mm 5 13 Electrical Electrical Heating 220 380 V 27 kW Electrical Heat...

Страница 17: ...in 5 Steam Connection 5 in 10 Connection of the Liquid Soap Hoses CHM2186N CHM2187N 75 59 in 1920 mm 52 56 in 1335 mm 40 94 in 1040 mm 37 80 in 960 mm 47 24 in 1200 mm 4 53 in 115 mm 4 33 in 110 mm 39 76 in 1010 mm CHM2187N CHM2186N CHM2188N 12 01 in 305 mm 8 46 in 215 mm 9 25 in 235 mm 27 36 in 695 mm 7 28 in 185 mm 2 17 in 55 mm 1 97 in 50 mm 1 3 9 5 4 10 6 8 86 in 225 mm 6 89 in 175 mm 4 53 in ...

Страница 18: ...OT COPY or TRANSMIT Washer Extractors 5 08 53 17 Mounting Bolt Hole Locations Model IHF100 CHM2179N Figure 11 CHM2179N 3 19 in 81 mm 40 87 in 1038 mm 1 73 in 44 mm 44 33 in 1126 mm 46 65 in 1012 mm 2 76 in 70 mm 47 24 in 1200 mm 57 09 in 1450 mm ...

Страница 19: ... floor in mm 39 37 1000 Speed Wash 10 50 tr min RPM Distribution 100 tr min RPM Spin 250 400 tr min RPM High Spin 500 800 tr min RPM G factor Spin 87 High Spin 350 Motor 3 phase 4p 1470 tr min 10 05 HP 7 5 kW Drain Valve in mm 3 76 Water Supply hard soft hot water in mm 75 19 Direct Steam Heating Steam inlet connection size in mm 5 13 Electrical Electrical Heating 220 380 V 27 kW Electrical Heatin...

Страница 20: ...in 5 Steam Connection 5 in 10 Connection of the Liquid Soap Hoses CHM2186N CHM2187N 75 59 in 1920 mm 59 06 in 1500 mm 40 94 in 1040 mm 37 80 in 960 mm 47 24 in 1200 mm 4 53 in 115 mm 4 33 in 110 mm 46 65 in 1185 mm CHM2187N CHM2186N CHM2188N 12 01 in 305 mm 8 46 in 215 mm 9 25 in 235 mm 27 36 in 695 mm 7 28 in 185 mm 2 17 in 55 mm 1 97 in 50 mm 1 3 9 5 4 10 6 8 86 in 225 mm 6 89 in 175 mm 4 53 in ...

Страница 21: ...OT COPY or TRANSMIT Washer Extractors 20 5 08 53 Mounting Bolt Hole Locations Model IHF135 CHM2179N Figure 13 CHM2179N 3 19 in 81 mm 40 87 in 1038 mm 1 73 in 44 mm 51 02 in 1296 mm 46 65 in 1185 mm 2 76 in 70 mm 47 24 in 1200 mm 61 92 in 1573 mm ...

Страница 22: ...e 14 Figure 14 The machine must be placed entirely level For easy maintenance it is recommended to keep a minimal distance of 23 62 in 600 mm between the wall and the back of the machine If several machines are placed next to each other there should be a minimal distance of 1 18 in 30 mm between each machine Electrical Installation Requirements Models IHF100 and IHF135 Table 3 CHM2180N 1 Mounting ...

Страница 23: ...tom above floor in mm 27 95 710 Height of door center above floor in mm 40 16 1020 Speed Wash 10 50 tr min RPM Distribution 100 tr min RPM Spin 250 750 tr min RPM G factor Spin 344 Motor 3 phase 4p 1470 tr min 15 42 HP 11 5 kW Drain Valve in mm 3 76 Water Supply hard soft hot water in mm 1 25 Direct Steam Heating Steam inlet connection size in mm 75 19 Electrical Electrical Heating 240 V 27 kW Ele...

Страница 24: ...team Connection 11 Input Liquid Soap 6 Water Drain CHM2197N CHM2196N CHM2195N 82 68 in 2100 mm 63 78 in 1620 mm 44 88 in 1140 mm 40 16 in 1020 mm 51 18 in 1300 mm 46 65 in 1185 mm CHM2196N CHM2195N CHM2197N 4 53 in 115 mm 27 95 in 710 mm 13 19 in 335 mm 10 04 in 255 mm 9 65 in 245 mm 27 36 in 695 mm 7 28 in 185 mm 2 17 in 55 mm 1 97 in 50 mm 1 3 5 2 2 11 6 2 8 86 in 225 mm 6 89 in 175 mm 4 53 in 1...

Страница 25: ...PY or TRANSMIT Washer Extractors 24 5 08 53 Figure 15 Mounting Bolt Hole Locations Model IHF165 CHM2179N Figure 16 CHM2179N 3 19 in 81 mm 44 80 in 1138 mm 1 73 in 44 mm 51 14 in 1299 mm 46 65 in 1185 mm 2 76 in 70 mm 51 18 in 1300 mm 64 72 in 1644 mm ...

Страница 26: ...s Refer to Figure 17 Figure 17 The machine must be placed entirely level For easy maintenance it is recommended to keep a minimal distance of 23 62 in 600 mm between the wall and the back of the machine If several machines are placed next to each other there should be a minimal distance of 1 18 in 30 mm between each machine Electrical Installation Requirements Model IHF165 Table 4 CHM2180N 1 Mount...

Отзывы: