Series number checking method: turn” OUTLET NO.1" knob to “U” on the panel and press the RESET 

button, then the digital tube will show the series number after the baud rate “9600”. The series number is 

made up of six numbers, letters or number-letter combinations. 

4.

 

According to working environment to configure the TPD-800A network: open the menu of "Network" to 

set the network address required. Make sure the TPD-800A new IP must be in the same network segment with 

the original IP of your PC. Submit and save after confirmation. This configuration will come into force after 

software restart.   

 

6.

 

Return to the original PC network configuration

.                                                   

 

 

 

Содержание TPD-800A

Страница 1: ...uration 1 Checking the devices and accessories first one set of TPD 800A and one piece of network cable 2 Set up the TPD 800A as Master M S indicator on means the TPD 800A is Master M S indicator off means the TPD 800A is slave Master Setting Method Press Reset button on the device for 12 seconds the interval of RUN light is 2 seconds Setting is successful when the M S indicator is on Slave Settin...

Страница 2: ...nd Figure 2 Through HUB Ⅱ Software Configuration User login Opening IE browser support IE 6 0 7 0 and 8 0 versions other browsers except IE are not available currently Default IP address is 192 168 1 163 and default Login Name is adm Password is adm Please note that the login name and password are all Lower case letter Please see details as following 1 M S Master or Slave status 2 RUN Operating st...

Страница 3: ...nged PC IP address and the default device IP address are in the same network segment For instance set the PC IP address to be 192 168 1 X X can be 0 to 255 except 163 the Sub net Mask 255 255 255 0 the default gateway 192 168 1 1 As shown in the following 3 Log on to the user administration interface through IP 192 168 1 163 with the default login name and password ...

Страница 4: ...WER TPD 800A Quick Installation Guide 3 Click on and open the Device Configuration interface enter the device series number that is a unique one which could be viewed on the LED screen of the device panel ...

Страница 5: ...made up of six numbers letters or number letter combinations 4 According to working environment to configure the TPD 800A network open the menu of Network to set the network address required Make sure the TPD 800A new IP must be in the same network segment with the original IP of your PC Submit and save after confirmation This configuration will come into force after software restart 6 Return to t...

Страница 6: ...OWER TPD 800A Quick Installation Guide 7 Connect TPD 800A and PC to WAN and access TPD 800A with the new IP configured TPD 800A also support SNMP SSH and Telnet management Details refer to the User Manual ...