Power Backup (UPS)
As with any server, a steady supply of clean power is essential for TimeIPS.
•
Losing power while the server is operating may cause data loss or
corruption.
•
Brown-outs or flickering power can cause damage to the power supply
and/or system components.
To prevent damage and/or data loss related to power problems, we recommend
plugging the TimeIPS server into a UPS (Uninterruptible Power Supply).
TimeIPS servers are relatively low-power devices . A UPS with a minimum rating
of 700VA is recommended for maximum power stability and moderate run-time.
TimeIPS servers have support for communicating with most APC brand Smart-UPS
units with USB data cables. The signals from these UPS units allow TimeIPS to log
and report power outages and perform a clean automated shutdown in the event of
an extended outage. This will protect your data and is highly recommended.