8.1 Pairing Issues
1. Check the signal strength on the LED display at the Host and Client IPmitter.
Please see page 33 for different sites effecting the range.
2. Check the SYS light at the Host and Client IPmitter > If the SYS light is not lit then
check your 48V PoE source or 12V DC source.
3. Check the WAN or LAN indicator Host and Client IPmitter > This will light up if a
device connected and powered correctly. Please note this may not just be a power
issue for the device connected but the cable connecting the IPmitter and the devices
may be wired incorrectly or have a fault.
8.2 Signal strength of P-095
1. Check the pairing > The signal strength of P-095 shows they have not paired up
correctly. Reset both IPmitters, holding the R (reset) button down on both IPmitters for
10 seconds. Once both units have booted back up, then try the pairing process
again.
2. Between P-070 and P-095 is too low for transmission > Try the pairing process
with the devices closer together.
8.3 IP camera not working through IPmitter
1. Check the IP Camera works fine without the IPmitter > This ensures the setup for
your NVR/ network has the correct settings, set up a test network via a switch
plugged into your NVR/ network.
2. Check the LED displays on both IPmitters > see Pairing Issues
3. Check signal strength of the IPmitters > see Signal strength of P-095
3. Ensure your IP Camera is powered and connected.
4. Check IP address settings, your IP Cameras needs match your NVR/ network.